3-D transcranial ultrasound imaging with bilateral phase aberration correction of multiple isoplanatic patches: a pilot human study with microbubble contrast enhancement.

With stroke currently the second-leading cause of death globally, and 87% of all strokes classified as ischemic, the development of a fast, accessible, cost-effective approach for imaging occlusive stroke could have a significant impact on health care outcomes and costs. Although clinical examination and standard computed tomography alone do not provide adequate information for understanding the complex temporal events that occur during an ischemic stroke, ultrasound imaging is well suited to the task of examining blood flow dynamics in real time and may allow for localization of a clot. A prototype bilateral 3-D ultrasound imaging system using two matrix array probes on either side of the head allows for correction of skull-induced aberration throughout two entire phased array imaging volumes. We investigated the feasibility of applying this custom correction technique in five healthy volunteers with Definity microbubble contrast enhancement. Subjects were scanned simultaneously via both temporal acoustic windows in 3-D color flow mode. The number of color flow voxels above a common threshold increased as a result of aberration correction in five of five subjects, with a mean increase of 33.9%. The percentage of large arteries visualized by 3-D color Doppler imaging increased from 46% without aberration correction to 60% with aberration correction.

[1]  M. Hennerici,et al.  Improved Detection of Intracerebral Hemorrhage with Transcranial Ultrasound Perfusion Imaging , 2008, Cerebrovascular Diseases.

[2]  G. Moneta,et al.  Thrombolysis with Alteplase 3 to 4.5 Hours after Acute Ischemic Stroke , 2009 .

[3]  Alessandro Bozzato,et al.  Intracranial collateral pathways assessed by contrast-enhanced three-dimensional transcranial color-coded sonography. , 2004, Ultrasound in medicine & biology.

[4]  Thilo Hölscher,et al.  Prehospital use of portable ultrasound for stroke diagnosis and treatment initiation , 2012 .

[5]  Bogdan Draganski,et al.  Observation on the Integrity of the Blood‐Brain Barrier After Microbubble Destruction by Diagnostic Transcranial Color‐Coded Sonography , 2002, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[6]  G T Clement,et al.  A non-invasive method for focusing ultrasound through the human skull. , 2002, Physics in medicine and biology.

[7]  G. R. Curry,et al.  The acoustic characteristics of the skull. , 1978, Ultrasound in medicine & biology.

[8]  G. Seidel,et al.  Harmonic imaging of the human brain. Visualization of brain perfusion with ultrasound. , 2000, Stroke.

[9]  R. Aaslid,et al.  Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. , 1982, Journal of neurosurgery.

[10]  G. Donnan,et al.  4.5 hours: the new time window for tissue plasminogen activator in stroke. , 2009, Stroke.

[11]  A B Metha,et al.  Multiconjugate adaptive optics applied to an anatomically accurate human eye model. , 2006, Optics express.

[12]  M. Roizen Forecasting the Future of Cardiovascular Disease in the United States: A Policy Statement From the American Heart Association , 2012 .

[13]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Bernard Delabre,et al.  On-sky Testing of the Multi-Conjugate Adaptive Optics Demonstrator , 2007 .

[15]  M. Turhan Taner,et al.  ESTIMATION AND CORRECTION OF NEAR‐SURFACE TIME ANOMALIES , 1974 .

[16]  Edward D. Light,et al.  The ultrasound brain helmet for 3D transcranial Doppler imaging , 2009, 2009 IEEE International Ultrasonics Symposium.

[17]  J. Barger,et al.  Acoustical properties of the human skull. , 1978, The Journal of the Acoustical Society of America.

[18]  Gregg E. Trahey,et al.  Wavefront estimation in the human breast , 2001, SPIE Medical Imaging.

[19]  S. W. Smith,et al.  Pitch-catch phase aberration correction of multiple isoplanatic patches for 3-D transcranial ultrasound imaging , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  G E Trahey,et al.  Phased array ultrasound imaging through planar tissue layers. , 1986, Ultrasound in medicine & biology.

[21]  B. D. Steinberg Radar imaging from a distorted array , 1981 .

[22]  Walter J Koroshetz,et al.  Arterial occlusion revealed by CT angiography predicts NIH stroke score and acute outcomes after IV tPA treatment. , 2005, AJNR. American journal of neuroradiology.

