Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults

The management reporting and assessment of glycemic control lacks standardization. The use of different methods to measure the blood glucose concentration and to report the performance of insulin treatment yields major disparities and complicates the interpretation and comparison of clinical trials. We convened a meeting of 16 experts plus invited observers from industry to discuss and where possible reach consensus on the most appropriate methods to measure and monitor blood glucose in critically ill patients and on how glycemic control should be assessed and reported. Where consensus could not be reached, recommendations on further research and data needed to reach consensus in the future were suggested. Recognizing their clear conflict of interest, industry observers played no role in developing the consensus or recommendations from the meeting. Consensus recommendations were agreed for the measurement and reporting of glycemic control in clinical trials and for the measurement of blood glucose in clinical practice. Recommendations covered the following areas: How should we measure and report glucose control when intermittent blood glucose measurements are used? What are the appropriate performance standards for intermittent blood glucose monitors in the ICU? Continuous or automated intermittent glucose monitoring - methods and technology: can we use the same measures for assessment of glucose control with continuous and intermittent monitoring? What is acceptable performance for continuous glucose monitoring systems? If implemented, these recommendations have the potential to minimize the discrepancies in the conduct and reporting of clinical trials and to improve glucose control in clinical practice. Furthermore, to be fit for use, glucose meters and continuous monitoring systems must match their performance to fit the needs of patients and clinicians in the intensive care setting.See related commentary by Soto-Rivera and Agus, http://ccforum.com/content/17/3/155

[1]  Stephane Heritier,et al.  Intensive versus conventional glucose control in critically ill patients. , 2009, The New England journal of medicine.

[2]  B. Bistrian,et al.  Intensive insulin therapy in critically ill patients. , 2002, The New England journal of medicine.

[3]  R. Jayaram,et al.  Fatal neuroglycopaenia after accidental use of a glucose 5% solution in a peripheral arterial cannula flush system , 2007, Anaesthesia.

[4]  J. Mahoney,et al.  Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management , 2007, Diabetes Care.

[5]  Hartzell V Schaff,et al.  Accuracy of roche accu-chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery. , 2007, American journal of clinical pathology.

[6]  Saxon Ridley Critical care. , 2003, Anaesthesia.

[7]  B. De Moor,et al.  LOGIC-Insulin Algorithm–Guided Versus Nurse-Directed Blood Glucose Control During Critical Illness , 2013, Diabetes Care.

[8]  Rolf Rossaint,et al.  Intensive insulin therapy and pentastarch resuscitation in severe sepsis. , 2008, The New England journal of medicine.

[9]  David E Bruns,et al.  Monte Carlo simulation in establishing analytical quality requirements for clinical laboratory tests meeting clinical needs. , 2009, Methods in enzymology.

[10]  I. Mackenzie,et al.  The metrics of glycaemic control in critical care , 2011, Intensive Care Medicine.

[11]  Michael Bailey,et al.  Hypoglycemia and outcome in critically ill patients. , 2010, Mayo Clinic proceedings.

[12]  B. Afessa,et al.  Agreement between bedside blood and plasma glucose measurement in the ICU setting. , 2005, Chest.

[13]  Johan Groeneveld,et al.  A prospective randomised multi-centre controlled trial on tight glucose control by intensive insulin therapy in adult intensive care units: the Glucontrol study , 2009, Intensive Care Medicine.

[14]  R. Jansen,et al.  SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use , 2010, Clinical chemistry and laboratory medicine.

[15]  Brian Hutton,et al.  Reliability of point-of-care testing for glucose measurement in critically ill adults* , 2005, Critical care medicine.

[16]  Rinaldo Bellomo,et al.  Variability of Blood Glucose Concentration and Short-term Mortality in Critically Ill Patients , 2006, Anesthesiology.

[17]  C. Madl,et al.  Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients* , 2011, Critical care medicine.

[18]  M Schetz,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[19]  David B Sacks,et al.  Tight glucose control in the intensive care unit: are glucose meters up to the task? , 2009, Clinical chemistry.

[20]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[21]  C. Toumazou,et al.  Glucose sensors: a review of current and emerging technology , 2009, Diabetic medicine : a journal of the British Diabetic Association.

[22]  Ameen Abu-Hanna,et al.  Glucose variability measures and their effect on mortality: a systematic review , 2011, Intensive Care Medicine.

[23]  Marc D Breton,et al.  Impact of Blood Glucose Self-Monitoring Errors on Glucose Variability, Risk for Hypoglycemia, and Average Glucose Control in Type 1 Diabetes: An In Silico Study , 2010, Journal of diabetes science and technology.

[24]  G. Beilman,et al.  Hyperglycemia in the intensive care unit: no longer just a marker of illness severity. , 2005, Surgical infections.

[25]  M. Lyon,et al.  Interference studies with two hospital-grade and two home-grade glucose meters. , 2009, Diabetes technology & therapeutics.

[26]  M. Siegel,et al.  Glucose control in the ICU--how tight is too tight? , 2009, The New England journal of medicine.

[27]  J. G. van der Hoeven,et al.  Accuracy of bedside glucose measurement from three glucometers in critically ill patients* , 2008, Critical care medicine.

[28]  G. Van den Berghe,et al.  Intensive insulin therapy in the medical ICU. , 2006, The New England journal of medicine.