Stable isotope analysis using tunable diode laser spectroscopy.

Measurements of ratios of stable isotopes are used in such diverse fields as petroleum prospecting, medical diagnostics, and planetary exploration. The narrow emission linewidth available from tunable diode lasers permits high-resolution infrared absorption measurements of closely spaced isotopic rovibrational lines. Our dual beam spectrometer uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances. The experimental results reported here indicate that isotopic ratios of carbon in carbon dioxide can be measured to an accuracy of better than 0.4%. This laser spectroscopic technique offers an alternative to the mass spectrometric technique for in situ isotopic analysis in field studies, as well as flight and space applications.

[1]  A. Nier A Mass Spectrometer for Isotope and Gas Analysis , 1947 .

[2]  W. Saunders,et al.  Reaction Rates of Isotopic Molecules , 1987 .

[3]  D. Jennings Absolute line strengths in nu(4), (12)CH(4): a dual-beam diode laser spectrometer with sweep integration. , 1980, Applied optics.

[4]  C. Freed,et al.  Fundamental linewidth in solitary, ultranarrow output PbS1−xSex diode lasers , 1983 .

[5]  A. Mooradian,et al.  Spectral characteristics of external-cavity controlled semiconductor lasers , 1980 .

[6]  M. Lax,et al.  Classical Noise. VI. Noise in Self-Sustained Oscillators near Threshold , 1967 .

[7]  Peter S. Lee,et al.  High resolution infrared diode laser spectroscopy for isotope analysis—Measurement of isotopic carbon monoxide , 1986 .

[8]  G. Björk,et al.  A tool to calculate the linewidth of complicated semiconductor lasers , 1987 .

[9]  A Goldman,et al.  The HITRAN database: 1986 edition. , 1987, Applied optics.

[10]  A. K. Hui,et al.  Rapid computation of the Voigt and complex error functions , 1978 .

[11]  H. Ishikawa,et al.  Spectral characteristics of a three-section wavelength-tunable DBR laser , 1989 .

[12]  David J. Des Marais,et al.  Carbon and its isotopes in mid-oceanic basaltic glasses , 1984 .

[13]  M. Lax Classical Noise. V. Noise in Self-Sustained Oscillators , 1967 .

[14]  C. Henry Theory of the linewidth of semiconductor lasers , 1982 .

[15]  J. Hillman,et al.  Diode laser-CO(2) laser heterodyne spectrometer: measurement of 2sQ(1,1) in 2nu(2) - nu(2) of NH(3). , 1979, Applied optics.

[16]  R. Landshoff,et al.  Quantitative Molecular Spectroscopy and Gas Emissivities , 1959 .

[17]  J. Arnaud Contribution of shot noise to laser diode linewidth , 1988 .

[18]  R. Eng,et al.  Utilization of tunable infrared diode lasers for the determination of labelled molecules in gas mixtures , 1980 .

[19]  A. Schawlow,et al.  Infrared and optical masers , 1958 .

[20]  S. Strahan,et al.  Nitrous oxide as a dynamic tracer in the 1987 airborne Antarctic ozone experiment , 1988, Annual Meeting Optical Society of America.

[21]  C. Henry Theory of the phase noise and power spectrum of a single mode injection laser , 1983 .

[22]  John M. Hayes,et al.  Isotope-ratio-monitoring gas chromatography-mass spectrometry , 1978 .

[23]  D. Labrie,et al.  Radiocarbon dating by infrared laser spectroscopy , 1981 .

[24]  M. O'Leary Carbon isotope fractionation in plants , 1981 .

[25]  A. Hall Applied Optics. , 2022, Science.

[26]  A. Hemmerich,et al.  Optically stabilized narrow linewidth semiconductor laser for high resolution spectroscopy , 1990 .

[27]  D. Welte,et al.  Petroleum Formation and Occurrence , 1989 .

[28]  D. Welford,et al.  Output power and temperature dependence of the linewidth of single‐ frequency cw (GaAl)As diode lasers , 1982 .