An advanced phantom study assessing the feasibility of neuronal current imaging by ultra-low-field NMR.

In ultra-low-field (ULF) NMR/MRI, a common scheme is to magnetize the sample by a polarizing field of up to hundreds of mT, after which the NMR signal, precessing in a field on the order of several μT, is detected with superconducting quantum interference devices (SQUIDs). In our ULF-NMR system, we polarize with up to 50mT and deploy a single-stage DC-SQUID current sensor with an integrated input coil which is connected to a wire-wound Nb gradiometer. We developed this system (white noise 0.50fT/√Hz) for assessing the feasibility of imaging neuronal currents by detecting their effect on the ULF-NMR signal. Magnetoencephalography investigations of evoked brain activity showed neuronal dipole moments below 50nAm. With our instrumentation, we have studied two different approaches for neuronal current imaging. In the so-called DC effect, long-lived neuronal activity shifts the Larmor frequency of the surrounding protons. An alternative strategy is to exploit fast neuronal activity as a tipping pulse. This so-called AC effect requires the proton Larmor frequency to match the frequency of the neuronal activity, which ranges from near-DC to ∼kHz. We emulated neuronal activity by means of a single dipolar source in a physical phantom, consisting of a hollow sphere filled with an aqueous solution of CuSO4 and NaCl. In these phantom studies, with physiologically relevant dipole depths, we determined resolution limits for our set-up for the AC and the DC effect of ∼10μAm and ∼50nAm, respectively. Hence, the DC effect appears to be detectable in vivo by current ULF-NMR technology.

[1]  Jari Penttilä,et al.  Hybrid ultra‐low‐field MRI and magnetoencephalography system based on a commercial whole‐head neuromagnetometer , 2013, Magnetic resonance in medicine.

[2]  Jia-Hong Gao,et al.  Direct MRI detection of neuronal magnetic fields in the brain: Theoretical modeling , 2006, NeuroImage.

[3]  M. Lynn,et al.  The application of electromagnetic theory to electrocardiology. I. Derivation of the integral equations. , 1967, Biophysical journal.

[4]  D. Plenz,et al.  Direct magnetic resonance detection of neuronal electrical activity , 2006, Proceedings of the National Academy of Sciences.

[5]  Bruce R. Rosen,et al.  Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging. , 1983, Physics in Medicine and Biology.

[6]  Y. Greenberg,et al.  Application of superconducting quantum interference devices to nuclear magnetic resonance , 1998 .

[7]  Gabriel Curio,et al.  On the feasibility of neurocurrent imaging by low-field nuclear magnetic resonance , 2010 .

[8]  R. Ilmoniemi,et al.  Selective localization of alpha brain activity with neuromagnetic measurements. , 1984, Electroencephalography and clinical neurophysiology.

[9]  J. D. Munck A linear discretization of the volume conductor boundary integral equation using analytically integrated elements (electrophysiology application) , 1992 .

[10]  Bruno Maraviglia,et al.  Challenges for detection of neuronal currents by MRI. , 2006, Magnetic resonance imaging.

[11]  M. Burghoff,et al.  Measures to reduce the residual field and field gradient inside a magnetically shielded room by a factor of more than 10 , 2013 .

[12]  Michelle A. Espy,et al.  Toward direct neural current imaging by resonant mechanisms at ultra-low field , 2008, NeuroImage.

[13]  A. N. Matlashov,et al.  SQUID-based instrumentation for ultralow-field MRI , 2007 .

[14]  L. Trahms,et al.  Are brain currents detectable by means of low-field NMR? A phantom study. , 2011, Magnetic resonance imaging.

[15]  Juha Hassel,et al.  Avoiding eddy-current problems in ultra-low-field MRI with self-shielded polarizing coils. , 2011, Journal of magnetic resonance.

[16]  D. Drung,et al.  Highly Sensitive and Easy-to-Use SQUID Sensors , 2007, IEEE Transactions on Applied Superconductivity.

[17]  R. Ilmoniemi,et al.  Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain , 1993 .

[18]  R. Hren,et al.  Value and limitations of an inverse solution for two equivalent dipoles in localising dual accessory pathways , 2003, Medical and Biological Engineering and Computing.

[19]  L. Trahms,et al.  Simultaneous measurements of somatosensory evoked AC and near-DC MEG signals , 2011, Biomedizinische Technik. Biomedical engineering.

[20]  N. Logothetis,et al.  Neurophysiology of the BOLD fMRI Signal in Awake Monkeys , 2008, Current Biology.

[21]  John Clarke,et al.  SQUID-detected magnetic resonance imaging in microtesla fields. , 2007, Annual review of biomedical engineering.

[22]  Martin Burghoff,et al.  Magnetic resonance imaging at frequencies below 1 kHz. , 2013, Magnetic resonance imaging.

[23]  M Smith,et al.  Near infrared spectroscopy. , 1999, British journal of anaesthesia.

[24]  Elaine Best,et al.  The magnetic field inside special conducting geometries due to internal current , 2004, IEEE Transactions on Biomedical Engineering.

[25]  A. S. Ferguson,et al.  A complete linear discretization for calculating the magnetic field using the boundary element method , 1994, IEEE Transactions on Biomedical Engineering.

[26]  Seong-Min Hwang,et al.  Evaluation of cancellation coil for precision magnetic measurements with strong prepolarization field inside shielded environment , 2012 .

[27]  M A Espy,et al.  Co-Registration of Interleaved MEG and ULF MRI Using a 7 Channel Low-$T_{\rm c}$ SQUID System , 2011, IEEE Transactions on Applied Superconductivity.

[28]  J. Hutchison,et al.  Liquid helium cryostat for SQUID-based MRI receivers , 2005 .

[29]  Martin Burghoff,et al.  Neuronal current detection with low-field magnetic resonance: simulations and methods. , 2009, Magnetic resonance imaging.

[30]  T. Owens,et al.  SQUID-Based Microtesla MRI for In Vivo Relaxometry of the Human Brain , 2009, IEEE Transactions on Applied Superconductivity.

[31]  Robert H Kraus,et al.  Microtesla MRI of the human brain combined with MEG. , 2008, Journal of magnetic resonance.

[32]  B R Rosen,et al.  Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging , 1983, Physics in medicine and biology.