In vivo rapid magnetic field measurement and shimming using single scan differential phase mapping

In vivo shimming is a powerful tool for alleviating subjectdependent magnetic field distortions in MRI, although the usually lengthy procedure has limited its use. A magnetic field measurement method called single scan differential phase mapping that can reduce the measurement time of conventional methods by more than half when used with multiple gradient‐recalled echo imaging was developed. An automatic high‐order shimming using the present method was implemented in a commercial MRI system. In vivo field inhomogeneity features and the shimming performances were investigated. The method was found to be useful for improving the quality of echo‐planar images.

[1]  G H Glover,et al.  Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.

[2]  G M Bydder,et al.  Clinical magnetic susceptibility mapping of the brain. , 1987, Journal of computer assisted tomography.

[3]  Hitoshi Yamagata,et al.  Automated shimming of B0 for spectroscopic imaging , 1989 .

[4]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[5]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[6]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[7]  Ching-Ming Lai Reconstructing NMR images under magnetic fields with large inhomogeneities , 1982 .

[8]  K Sekihara,et al.  A new method of measuring static field distribution using modified Fourier NMR imaging , 1985 .

[9]  D W Kormos,et al.  Separation of true fat and water images by correcting magnetic field inhomogeneity in situ. , 1986, Radiology.

[10]  K. Sekihara,et al.  Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging. , 1984, Physics in medicine and biology.

[11]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[12]  D Matthaei,et al.  1H NMR chemical shift selective (CHESS) imaging. , 1985, Physics in medicine and biology.

[13]  S. Posse,et al.  Susceptibility artifacts in spin-echo and gradient-echo imaging , 1990 .

[14]  Peter Mansfield,et al.  BIOLOGICAL AND MEDICAL IMAGING BY NMR , 1978 .

[15]  Andrew A. Maudsley,et al.  Magnetic field measurement by NMR imaging , 1984 .

[16]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[17]  Gary H. Glover,et al.  MR susceptibility misregistration correction , 1993, IEEE Trans. Medical Imaging.

[18]  Eddy-current-compensated field-inhomogeneity mapping in NMR imaging , 1988 .