In addition to the labor, energy and water consumption are the two main cost drivers in current greenhouse systems. Consequently, considerable effort is expended to conserve energy and water, and look for alternative energy sources, especially environmentally friendly renewable energy sources and technologies. Greenhouses in hot and arid regions also require large quantities of water for irrigation. Using proper technologies and environmental management systems can significantly change the energy and moisture dynamics of greenhouse production systems. This study aims to focus on reducing natural gas, electricity, and water consumption in semi-arid California greenhouses introducing renewable energy heat pump technologies to both open and confined greenhouses in California. The confined system has no external aeration and has no need for further water supply. It has a great potential to reduce the demand for natural gas, the load on the power grid, and the demand for irrigation water in greenhouse operations. It also allows plant protection without using chemical insecticides and the accumulation of carbon dioxide without aeration losses. INTRODUCTION Alternative energy sources and energy conservation practices are receiving greater attention for heating, cooling and power generation applications. To provide optimal micro-environments for plant growth, producers can use or control the number of glazing layers, insulation curtains or screens to reduce long-wave radiation losses at night, reduced ventilation rates, evaporative coolers, and shading devices to control incoming solar radiation. In addition, the limited supply of fossil fuels and the uncertainty about the oil supply in recent years has advanced the potential use of heat pumps for both heating and cooling purposes (Christensen and Santoso, 1990; Yildiz et al., 1993; Willits and Gurjer, 2004; Ebru and Arif, 2007; Hamada et al., 2007; Karlsson and Fahle’n, 2007). However, these systems involve complex tradeoffs between initial and operating costs for cooling and heating in greenhouses, plant responses to various environmental factors and the strategies used to regulate temperature, humidity and CO2 levels in the crop canopy. Special attention must be given to the operational strategies, especially in maintaining acceptable relative humidity levels. A dynamic simulation model was developed and validated to provide an accurate prediction of greenhouse energy and moisture exchanges as a function of dynamic environmental factors (Yildiz and Stombaugh, 2006a). This model was used to predict heating and cooling loads, water use, and to evaluate the operational strategies associated with heating and cooling using the proposed heat pump and a conventional system. The overall objective of this study was to compare conventional, open loop and closed loop heat pump greenhouse systems’ performances in semi-arid California, with focus especially to the confined loop heat pump system. MATERIALS AND METHODS Weather File January, April, and July weather files for San Luis Obispo (35°17’ N and 120°39’ W), California, USA were used to represent winter, spring, and summer in the simulations. Simulations were performed starting at the beginning of the fifth day and ended at the end of 29th day of the month providing 25-day simulations. All simulations were performed for the years 2005, 2006 and 2007. Greenhouse Characteristics, Operational and Control Strategies, and Analysis Using the dynamic simulation model, different greenhouse configurations were studied to determine their energy and water consumption. Table 1 shows the greenhouse and the crop characteristics used in this study. To see how different configurations of the heat pump and ventilation control affect greenhouse environmental conditions, simulations were performed under three different conditions. In a conventional greenhouse, ventilation and the crops themselves typically cool the greenhouse interior during hot days. Evaporative cooling was also provided in the conventional system to handle excess cooling loads. The heat pump system can both heat and cool keeping the inside temperature and relative humidity levels within acceptable ranges so the vegetation does not suffer from high inside relative humidity levels or low inside temperatures. In an open loop heat pump greenhouse, not only is ventilation used for cooling and for removing humidity but also one of the heat pump units acted as a dehumidifier condensing water vapor into usable water. Furthermore, the heat pump regulated inside temperature just as the conventional furnace did in the conventional system. In a closed loop heat pump system, the greenhouse was completely closed off to the outside air, allowing no ventilation for cooling or relative humidity control. Heating, cooling, ventilation and shading system specifics of the study, and the operational and control strategies were previously reported in details by Yildiz and Stombaugh (2006b). For all three years and all three seasons a total of 36 simulations were executed. Total energy and water consumption data were collected for 25-day trials. Heating, cooling, ventilation, and pump energy requirements were collected separately. Statistical analysis on these trials was performed using standard Analysis of Variance (ANOVA) (significance level of P<0.05) which analyzed if a change between configurations was significant and Tukey Simultaneous