Transsplenic portal catheterization combined with a jugular double-lumen catheter for pharmacokinetic and presystemic metabolization studies in pigs.

The reliability of a silicone double-lumen catheter implanted into the external jugular vein and tunnelled towards the neck region was investigated in eight pigs. Surgery was uneventful without interference with the normal homoeostasis during 8 days. After injection of amoxicillin/clavulanic acid through the distal port of the catheter, analysis of drug components in the simultaneous blood samples obtained by the proximal port and a Venoject system were comparable in one pig. Histological control of the catheterized jugular veins pointed to an acceptable tissue reaction while bacteriological examination of the tip of the catheters was negative in only three animals. A moulding of the intestinal veins was made in a pig cadaver to determine the optimal length of insertion of a silicone portal catheter from the splenic vein towards the portal vein. Surgery was straightforward in four pigs whereby the catheter was exteriorized towards the back region. No complications were encountered during and after surgery for 9 days. The technique of a double-lumen catheter placed into the jugular vein and a transsplenic portal catheter is a useful tool for the study of the pharmacokinetics and also the first-pass effect of drugs in experimental pigs.

[1]  P. de Backer,et al.  Influence of administration route on the biotransformation of amoxicillin in the pig. , 2009, Journal of veterinary pharmacology and therapeutics.

[2]  P. de Backer,et al.  Tissue depletion of amoxicillin and its major metabolites in pigs: influence of the administration route and the simultaneous dosage of clavulanic acid. , 2008, Journal of agricultural and food chemistry.

[3]  P. de Backer,et al.  Disposition and oral bioavailability of amoxicillin and clavulanic acid in pigs. , 2007, Journal of veterinary pharmacology and therapeutics.

[4]  R. Gagnon,et al.  Correlation of transcutaneous hepatic near‐infrared spectroscopy readings with liver surface readings and perfusion parameters in a piglet endotoxemic shock model , 2006, Liver international : official journal of the International Association for the Study of the Liver.

[5]  P. de Backer,et al.  Determination of clavulanic acid in calf plasma by liquid chromatography tandem mass spectrometry. , 2006, Journal of mass spectrometry : JMS.

[6]  C. Broelsch,et al.  New Surgical Technique for Portal Venous Port System in Swine , 2005, European Surgical Research.

[7]  T. Kanazu,et al.  Assessment of the hepatic and intestinal first-pass metabolism of midazolam in a CYP3A drug–drug interaction model rats , 2005, Xenobiotica; the fate of foreign compounds in biological systems.

[8]  A. Shalhav,et al.  Comparison of external catheters with subcutaneous vascular access ports for chronic vascular access in a porcine model. , 2005, Contemporary topics in laboratory animal science.

[9]  S. Agarwal,et al.  A Prospective Randomized Study to Compare Ultrasound-Guided with Nonultrasound-Guided Double Lumen Internal Jugular Catheter Insertion as a Temporary Hemodialysis Access , 2005, Renal failure.

[10]  B. Stoll,et al.  Intestinal lysine metabolism is driven by the enteral availability of dietary lysine in piglets fed a bolus meal. , 2003, American journal of physiology. Endocrinology and metabolism.

[11]  D. Chinkes,et al.  Increased tissue oxygen extraction and acidosis with progressive severity of sepsis. , 2003, The Journal of surgical research.

[12]  P. Koblik,et al.  Percutaneous ultrasound-guided trans-splenic catheterization of the portal vein in the dog. , 1999, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[13]  C. Friis,et al.  Bioavailability of amoxycillin in pigs. , 1998, Journal of veterinary pharmacology and therapeutics.

[14]  B. Stoll,et al.  Catabolism dominates the first-pass intestinal metabolism of dietary essential amino acids in milk protein-fed piglets. , 1998, The Journal of nutrition.

[15]  M. Espeland,et al.  Contribution of vascular catheter material to the pathogenesis of infection: the enhanced risk of silicone in vivo. , 1995, Journal of biomedical materials research.

[16]  J. V. Houdt,et al.  Reduction of the prodrug loperamide oxide to its active drug loperamide in the gut of rats, dogs, and humans. , 1995, Drug metabolism and disposition: the biological fate of chemicals.

[17]  M. Bosch,et al.  A portal-vein-catheterization technique in pigs and sheep, and postprandial changes of pO2, pCO2, pH, urea, ammonia, and creatinine and proteins in portal and arterial blood measured in pigs. , 1995 .

[18]  S. A. Goedegebuure,et al.  Intravenous catheterisation of conventional pigs without application of antimicrobial agents. , 1989, The Veterinary quarterly.

[19]  C. Kemp,et al.  Atrial cannulation for long-term sequential blood collection in gilts. , 1987, American journal of veterinary research.

[20]  J. Killefer,et al.  A method for chronically quantifying net absorption of nutrients and gut metabolites into hepatic portal vein in conscious swine. , 1987, Journal of animal science.

[21]  L. van Leengoed,et al.  Intravenous catheterization in pigs: an evaluation of two methods. , 1987, Zentralblatt fur Veterinarmedizin. Reihe A.

[22]  Wixson Sk,et al.  Vascular-access-port implantation for serial blood sampling in conscious swine. , 1986 .

[23]  E. Woodle,et al.  A simple technique for experimental hepatic vein catheterization in swine. , 1986, Laboratory animal science.

[24]  H. Takahashi Long-term blood-sampling technique in piglets , 1986, Laboratory animals.

[25]  H. Kitagawa,et al.  A simple catheterization from the ear vein into the jugular vein for sequential blood sampling from unrestrained pigs. , 1985, The Japanese journal of veterinary research.

[26]  S. Eykyn Infection and intravenous catheters. , 1984, The Journal of antimicrobial chemotherapy.

[27]  R. M. Vazquez,et al.  Care of the central venous catheterization site: the use of a transparent polyurethane film. , 1984, JPEN. Journal of parenteral and enteral nutrition.

[28]  Maurer Rr,et al.  Simple technique for chronic venous catheterization of swine. , 1978 .

[29]  J. Smallwood,et al.  Collection of blood from swine. , 1977, New Zealand Veterinary Journal.

[30]  Witzel Da,et al.  Implanted catheters for blood sampling in swine. , 1973 .

[31]  Z. Yao,et al.  A portal vein cannulation technique for drug discovery in mice , 2008, Lab Animal.

[32]  P. de Backer,et al.  Rapid method for the quantification of amoxicillin and its major metabolites in pig tissues by liquid chromatography-tandem mass spectrometry with emphasis on stability issues. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[33]  W. Charman,et al.  The Mucosa of the Small Intestine , 2002, Clinical pharmacokinetics.

[34]  F. Gasthuys,et al.  Repetitive intravenous catherisation for pharmacokinetic studies in pigs. , 1999 .

[35]  M. Swindle,et al.  Chronic cannulation and fistulization procedures in swine: a review and recommendations. , 1998, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[36]  D. Solomon,et al.  An in vivo method for the evaluation of catheter thrombogenicity. , 1987, Journal of biomedical materials research.

[37]  U. Paschen,et al.  Serial blood sampling from the portal and hepatic vein in conscious unrestrained miniature pigs , 1986, Research in experimental medicine. Zeitschrift fur die gesamte experimentelle Medizin einschliesslich experimenteller Chirurgie.