[23]  R. Kern,et al.  Diagnosis of Intracerebral Hemorrhage with Transcranial Ultrasound , 2009, Cerebrovascular Diseases.

[24]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Daren Dillon,et al.  Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons , 2010, Optics express.

[26]  M. Grocott,et al.  Stroke at high altitude diagnosed in the field using portable ultrasound. , 2011, Wilderness & environmental medicine.

[27]  D. Mozaffarian,et al.  Heart disease and stroke statistics--2012 update: a report from the American Heart Association. , 2012, Circulation.

[28]  M Marinoni,et al.  Technical limits in transcranial Doppler recording: inadequate acoustic windows. , 1997, Ultrasound in medicine & biology.

[29]  Alexis Kudryashov,et al.  Human retina imaging: widening of high resolution area , 2008 .

[30]  J L Thomas,et al.  Optimal focusing by spatio-temporal inverse filter. II. Experiments. Application to focusing through absorbing and reverberating media. , 2001, The Journal of the Acoustical Society of America.

[31]  Mickael Tanter,et al.  Effects of nonlinear ultrasound propagation on high intensity brain therapy. , 2011, Medical physics.

[32]  K. Hynynen,et al.  Transcranial ultrasound focus reconstruction with phase and amplitude correction , 2004, IEEE Ultrasonics Symposium, 2004.

[33]  H. Etani,et al.  [Assessment of the rate of successful transcranial Doppler recording through the temporal windows in Japanese with special reference to aging and sex]. , 1992, Nihon Ronen Igakkai zasshi. Japanese journal of geriatrics.

[34]  Jacques M. Beckers,et al.  Increasing the size of the isoplanatic patch with multiconjugate adaptive optics. , 1988 .

[35]  S.W. Smith,et al.  Comparison of 3-D multi-lag cross- correlation and speckle brightness aberration correction algorithms on static and moving targets , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  Transcranial sonography in prehospital setting. , 2011, The American journal of emergency medicine.

[37]  J. Bogousslavsky,et al.  The Lausanne Stroke Registry: analysis of 1,000 consecutive patients with first stroke. , 1988, Stroke.

[38]  Tibo Gerriets,et al.  Consensus Recommendations for Transcranial Color-Coded Duplex Sonography for the Assessment of Intracranial Arteries in Clinical Trials on Acute Stroke , 2009, Stroke.

[39]  B. D. Lindsey,et al.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[40]  M. Kaste,et al.  Intravenous thrombolysis with recombinant tissue plasminogen activator for acute hemispheric stroke. The European Cooperative Acute Stroke Study (ECASS) , 1995, JAMA.

[41]  Oliver D Kripfgans,et al.  Towards aberration correction of transcranial ultrasound using acoustic droplet vaporization. , 2008, Ultrasound in medicine & biology.

[42]  Gregory T. Clement,et al.  Longitudinal and shear mode ultrasound propagation in human skull bone. , 2006, Ultrasound in medicine & biology.

[43]  H. Przuntek,et al.  Insufficient and absent acoustic temporal bone window: potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography. , 1997, Ultrasound in medicine & biology.

[44]  B. Savord,et al.  Fully sampled matrix transducer for real time 3D ultrasonic imaging , 2003, IEEE Symposium on Ultrasonics, 2003.

[45]  J L Thomas,et al.  Optimal focusing by spatio-temporal inverse filter. I. Basic principles. , 2001, The Journal of the Acoustical Society of America.

[46]  R. Waag,et al.  Reduction of variance in spectral estimates for correction of ultrasonic aberration , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[47]  Jeremy J Dahl,et al.  Direction of Arrival Filters for Improved Aberration Estimation , 2008, Ultrasonic imaging.

[48]  A. Alexandrov,et al.  CLOTBUST: Design of a Randomized Trial of Ultrasound‐Enhanced Thrombolysis for Acute Ischemic Stroke , 2004, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[49]  J Munch,et al.  Compact, holographic correction of aberrated telescopes. , 1997, Applied optics.

[50]  R. Rosenfeld Patients , 2012, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[51]  M Fink,et al.  Adaptive focusing for transcranial ultrasound imaging using dual arrays. , 2006, The Journal of the Acoustical Society of America.

[52]  Brooks D. Lindsey,et al.  Simultaneous bilateral real-time 3-d transcranial ultrasound imaging at 1 MHz through poor acoustic windows. , 2013, Ultrasound in medicine & biology.

