Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion model

A novel technique is presented which enables the calibration of a 3D affine respiratory motion model to the individual motion pattern of the patient. The concept of multiple navigators and precursory navigators is introduced to address nonlinear properties and hysteresis effects of the model parameters with respect to the conventional diaphragmatic navigator. The optimal combination and weighting of the navigators is determined on the basis of a principal component analysis (PCA). Thus, based on a given navigator measurement the current motion state of the object can be predicted by means of the calibrated motion model. The 3D motion model is applied in high‐resolution coronary MR angiography examinations (CMRA) to prospectively correct for respiration‐induced motion. The basic feasibility of the proposed calibration procedure was shown in 16 volunteers. Furthermore, the application of the calibrated motion model for CMRA examinations of the right coronary artery (RCA) was tested in 10 volunteers. The superiority of a calibrated 3D translation model over the conventional 1D translation model with a fixed correction factor and the potential of affine prospective motion correction for CMRA are demonstrated. Magn Reson Med 50:122–131, 2003. © 2003 Wiley‐Liss, Inc.

[1]  M. McConnell,et al.  Prospective adaptive navigator correction for breath‐hold MR coronary angiography , 1997, Magnetic resonance in medicine.

[2]  D. Pennell,et al.  Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[3]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[4]  René M. Botnar,et al.  Coronary magnetic resonance angiography for the detection of coronary stenoses. , 2001, The New England journal of medicine.

[5]  M. McConnell,et al.  Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.

[6]  J Felblinger,et al.  Amplitude demodulation of the electrocardiogram signal (ECG) for respiration monitoring and compensation during MR examinations , 1997, Magnetic resonance in medicine.

[7]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[8]  C H Lorenz,et al.  Novel real‐time R‐wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions , 1999, Magnetic resonance in medicine.

[9]  P. Börnert,et al.  Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results. , 2001, Radiology.

[10]  Jennifer Keegan,et al.  Coronary artery motion with the respiratory cycle during breath‐holding and free‐breathing: Implications for slice‐followed coronary artery imaging , 2002, Magnetic resonance in medicine.

[11]  O. Dössel,et al.  Respiratory motion in coronary magnetic resonance angiography: A comparison of different motion models , 2002, Journal of magnetic resonance imaging : JMRI.

[12]  René M. Botnar,et al.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. , 1999, Radiology.

[13]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[14]  Olaf Dössel,et al.  Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration , 2002, IEEE Transactions on Medical Imaging.

[15]  René M. Botnar,et al.  Superiority of prone position in free‐breathing 3D coronary MRA in patients with coronary disease , 2001, Journal of magnetic resonance imaging : JMRI.

[16]  H. Oswald,et al.  Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography , 1999, Magnetic resonance in medicine.

[17]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[18]  T K Foo,et al.  Vessel tracking: prospective adjustment of section-selective MR angiographic locations for improved coronary artery visualization over the cardiac cycle. , 2000, Radiology.

[19]  J. A. Derbyshire,et al.  Dynamic scan‐plane tracking using MR position monitoring , 1998, Journal of Magnetic Resonance Imaging.

[20]  J Keegan,et al.  MR navigator‐echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography , 1997, Journal of magnetic resonance imaging : JMRI.

[21]  R. Edelman,et al.  Coronary arteries: breath-hold MR angiography. , 1991, Radiology.

[22]  René M. Botnar,et al.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. , 1999, Journal of the American College of Cardiology.

[23]  R. Pettigrew,et al.  Two-dimensional coronary MR angiography without breath holding. , 1996, Radiology.

[24]  R. Ordidge,et al.  Global Call to Action on MR Safety , 1999, Journal of magnetic resonance imaging : JMRI.