Multigate transcranial doppler ultrasound system with real-time embolic signal identification and archival

An integrated system for acquisition and processing of intracranial and extracranial Doppler signals and automatic embolic signal detection has been developed. The hardware basis of the system is a purpose-built acquisition/processing board that includes a multigate Doppler unit controlled through a computer. The signal-processing engine of the system contains a fast Fourier transform (FFT)-based, spectral-analysis unit and an embolic signal-detection unit using expert system reasoning theory. The system is designed so that up to four receive gates from a single transducer can be used to provide useful reasoning information to the embolic signal-detection unit. Alternatively, two transducers can be used simultaneously, either for bilateral transcranial Doppler (TCD) investigations or for simultaneous intraand extracranial investigation of different arteries. The structure of the software will allow the future implementation of embolus detection algorithms that use the information from all four channels when a single transducer is used, or of independent embolus detection in two sets of two channels when two transducers are used. The user-friendly system has been tested in-vitro, and it has demonstrated a 93.6% sensitivity for micro-embolic signal (MES) identification. Preliminary in-vivo results also are encouraging

[1]  E B Ringelstein,et al.  Automatic embolus detection by a neural network. , 1999, Stroke.

[2]  H. Markus,et al.  Multigated Doppler ultrasound in the detection of emboli in a flow model and embolic signals in patients. , 1996, Stroke.

[3]  P R Bell,et al.  Differentiation between emboli and artefacts using dual-gated transcranial Doppler ultrasound. , 1996, Ultrasound in medicine & biology.

[4]  Jürgen Klingelhöfer,et al.  New trends in cerebral hemodynamics and neurosonology , 1997 .

[5]  G Rose,et al.  Real-time identification of cerebral microemboli with US feature detection by a neural network. , 1994, Radiology.

[6]  R G Ackerstaff,et al.  A new algorithm for off-line automated emboli detection based on the pseudo-wigner power distribution and the dual gate TCD technique. , 2000, Ultrasound in medicine & biology.

[7]  A. Lindner,et al.  Differentiation between true microembolic signals and artefacts using an arbitrary sample volume. , 2000, Ultrasound in medicine & biology.

[8]  E B Ringelstein,et al.  Automatic Classification of HITS Into Artifacts or Solid or Gaseous Emboli by a Wavelet Representation Combined With Dual-Gate TCD , 2001, Stroke.

[9]  D. Evans,et al.  Automated embolus identification using a rule-based expert system. , 2001, Ultrasound in medicine & biology.

[10]  P. Tortoli,et al.  Real-time identification and archiving of micro-embolic Doppler signals using a knowledge-based DSP system , 2004, Medical and Biological Engineering and Computing.

[11]  S Cencetti,et al.  Automated identification of Doppler microembolic signals: Comparison of two techniques , 2000, Neurological research.

[12]  K V Ramnarine,et al.  Construction and geometric stability of physiological flow rate wall-less stenosis phantoms. , 2001, Ultrasound in medicine & biology.

[13]  M. Brown,et al.  Computerized Detection of Cerebral Emboli and Discrimination From Artifact Using Doppler Ultrasound , 1993, Stroke.

[14]  Duncan Gillies,et al.  Online automated detection of cerebral embolic signals using a wavelet-based system. , 2004, Ultrasound in medicine & biology.

[15]  D. H. Evans,et al.  Ultrasonic detection of cerebral emboli , 2003, IEEE Symposium on Ultrasonics, 2003.

[16]  L. Cohen,et al.  Time-frequency distributions-a review , 1989, Proc. IEEE.

[17]  Hugh S Markus,et al.  Online automated detection of cerebral embolic signals from a variety of embolic sources. , 2002, Ultrasound in medicine & biology.

[18]  R. Brucher,et al.  Automatic Online Embolus Detection and Artifact Rejection With the First Multifrequency Transcranial Doppler , 2002, Stroke.

[19]  J L Saumet,et al.  Spectrogram analysis of arterial Doppler signals for off-line automated hits detection. , 1999, Ultrasound in medicine & biology.

[20]  E B Ringelstein,et al.  A novel technique for identification of doppler microembolic signals based on the coincidence method: in vitro and in vivo evaluation. , 1996, Stroke.

[21]  A. Lindner,et al.  Automated intraoperative detection of Doppler microembolic signals using the bigate approach. , 1998, Stroke.

[22]  D. Droste,et al.  Microembolus detection by transcranial doppler sonography. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[23]  E B Ringelstein,et al.  Detection of microembolic signals in patients with middle cerebral artery stenosis by means of a bigate probe. A pilot study. , 1996, Stroke.

[24]  Vice President,et al.  An Introduction to Expert Systems , 1989 .