Light yield nonproportionality of CsI(Tl), CsI(Na), and YAP

CsI(Tl), CsI(Na), and YAP light yield nonproportionality has been characterized using the Compton Coincidence Technique. Measured electron responses were used to calculate photon responses of the scintillators studied. These calculated photon responses were then compared with measured photon responses. In addition results from electron response measurements and photon response calculations were compared with previously reported results. While the CsI(Na) electron response was observed to have the largest deviation from proportionality (about 40%), YAP was observed to have a nearly proportional response. The CsI(Tl) calculated photon response was observed to agree to within 1% with measured photon response in this study for all measured photon energies. While the CsI(Na) calculated photon response agreed to within 1% of measured data for photon energies above 60 keV, deviations up to 4% were observed below 60 keV.

[1]  G. H. Narayan,et al.  Electron responses and intrinsic line-widths in NaI(Tl) , 1969 .

[2]  Richard B. Firestone,et al.  Table of Isotopes , 1978 .

[3]  J. Valentine,et al.  Design of a Compton spectrometer experiment for studying scintillator non-linearity and intrinsic energy resolution , 1994 .

[4]  Calculating nonproportionality of scintillator photon response using measured electron response data , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[5]  P. Dorenbos,et al.  Non-proportionality in the scintillation response and the energy resolution obtainable with scintill , 1995 .

[6]  J. D. Valentine,et al.  The measured electron response nonproportionalities of CaF/sub 2/, BGO, and LSO , 1997 .

[7]  Roberto Pani,et al.  Scintillation properties of YAP:Ce , 1995 .

[8]  B. L. Beron,et al.  The Fluorescent Response of NaI(Tl), CsI(Tl), CsI(Na) and CaF2(Eu) to X-Rays and Low Energy Gamma Rays , 1967 .

[9]  G. T. Seaborg,et al.  Table of the Isotopes , 1948 .

[10]  G. Knoll Radiation detection and measurement , 1979 .

[11]  J. D. Valentine,et al.  Benchmarking the Compton coincidence technique for measuring electron response non-proportionality in inorganic scintillators , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[12]  D. Wolski,et al.  Properties of the YAP : Ce scintillator , 1998 .

[13]  R. B. Murray,et al.  Intrinsic line broadening in NaI(Tl) gamma-ray spectrometers , 1961 .

[14]  J. D. Valentine,et al.  Scintillator light yield nonproportionality: calculating photon response using measured electron response , 1997 .

[15]  R. B. Murray,et al.  Scintillation Process in CsI(Tl). I. Comparison with Activator Saturation Model , 1963 .