[53]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[54]  Thilo Hölscher,et al.  Transcranial Ultrasound from Diagnosis to Early Stroke Treatment – Part 2: Prehospital Neurosonography in Patients with Acute Stroke – The Regensburg Stroke Mobile Project , 2012, Cerebrovascular Diseases.

[55]  S.W. Smith,et al.  Phase-aberration correction with a 3-D ultrasound scanner: feasibility study , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[56]  S. Kasner,et al.  Suitability of Temporal Bone Acoustic Window: Conventional TCD Versus Transcranial Color‐Coded Duplex Sonography , 2007, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[57]  C. Nimsky,et al.  Contrast-Enhanced Ultrasound Ventriculography , 2012, Neurosurgery.

[58]  Ulrich G. Hofmann,et al.  Detecting Stripe Artifacts in Ultrasound Images , 2009, Journal of Digital Imaging.

[59]  Bogdan Draganski,et al.  Transcranial Ultrasound Brain Perfusion Assessment With a Contrast Agent-Specific Imaging Mode: Results of a Two-Center Trial , 2005, Stroke.

[60]  Kullervo Hynynen,et al.  Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls , 2011, Physics in medicine and biology.

[61]  G. Trahey,et al.  Spatial and temporal aberrator stability for real-time adaptive imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[62]  Thilo Hölscher,et al.  Transcranial Ultrasound from Diagnosis to Early Stroke Treatment , 2008, Cerebrovascular Diseases.

[63]  Rachel B. Liu Ultrasound applications in EMS , 2015 .

[64]  H. Reichmann,et al.  Contrast-enhanced transcranial color-coded duplexsonography in stroke patients with limited bone windows. , 2000, AJNR. American journal of neuroradiology.

[65]  J.C. Tillett,et al.  A model of distributed phase aberration for deblurring phase estimated from scattering , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[66]  M Kaps,et al.  Potential and limitations of transcranial color-coded sonography in stroke patients. , 1995, Stroke.

[67]  R C Waag,et al.  Time-shift compensation of ultrasonic pulse focus degradation using least-mean-square error estimates of arrival time. , 1992, The Journal of the Acoustical Society of America.

[68]  Stephen W. Smith,et al.  Real-time 3-D contrast-enhanced transcranial ultrasound and aberration correction. , 2008, Ultrasound in medicine & biology.

[69]  Stephen W. Smith,et al.  The ultrasound brain helmet: early human feasibility study of multiple simultaneous 3D scans of cerebral vasculature , 2009, Medical Imaging.

[70]  Byron M. Welsh,et al.  Analysis of Multiconjugate Adaptive Optics , 1992, Adaptive Optics for Large Telescopes.

[71]  X. Yin,et al.  The Stripe Artifact in Transcranial Ultrasound Imaging , 2010, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[72]  S. Vogl,et al.  Prehospital ultrasound in emergency medicine: incidence, feasibility, indications and diagnoses , 2010, European journal of emergency medicine : official journal of the European Society for Emergency Medicine.

[73]  Sandy Cochran,et al.  Future integration of silicon electronics with miniature piezoelectric ultrasonic transducers and arrays , 2010, 2010 IEEE International Ultrasonics Symposium.

[74]  Mathias Fink,et al.  Optimal focusing through aberrating media: a comparison between time reversal mirror and time delay correction techniques , 1991, IEEE 1991 Ultrasonics Symposium,.

[75]  B. Książkiewicz,et al.  Imaging of spontaneous intracerebral hemorrhages by means of transcranial color-coded sonography. , 2012, European journal of radiology.

[76]  Gregory T. Clement,et al.  Enhanced ultrasound transmission through the human skull using shear mode conversion. , 2004, The Journal of the Acoustical Society of America.

[77]  R. Muller,et al.  Real-time correction of atmospherically degraded telescope images through image sharpening , 1974 .

[78]  W. Shi,et al.  Determination of temporal bone Isoplanatic Patch sizes for transcranial phase aberration correction , 2008, 2008 IEEE Ultrasonics Symposium.

[79]  M. Hennerici,et al.  Real-Time Ultrasound Brain Perfusion Imaging with Analysis of Microbubble Replenishment in Acute MCA Stroke , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.