Excitation System for Magnetic Resonance Elastography Using Micro MRI

Magnetic resonance elastography (MRE) is a nondestructive method for measuring the hardness and softness of living tissue by means of magnetic resonance imaging (MRI) coupled with mechanical excitation of the subject. The shear modulus of a tissue is related to the velocity of transverse waves propagating through it, and local movements are obtained from MRI phase images. Micro MRI systems are available for high-resolution MRE measurements of soft materials. Longitudinal waves are effective for long-distance wave propagation from small excitation areas in micro MRI systems, and the transverse waves produced by the longitudinal waves can be used for elastography. This study proposes an excitation system comprising a high-power vibration generator and bar-shaped vibration transmitter made from an elastic material. The transmission characteristics of the glass-fiber-reinforced plastic bar-shaped transducer were evaluated by measuring the accelerations at its base and tip. The performance of the excitation system, which focused on the effects of frequency and amplitude, was investigated for measuring storage and loss modulus distributions in agarose gel. This system could transfer longitudinal waves with an amplitude of 0.5 mm and frequency between 50 and 250 Hz, without significant damping. Moreover, the excitation capabilities for gel phantoms were evaluated by MRE using 0.3T micro MRI equipment. A large amplitude of 0.5 mm and high frequency of 250 Hz produced less data scatter than smaller amplitudes and lower frequencies. MRE performance improved upon using strong excitations.

[1]  R. Ehman,et al.  Magnetic Resonance Elastography in Trabecular Bone : Preliminary Results , 2008 .

[2]  A. Manduca,et al.  Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. , 1995, Science.

[3]  Armando Manduca,et al.  Characterization of the dynamic shear properties of hyaline cartilage using high‐frequency dynamic MR elastography , 2008, Magnetic resonance in medicine.

[4]  A. Manduca,et al.  MR elastography of breast cancer: preliminary results. , 2002, AJR. American journal of roentgenology.

[5]  Dieter Klatt,et al.  Wide-range dynamic magnetic resonance elastography. , 2011, Journal of biomechanics.

[6]  Gen Nakamura,et al.  Viscoelastic properties of soft tissues in a living body measured by MR elastography , 2011 .

[7]  M Lamperth,et al.  Magnetic resonance elastography hardware design: A survey , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  R. Ehman,et al.  Magnetic resonance elastography , 1996, Nature Medicine.

[9]  Gen Nakamura,et al.  Inversion analysis for magnetic resonance elastography , 2008 .

[10]  R L Ehman,et al.  Magnetic resonance elastography of the lung: Technical feasibility , 2006, Magnetic resonance in medicine.

[11]  Mark E Ladd,et al.  Actuation Systems for MR Elastography , 2008, IEEE Engineering in Medicine and Biology Magazine.

[12]  R. Ehman,et al.  Magnetic resonance elastography: A review , 2010, Clinical anatomy.

[13]  Richard L Ehman,et al.  Evaluation of healthy and diseased muscle with magnetic resonance elastography. , 2002, Archives of physical medicine and rehabilitation.

[14]  Mickael Tanter,et al.  Viscoelastic shear properties of in vivo breast lesions measured by MR elastography. , 2005, Magnetic resonance imaging.

[15]  R. Ehman,et al.  MR elastography of liver tumors: preliminary results. , 2008, AJR. American journal of roentgenology.

[16]  Clifford R. Jack,et al.  Magnetic resonance elastography of the brain , 2008, NeuroImage.

[17]  J. F. Greenleaf,et al.  Magnetic resonance elastography: Non-invasive mapping of tissue elasticity , 2001, Medical Image Anal..

[18]  E C Clarke,et al.  Using static preload with magnetic resonance elastography to estimate large strain viscoelastic properties of bovine liver. , 2011, Journal of biomechanics.