Portable Gait Lab: Estimating Over-Ground 3D Ground Reaction Forces Using Only a Pelvis IMU

As an alternative to force plates, an inertial measurement unit (IMU) at the pelvis can offer an ambulatory method for measuring total center of mass (CoM) accelerations and, thereby, the ground reaction forces (GRF) during gait. The challenge here is to estimate the 3D components of the GRF. We employ a calibration procedure and an error state extended Kalman filter based on an earlier work to estimate the instantaneous 3D GRF for different over-ground walking patterns. The GRF were then expressed in a body-centric reference frame, to enable an ambulatory setup not related to a fixed global frame. The results were validated with ForceShoesTM, and the average error in estimating instantaneous shear GRF was 5.2 ± 0.5% of body weight across different variable over-ground walking tasks. The study shows that a single pelvis IMU can measure 3D GRF in a minimal and ambulatory manner during over-ground gait.

[1]  Edwin van Asseldonk,et al.  Ambulatory Estimation of Center of Mass Displacement During Walking , 2009, IEEE Transactions on Biomedical Engineering.

[2]  Jurandir Nadal,et al.  Residual analysis of ground reaction forces simulation during gait using neural networks with different configurations , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Edwin van Asseldonk,et al.  Use of Inertial Sensors for Ambulatory Assessment of Center-of-Mass Displacements During Walking , 2012, IEEE Transactions on Biomedical Engineering.

[4]  John Barton,et al.  Predicting Three-Dimensional Ground Reaction Forces in Running by Using Artificial Neural Networks and Lower Body Kinematics , 2019, IEEE Access.

[5]  John R. Rebula,et al.  Measurement of foot placement and its variability with inertial sensors. , 2013, Gait & posture.

[6]  E. Mohammadi,et al.  Barriers and facilitators related to the implementation of a physiological track and trigger system: A systematic review of the qualitative evidence , 2017, International journal for quality in health care : journal of the International Society for Quality in Health Care.

[7]  Rafael C González,et al.  Real-time gait event detection for normal subjects from lower trunk accelerations. , 2010, Gait & posture.

[8]  Jaap H van Dieën,et al.  Control of human gait stability through foot placement , 2018, Journal of The Royal Society Interface.

[9]  Frank J. Wouda,et al.  Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors , 2018, Front. Physiol..

[10]  Jay L. Devore,et al.  INTRODUCTION TO SIGNAL PROCESSING , 2005 .

[11]  Andrea Ancillao,et al.  Indirect Measurement of Ground Reaction Forces and Moments by Means of Wearable Inertial Sensors: A Systematic Review , 2018, Sensors.

[12]  Suzanne Lesecq,et al.  Calibration methods for inertial and magnetic sensors , 2009 .

[13]  Sungjae Hwang,et al.  Novel algorithm for the hemiplegic gait evaluation using a single 3-axis accelerometer , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Jaap H. Buurke,et al.  Portable Gait Lab: Tracking Relative Distances of Feet and CoM Using Three IMUs , 2020, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  Angelo M. Sabatini,et al.  Assessment of walking features from foot inertial sensing , 2005, IEEE Transactions on Biomedical Engineering.

[16]  Maria Cristina Bisi,et al.  Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements. , 2018, Gait & posture.

[17]  Conor J. Walsh,et al.  Indirect measurement of anterior-posterior ground reaction forces using a minimal set of wearable inertial sensors: from healthy to hemiparetic walking , 2020, Journal of NeuroEngineering and Rehabilitation.

[18]  A L Hof,et al.  The condition for dynamic stability. , 2005, Journal of biomechanics.

[19]  Carlo Menon,et al.  Estimating Vertical Ground Reaction Force during Walking Using a Single Inertial Sensor , 2020, Sensors.

[20]  P. Veltink,et al.  Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces. , 2007, Gait & posture.

[21]  F C T van der Helm,et al.  Use of pressure insoles to calculate the complete ground reaction forces. , 2004, Journal of biomechanics.

[22]  Mohamed Irfan Mohamed Refai,et al.  Portable Gait Lab: Estimating 3D GRF Using a Pelvis IMU in a Foot IMU Defined Frame , 2020, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[23]  Jaap H. Buurke,et al.  Gait and Dynamic Balance Sensing Using Wearable Foot Sensors , 2019, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  D. Howard,et al.  Whole body inverse dynamics over a complete gait cycle based only on measured kinematics. , 2008, Journal of biomechanics.

[25]  P. Veltink,et al.  Ambulatory Estimation of Relative Foot Positions by Fusing Ultrasound and Inertial Sensor Data , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  Mark de Zee,et al.  Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture , 2016, Sensors.

[27]  Guang-Zhong Yang,et al.  Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review , 2016, IEEE Journal of Biomedical and Health Informatics.

[28]  Tao Liu,et al.  How Magnetic Disturbance Influences the Attitude and Heading in Magnetic and Inertial Sensor-Based Orientation Estimation , 2017, Sensors.

[29]  H Martin Schepers,et al.  Analysis of Balance during Functional Walking in Stroke Survivors , 2016, PloS one.