Development of computer-based measurements and their application to PD pattern analysis

After referring briefly to the earlier developments of computer-based PD measurements in the 1970s, the paper outlines how the introduction of new technology has resulted in the design and production of a number of digital systems for use in test laboratories and on site. In order to avoid overgeneralization, the basis of the hardware required for detection and recording of the PD pulses is described by reference to a particular system, it being understood that many detailed variations are possible depending on the application. The paper describes a number of parameters that can be calculated by software and used to characterize the PD behavior. These include the IEC-270 integrated quantities, statistical moments and other fingerprints for recognizing the PD patterns within the power frequency cycle. Examples are given of the patterns obtained on equipment and samples. These are necessarily selective and are intended to indicate how the techniques may be applied. It is concluded that these new methods will become valuable in procedures for assessing the condition of electrical insulation, in particular faults or defects, but must be used in conjunction with existing techniques until improved confidence is achieved in interpreting results, especially in respect of the various phase-resolved distributions and calibration procedures. >

[1]  P.H.F. Morshuis Time-resolved discharge measurements , 1993 .

[2]  F. Kreuger,et al.  Industrial high voltage , 1991 .

[3]  R. J. Van Brunt,et al.  Importance of unraveling memory propagation effects in interpreting data on partial discharge statistics , 1993 .

[4]  Ryszard Malewski,et al.  Digital acquisition and processing of partial discharges during acceptance test of HV transformers , 1989 .

[5]  H. Kranz,et al.  Partial discharge diagnosis using statistical optimization on a PC-based system , 1992 .

[6]  B. T. Phung,et al.  Application of digital filtering techniques to the determination of partial discharge location in transformers , 1989 .

[7]  L. Niemeyer,et al.  Generic procedure for classification of aged insulating system , 1991, [1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials.

[8]  M. Hoof,et al.  Pulse-sequence-analysis, a way to get a better insight into the physics of discharges , 1993 .

[9]  D.A. Nattrass,et al.  Partial discharge measurement and interpretation , 1988, IEEE Electrical Insulation Magazine.

[10]  A. T. Starr,et al.  The measurement of discharges in dielectrics , 1936 .

[11]  Magdy M. A. Salama,et al.  Discrimination between PD pulse shapes using different neural network paradigms , 1994 .

[12]  P. von Glahn,et al.  Performance evaluation of a new digital partial discharge recording and analysis system , 1994 .

[13]  K. Horii Development of tuning type partial discharge detector with noise discrimination and computer aided automation system , 1988, Proceedings., Second International Conference on Properties and Applications of Dielectric Materials.

[14]  B. T. Phung,et al.  Application of a computer-based partial discharge measurement system (CDA3) for identifying possible insulation fault conditions , 1994, Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM).

[15]  I.J. Kemp,et al.  The analysis of partial discharge activity by microprocessor-based instrumentation , 1984, 1984 IEEE International Conference on Eletrical Insulation.

[16]  N. Hozumi,et al.  Discrimination of partial discharge patterns using a neural network , 1991 .

[17]  E. Gulski,et al.  Computer-aided measurement of partial discharges in HV equipment , 1993 .

[18]  B. T. Phung,et al.  The use of artificial neural networks in discriminating partial discharge patterns , 1992 .

[19]  F. H. Kreuger,et al.  Partial Discharge Detection in High Voltage Equipment , 1990 .

[20]  F. H. Kreuger,et al.  Automized Recognition of Partial Discharges in Cavities , 1990 .

[21]  E. Gulski,et al.  Neural networks as a tool for recognition of partial discharges , 1993 .

[22]  J.P. Steiner Partial discharge. IV. Commercial PD testing , 1991, IEEE Electrical Insulation Magazine.

[23]  Tr Blackburn,et al.  The Use of Computer-based Partial Discharge Measurements for Plant Condition Monitoring , 1994 .

[24]  R. Bartnikas,et al.  A Simple Pulse-Height Analyzer for Partial-Discharge-Rate Measurements , 1969 .

[25]  Toshikatsu Tanaka,et al.  A minicomputer-based partial discharge measurement system , 1978, 1978 IEEE International Conference on Electrical Insulation.

[26]  E. Gulski,et al.  Digital computer system for measurement of partial discharges in insulation structures , 1989, Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics.

[27]  H. Matsuzaki,et al.  Internal discharge pulse measurement using a microcomputer , 1986, Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986.

[28]  John Austin,et al.  On-Line Digital Computer System for Measurementof Partial Discharges in Insulation Structures , 1976, IEEE Transactions on Electrical Insulation.