Test at a confidence level of 95% to compare the means between the treatments and to find statistically significant differences. RESULTS AND DISCUSSION Energy Consumption The mean energy consumption for heating (of three years) differed with the season and different systems (Fig. 1A). Naturally, the colder the outside weather condition was, the more heating energy was needed (i.e. winter the most, summer the least). For the conventional system, the average energy consumption over the three years was found to be 25.82, 21.11 and 10.95 MJ/m/day for winter, spring, and summer, respectively (Fig. 1A). For the open loop heat pump system, the average energy consumption over the three years was found to be 11.47, 9.55, and 5.53 MJ/m/day for winter, spring, and summer, respectively. For the confined loop heat pump system, the average energy consumption over the three years was 10.89, 10.29 and 12.42 MJ/m/day for winter, spring and summer, respectively. The average statistical comparisons between all possible pairs were conducted using the Tukey Simultaneous Test at a 95% confidence level. Data for statistical analysis was taken as a whole over all season and years. Table 2 shows that all of the presented energy means were statistically different from each other. Overall, the open loop heat pump system required the least amount of energy, followed by the confined greenhouse and then finally the conventional greenhouse having the highest energy consumption. In comparison, both types of looped heat pump greenhouses lowered energy consumption compared against the traditional method. Upon closer analysis, the confined loop heat pump system energy requirements remained relatively stable for all seasons. This was because the closed system had low cooling requirements in winter when the heating requirements were high, and the very same system had high cooling requirements in summer when the heating requirements were low. The conventional and open systems, which were open to the outside environment, required more energy during the winter and distinctly less energy in the summer. The confined system almost always needed less energy relative to the conventional system and less energy relative to the open heat pump system in winter. As seen, one of the main factors on the energy consumption was the outside weather condition. The presented study was executed using weather data from three different years (2005, 2006 and 2007). Differences in energy consumption between the years were not statistically significant. For the winter and spring data sets, the energy consumption increased over the years, meaning that the year 2006 was colder than 2005; and the year 2007 was even colder than 2006. The summer data proved that the coldest summer was in the year 2005, followed by a very warm summer in 2006, and then, relatively speaking, another cold summer in 2007. Due to the space limitations, detailed climatic information could not be provided in the article. However, for the duration of the simulation period, the mean outside temperatures of three years were 9.6, 11.5 and 16.1C in winter, spring and summer, respectively; the mean solar radiation received on a horizontal plane during daytime were 272, 396 and 466 W/m in winter, spring and summer, respectively; and the mean outside relative humidity levels were 68.5, 77.3 and 80.4% in winter, spring and summer, respectively. Water Consumption The water consumption was significantly decreased in the closed loop heat pump greenhouse system in comparison with conventional and open loop heat pump systems. For the conventional system, the average water use for transpiration over the three years was found to be 2.32, 2.12 and 2.07 MJ/m/day for winter, spring, and summer, respectively. For the open loop heat pump system, the average water use for transpiration over the three years was found to be 2.25, 2.20 and 2.29 MJ/m/day for winter, spring, and summer, respectively. For the closed loop greenhouse system, the average water use for transpiration over the three years was 0.74, 0.76 and 1.5 MJ/m/day for winter, spring and summer, respectively. Due to the high relative humidity levels maintained within the confined system, transpiration rates were relatively lower compared to those in the other two systems. In the closed heat pump greenhouse system in all three years, especially in winters, the dehumidification system maintained inside relative humidity at an average level of 85% ranging approximately between 75% and 95%. Almost all the transpire
[1]
D. Stombaugh,et al.
Dynamic Modeling of Microclimate and Environmental Control Strategies in a Greenhouse Coupled with a Heat Pump System
,
2006
.
[2]
Richard N. Christensen,et al.
An evaluation of a rankine cycle driven heat pump
,
1990
.
[3]
Yasuhiro Hamada,et al.
Improved underground heat exchanger by using no-dig method for space heating and cooling
,
2007
.
[4]
Per Fahlén,et al.
Capacity-controlled ground source heat pumps in hydronic heating systems
,
2007
.
[5]
D. P. Stombaugh,et al.
Simulated Performances of a Heat Pump System for Energy and Water Conservation in Open and Confined Greenhouse Systems
,
2006
.
[6]
Arif Hepbasli,et al.
A comparative study on exergetic assessment of two ground-source (geothermal) heat pump systems for residential applications
,
2007
.
[7]
D. H. Willits,et al.
HEAT PUMPS FOR THE HEATING AND NIGHT-COOLING OF GREENHOUSE CROPS: A SIMULATION STUDY
,
2004
.