Fast quantitative mapping of absolute water content with full brain coverage

Quantitative mapping of water content, especially in the human brain, has the potential to provide important information for the study and diagnosis of diseases associated with a focal or global change in tissue water homeostasis. In the current work, an imaging method for the precise and accurate quantification of tissue water content is presented. The method allows the acquisition of water content maps with voxel dimensions of 1x1x2 mm(3) and full brain coverage in less than 10 min on a standard clinical 1.5 T scanner. The precision was optimised for human brain imaging and possible sources of systematic error were carefully investigated, demonstrating the ability of the method to quantify water content with high accuracy and precision. The approach was validated in phantom experiments and quantitative cerebral water content maps of a group of 10 healthy volunteers were obtained.

[1]  P. Bendel,et al.  An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing , 1988, Magnetic resonance in medicine.

[2]  J RousseeuwPeter,et al.  A fast algorithm for the minimum covariance determinant estimator , 1999 .

[3]  Heiko Neeb,et al.  Fully Automated Detection of Quantitative Water Content Changes: Application to the Study of Age-and Gender Related Cerebral H2O Patterns , 2005 .

[4]  P. Lundberg,et al.  Novel method for rapid, simultaneous T1, T*2, and proton density quantification , 2007, Magnetic resonance in medicine.

[5]  T. Peters,et al.  High‐resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2 , 2005, Magnetic resonance in medicine.

[6]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .

[7]  M Zaitsev,et al.  Error reduction and parameter optimization of the TAPIR method for fast T1 mapping , 2003, Magnetic resonance in medicine.

[8]  Maolin Qiu,et al.  T1 measurements incorporating flip angle calibration and correction in vivo. , 2006, Journal of magnetic resonance.

[9]  Nadim Joni Shah,et al.  Fully-automated detection of cerebral water content changes: Study of age- and gender-related H2O patterns with quantitative MRI , 2006, NeuroImage.

[10]  W. Wick,et al.  Brain Edema in Neurooncology: Radiological Assessment and Management , 2004, Oncology Research and Treatment.

[11]  Ralf Deichmann,et al.  Fast high‐resolution T1 mapping of the human brain , 2005, Magnetic resonance in medicine.

[12]  Guido Gerig,et al.  A brain tumor segmentation framework based on outlier detection , 2004, Medical Image Anal..

[13]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[14]  S Romanzetti,et al.  A comparison of three SPRITE techniques for the quantitative 3D imaging of the 23Na spin density on a 4T whole-body machine. , 2006, Journal of magnetic resonance.

[15]  A. Mackay,et al.  In vivo measurement of T2 distributions and water contents in normal human brain , 1997, Magnetic resonance in medicine.

[16]  D. Häussinger,et al.  Hepatic encephalopathy and nitrogen metabolism , 2006 .

[17]  P A Rinck,et al.  Nuclear relaxation of human brain gray and white matter: Analysis of field dependence and implications for MRI , 1990, Magnetic resonance in medicine.

[18]  Jürgen Hennig,et al.  Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part II: Echoes in imaging sequences , 1991 .

[19]  B D Ross,et al.  Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water , 1993 .

[20]  B. Rutt,et al.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state , 2003, Magnetic resonance in medicine.

[21]  G. Weiss,et al.  Optimal time spacings for T2 measurements: monoexponential and biexponential systems , 1998, NMR in biomedicine.

[22]  Jonathan A. Jones,et al.  Optimal Sampling Strategies for the Measurement of Spin–Spin Relaxation Times , 1996 .

[23]  P. Tofts Quantitative MRI of the Brain , 2003 .

[24]  M. Zaitsev,et al.  Fast T1 mapping with volume coverage , 2001, Magnetic resonance in medicine.

[25]  Mark Bydder,et al.  Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging , 2003, Journal of computer assisted tomography.

[26]  N. J. Shah,et al.  A New Method for Fast Multislice T 1 Mapping , 2001, NeuroImage.

[27]  W T Sobol,et al.  On the stationary states in gradient echo imaging , 1996, Journal of magnetic resonance imaging : JMRI.

[28]  Nadim Joni Shah,et al.  A new method for fast quantitative mapping of absolute water content in vivo , 2006, NeuroImage.

[29]  C. Laule,et al.  Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology , 2006, Multiple sclerosis.

[30]  N J Shah,et al.  Enhancing the precision of quantitative water content mapping by optimizing sequence parameters , 2006, Magnetic resonance in medicine.

[31]  Katrien van Driessen,et al.  A Fast Algorithm for the Minimum Covariance Determinant Estimator , 1999, Technometrics.