The quadruple approach in the title refers to four different studies over a period of 3 years. The common factor in these studies is the methodology of the (Brussels) Electromyographic Signal Processing and Analysis System (ESPAS), a hardware and software EMG data acquisition system that has constantly been improved. Therefore, the ESPAS methodology is described extensively (i.e. the electrodes, amplifier, tape-recorder and processing hardware). Experiment 1 investigated muscular behaviour in target shooting, both indoors (18 and 25 m) and outdoors (50, 70 and 90 m). It was found (via iEMG) that a significant increase in activity only exists between 25 and 50 m, and that there is no linear increase of activity with increased distance. No differences in muscular pattern (IDANCO system: Clarys and Cabri, 1988) or activity between the indoor distances and between the outdoor distances were found. Experiment 2 investigated the muscular economy of four string grips: the three-finger grip, two-finger grip, thumb grip and reversed grip. The largest variations in activity were found for the two most unfamiliar grips, i.e. the thumb and reversed grips; however, low iEMG and the rapid precision improvement (over a limited number of shots) suggest that the thumb grip, if practised long enough, might be the most economical technique. Experiment 3 attempted to differentiate muscular activity and a number of performance variables in three different populations of archers--Olympic athletes, National competitors and beginners--in order to obtain feedback regarding improved performance. Apparently, overall muscle pattern, intensities and arrow speed were not discriminatory. The differences found between the groups (or levels of skill) were affected by the ability to reproduce identical patterns and arrow velocities in consecutive shots and by the constancy of neuromuscular control of the M. trapezius, M. biceps brachii and M. extensor digitorum. Finally, Experiment 4 investigated the muscular activity of elite archers shooting at distances of 70 and 90 m with and without stabilizers. Differences in iEMG were not supported by differences in precision. Over time, the low iEMG in shooting without stabilizers increases precision and delays fatigue.
[1]
J. P. Clarys,et al.
EMG of repetitive and rhythmic (sports) movements
,
1988,
Proceedings of a Special Symposium on Maturing Technologies and Emerging Horizons in Biomedical Engineering..
[2]
J P Clarys,et al.
Electromyography applied to sport ergonomics.
,
1988,
Ergonomics.
[3]
C. Long,et al.
Intrinsic-extrinsic muscle control of the hand in power grip and precision handling. An electromyographic study.
,
1970,
The Journal of bone and joint surgery. American volume.
[4]
R. King.
An Archer’s Notes
,
1989
.
[5]
J P Clarys,et al.
The muscle activity paradox during circular rhythmic leg movements.
,
1988,
Journal of sports sciences.
[6]
J P Clarys,et al.
Influence of ski materials on muscle activity.
,
1986,
Journal of sports sciences.
[7]
David F. Butler.
The new archery
,
1973
.
[8]
Keith C. Schuyler.
Archery, from golds to big game
,
1970
.
[9]
Paul Hougham.
The encyclopedia of archery
,
1958
.