Output levelling of wind power generation system by EDLC energy storage

Utilization of renewable energy are coming up from view points of environmental conservation and depletion of fossil fuel. However, the generated power from renewable energies is always fluctuating due to environmental status. Energy storage system is indispensable to compensate these fluctuating components. Energy capacitor system (ECaSS) connected an electric double-layer capacitor (EDLC) with power-electronics devices is useful for the compensation of fluctuating power since one is capable of controlling both active and reactive power simultaneously. This paper proposes the current-source ECaSS (CS-ECS), which consists of EDLC, buck-boost DC-DC converter, and bi-directional inverter. We have presented the control system for the active/reactive power control of CS-ECS, and have shown the effectiveness of CS-ECS through computer simulations for case of wind power generation system.

[1]  Toshiya Nanahara,et al.  Recent Situation of Wind Power in Foreign Countries and Their Impact on Electric Power System , 2000 .

[2]  Shigeyuki Sugimoto,et al.  A study of series‐parallel changeover circuit of a capacitor bank for an energy storage system utilizing electric double‐layer capacitors , 2003 .

[3]  Tomoyuki Matsuzaka,et al.  Study on Stabilization of a Wind Generator Power Fluctuation , 1997 .

[4]  Yukihiko Sato,et al.  A New Control Strategy to Improve AC Input Current Waveform of Parallel Connected Current Type PWM Rectifiers , 1994 .

[5]  Susumu Yamashiro,et al.  A DEVELOPMENT OF PV-ECS SYSTEM USING A NEW ELECTRICAL ENERGY STORAGE SYSTEM ECS (II) , 1999 .

[6]  Michio Okamura A basic study on power storage capacitor systems , 1996 .

[7]  R. Bonert,et al.  Characterization of double-layer capacitors (DLCs) for power electronics applications , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[8]  Shigeyuki Sugimoto,et al.  Energy Storage System utilizing Lare Capacity Electric Double-Layer Capacitors for Peak-Cut of Power Demand , 1998 .

[9]  Shigeaki Ogawa,et al.  Study on Series-Parallel Changeover Circuit of Capacitor Bank for Energy Storage System Utilizing Electric Double-Layer Capacitors , 2002 .

[10]  Shigeyuki Sugimoto,et al.  Energy storage system utilizing large‐capacity electric double‐layer capacitors for peak‐cut of power demand , 2000 .

[11]  Michio Okamura A Basic Study on Power Storage Capacitor Systems , 1995 .

[12]  Yuh Tyng Huang,et al.  Characteristics of current film heads , 1991 .

[13]  Yoshishige Murakami,et al.  Characteristics of a Current Source AC/DC Converter with Energy Recovery Snubber Circuits and its Multi-Parallel Configuration , 1995 .

[14]  Tokuo Ohnishi,et al.  New PWM Method of Current Fed Type Multi-level Inverter , 1998 .

[15]  R. L. Spyker,et al.  Optimization of double layer capacitor arrays , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[16]  Masaaki Shimizu,et al.  Novel Utility-interactive Electrical Energy Storage System by Electrical Double Layer Capacitors and an Error Tracking Mode PWM Converter , 1998 .