A holistic fault impact analysis of the high-performance sequences of operation for HVAC systems: Modelica-based case study in a medium-office building

Abstract ASHRAE Guideline 36: High-performance sequences of operation (SOO) for Heating, Ventilation, and Air-conditioning (HVAC) Systems has been demonstrated to save 17%-30% energy under ideal simulation environments. However, HVAC systems are susceptible to various types of faults in a real building operation. There are no existing studies that pertain to a comprehensive fault impact analysis of the high-performance control sequences suggested by ASHRAE Guideline 36 for HVAC systems. How these sequences handle and adapt to the various types of faults is still largely unknown. In this context, a comprehensive fault impact analysis and robustness assessment of the high-performance control sequences is conducted. A Modelica-based medium office virtual testbed is developed following the air-side and the plant-side SOO. A total of 359 fault scenarios in three different seasonal operating conditions (cooling, shoulder, and heating seasons) are injected into the baseline model. The evaluated key performance indexes (KPIs) include the operational cost, source energy, site energy, control loop quality, thermal comfort, ventilation, and power system metrics. The faults of the most negative impact are identified for different seasonal operating conditions over all the KPIs. The results also show that high-performance control sequences are well adapted for the vast majority (∼90%) of all the fault scenarios over all the KPIs in this study.

[1]  Zhiqiang Zhai,et al.  Full-Scale Laboratory Test on Energy Dependence on Pressure Drops in HVAC Systems , 2017 .

[2]  John Gelegenis,et al.  Analysis of the energy and cost savings caused by using condensing boilers for heating dwellings in Greece , 2013 .

[3]  P. O. Fanger,et al.  Thermal environment — Human requirements , 1986 .

[4]  Jessica Granderson,et al.  Building fault detection data to aid diagnostic algorithm creation and performance testing , 2020, Scientific Data.

[5]  Zheng O'Neill,et al.  An innovative fault impact analysis framework for enhancing building operations , 2019, Energy and Buildings.

[6]  Ted N. Carnes,et al.  Indoor sound criteria according to the American Society of Heating, Refrigerating and Air‐Conditioning Engineers (ASHRAE)—An introduction , 2005 .

[7]  N. R. Sakthivel,et al.  Vibration based fault diagnosis of monoblock centrifugal pump using decision tree , 2010, Expert Syst. Appl..

[8]  Natascha Milesi Ferretti,et al.  Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx. , 2017, ASHRAE transactions.

[9]  James E. Braun,et al.  Empirical modeling of the impacts of faults on water-cooled chiller power consumption for use in building simulation programs , 2016 .

[10]  Ruxu Du,et al.  Model-based Fault Detection and Diagnosis of HVAC systems using Support Vector Machine method , 2007 .

[11]  Zheng O’Neill,et al.  Energy and ventilation performance analysis for CO2-based demand-controlled ventilation in multiple-zone VAV systems with fan-powered terminal units (ASHRAE RP-1819) , 2020 .

[12]  Xiaohui Zhou,et al.  Development of control quality factor for HVAC control loop performance assessment I—Methodology (ASHRAE RP-1587) , 2019, Science and Technology for the Built Environment.

[13]  V. Adetola,et al.  What are the impacts on the HVAC system when it provides frequency regulation? – A comprehensive case study with a Multi-Zone variable air volume (VAV) system , 2021, Energy and Buildings.

[14]  Shokouh Pourarian,et al.  A tool for evaluating fault detection and diagnostic methods for fan coil units , 2017 .

[15]  Liang Zhang,et al.  Metrics and Methods to Assess Building Fault Detection and Diagnosis Tools , 2019 .

[16]  David H. Blum,et al.  Development and Verification of Control Sequences for Single-Zone Variable Air Volume System Based on ASHRAEGuideline 36 , 2020 .

[17]  Steven T. Taylor,et al.  Energy savings and ventilation performance from CO2-based demand controlled ventilation: Simulation results from ASHRAE RP-1747 (ASHRAE RP-1747) , 2019, Science and Technology for the Built Environment.

[18]  Li Zhengwei,et al.  Preventive approach to determine sensor importance and maintenance requirements , 2013 .

[19]  Tianzhen Hong,et al.  Modeling of HVAC operational faults in building performance simulation , 2017 .

[20]  Woohyun Kim,et al.  A review of fault detection and diagnostics methods for building systems , 2018 .

[21]  P. Xu,et al.  Causes of low delta-T syndrome for chilled water systems in buildings , 2021 .

[22]  Yanfei Li,et al.  A critical review of fault modeling of HVAC systems in buildings , 2018, Building Simulation.

[23]  Paul Raftery,et al.  Comparison of mean radiant and air temperatures in mechanically-conditioned commercial buildings from over 200,000 field and laboratory measurements , 2020, Energy and Buildings.

[24]  Seung Ho Hong,et al.  The effects of service delays on a BACnet-based HVAC control system , 2007 .

[25]  Xiaohui Zhou,et al.  Development of control quality factor for HVAC control loop performance assessment—II: Field testing and results (ASHRAE RP-1587) , 2019 .

[26]  S. T. Bushby,et al.  Fault Detection and Diagnostics for AHUs and VAV Boxes , 2005 .

[27]  Draguna Vrabie,et al.  Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings , 2021 .

[28]  Seung Ho Hong,et al.  A Performance Analysis of BACnet® Local Area Networks , 2008 .

[29]  Gregory S. Pavlak,et al.  Performance of advanced control sequences in handling uncertainty in energy use and indoor environmental quality using uncertainty and sensitivity analysis for control components , 2020 .

[30]  Craig P. Wray,et al.  Duct leakage impacts on VAV system performance in California large commercial buildings , 2003 .

[31]  Hwakong Cheng,et al.  Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits through Modernized BAS Hardware and Software , 2020 .

[32]  Andrew K. Persily,et al.  Analysis of U.S. Commercial Building Envelope Air Leakage Database to Support Sustainable Building Design , 2014 .

[33]  Steven T. Bushby,et al.  Retro-commissioning a performing arts center using HVAC-Cx , 2019 .

[34]  Fuxin Niu,et al.  A novel simulation-based framework for sensor error impact analysis in smart building systems: A case study for a demand-controlled ventilation system , 2020 .

[35]  R. Serban,et al.  CVODES: The Sensitivity-Enabled ODE Solver in SUNDIALS , 2005 .

[36]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[37]  James E. Braun,et al.  Representing Small Commercial Building Faults in EnergyPlus, Part I: Model Development , 2019, Buildings.

[38]  James Shia,et al.  Continuous Commissioning of Buildings: HVAC Fault Detection and Diagnosis , 2018 .

[39]  Thierry S. Nouidui,et al.  Modelica Buildings library , 2014 .