Symmetry Analysis of Gait between Left and Right Limb Using Cross-Fuzzy Entropy

The purpose of this paper is the investigation of gait symmetry problem by using cross-fuzzy entropy (C-FuzzyEn), which is a recently proposed cross entropy that has many merits as compared to the frequently used cross sample entropy (C-SampleEn). First, we used several simulation signals to test its performance regarding the relative consistency and dependence on data length. Second, the gait time series of the left and right stride interval were used to calculate the C-FuzzyEn values for gait symmetry analysis. Besides the statistical analysis, we also realized a support vector machine (SVM) classifier to perform the classification of normal and abnormal gaits. The gait dataset consists of 15 patients with Parkinson's disease (PD) and 16 control (CO) subjects. The results show that the C-FuzzyEn values of the PD patients' gait are significantly higher than that of the CO subjects with a p value of less than 10−5, and the best classification performance evaluated by a leave-one-out (LOO) cross-validation method is an accuracy of 96.77%. Such encouraging results imply that the C-FuzzyEn-based gait symmetry measure appears as a suitable tool for analyzing abnormal gaits.

[1]  J. Richman,et al.  Physiological time-series analysis using approximate entropy and sample entropy. , 2000, American journal of physiology. Heart and circulatory physiology.

[2]  Yunfeng Wu,et al.  Analysis of altered gait cycle duration in amyotrophic lateral sclerosis based on nonparametric probability density function estimation. , 2011, Medical engineering & physics.

[3]  Mohammad Reza Daliri,et al.  Automatic diagnosis of neuro-degenerative diseases using gait dynamics , 2012 .

[4]  Zyad Shaaban,et al.  Data Mining: A Preprocessing Engine , 2006 .

[5]  Anthony G Hudetz,et al.  Effect of volatile anesthetics on interhemispheric EEG cross-approximate entropy in the rat , 2002, Brain Research.

[6]  Jeffrey M. Hausdorff,et al.  Treadmill walking as an external pacemaker to improve gait rhythm and stability in Parkinson's disease , 2005, Movement disorders : official journal of the Movement Disorder Society.

[7]  James G Richards,et al.  A method for analyzing joint symmetry and normalcy, with an application to analyzing gait. , 2006, Gait & posture.

[8]  J B King,et al.  Gait Analysis. An Introduction , 1992 .

[9]  Wangxin Yu,et al.  Characterization of Surface EMG Signal Based on Fuzzy Entropy , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  Yunfeng Wu,et al.  Statistical Analysis of Gait Rhythm in Patients With Parkinson's Disease , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  Li Li,et al.  Stance and sensory feedback influence on postural dynamics , 2007, Neuroscience Letters.

[12]  Karl M Newell,et al.  The dynamics of resting and postural tremor in Parkinson's disease , 2000, Clinical Neurophysiology.

[13]  C. Metz,et al.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. , 1998, Statistics in medicine.

[14]  Qiang Ye,et al.  A novel approach for analysis of altered gait variability in amyotrophic lateral sclerosis , 2015, Medical & Biological Engineering & Computing.

[15]  S. Pincus,et al.  Randomness and degrees of irregularity. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[16]  S M Pincus,et al.  Approximate entropy as a measure of system complexity. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Weiting Chen,et al.  Measuring complexity using FuzzyEn, ApEn, and SampEn. , 2009, Medical engineering & physics.

[18]  J. Gracies,et al.  Long-term monitoring of gait in Parkinson's disease. , 2007, Gait & posture.

[19]  Fuyuan Liao,et al.  Multi-resolution entropy analysis of gait symmetry in neurological degenerative diseases and amyotrophic lateral sclerosis. , 2008, Medical engineering & physics.

[20]  Jeffrey M. Hausdorff,et al.  Footswitch system for measurement of the temporal parameters of gait. , 1995, Journal of biomechanics.

[21]  Jun Ye,et al.  Fault diagnosis of turbine based on fuzzy cross entropy of vague sets , 2009, Expert Syst. Appl..

[22]  T. Hermana,et al.  Gait instability and fractal dynamics of older adults with a “ cautious ” gait : why do certain older adults walk fearfully ? , 2005 .

[23]  R. Song,et al.  Characterizing gait asymmetry via frequency sub-band components of the ground reaction force , 2015, Biomed. Signal Process. Control..

[24]  Roberto Hornero,et al.  Cross Approximate Entropy Analysis of Nocturnal Oximetry Signals in the Diagnosis of the Obstructive Sleep Apnea Syndrome , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Jeffrey M. Hausdorff,et al.  Gait asymmetry in patients with Parkinson’s disease and elderly fallers: when does the bilateral coordination of gait require attention? , 2007, Experimental Brain Research.

[26]  P. Cavanagh,et al.  Increased variability of continuous overground walking in neuropathic patients is only indirectly related to sensory loss. , 2001, Gait & posture.

[27]  M. Hallett,et al.  Freezing of gait: moving forward on a mysterious clinical phenomenon , 2011, The Lancet Neurology.

[28]  Jeffrey M. Hausdorff,et al.  Is walking a random walk? Evidence for long-range correlations in stride interval of human gait. , 1995, Journal of applied physiology.

[29]  Hsien-Tsai Wu,et al.  Multiscale Cross-Approximate Entropy Analysis as a Measure of Complexity among the Aged and Diabetic , 2013, Comput. Math. Methods Medicine.

[30]  Nicholas Wickström,et al.  A new measure of movement symmetry in early Parkinson's disease patients using symbolic processing of inertial sensor data , 2011, IEEE Transactions on Biomedical Engineering.

[31]  Nicholas Wickström,et al.  A Symbol-Based Approach to Gait Analysis From Acceleration Signals: Identification and Detection of Gait Events and a New Measure of Gait Symmetry , 2010, IEEE Transactions on Information Technology in Biomedicine.

[32]  B. Nigg,et al.  Use of force platform variables to quantify the effects of chiropractic manipulation on gait symmetry. , 1987, Journal of manipulative and physiological therapeutics.

[33]  W. Ondo,et al.  Ambulatory monitoring of freezing of gait in Parkinson's disease , 2008, Journal of Neuroscience Methods.

[34]  Masayoshi Tomizuka,et al.  Gait phase analysis based on a Hidden Markov Model , 2011 .

[35]  M. Arif,et al.  Complexity analysis of stride interval time series by threshold dependent symbolic entropy , 2006, European Journal of Applied Physiology.

[36]  S. Simon Gait Analysis, Normal and Pathological Function. , 1993 .

[37]  G. Giakas,et al.  Time and frequency domain analysis of ground reaction forces during walking: an investigation of variability and symmetry , 1997 .

[38]  F. Prince,et al.  Symmetry and limb dominance in able-bodied gait: a review. , 2000, Gait & posture.

[39]  Xin Chen,et al.  Cross-fuzzy entropy: A new method to test pattern synchrony of bivariate time series , 2010, Inf. Sci..

[40]  Jeffrey M. Hausdorff,et al.  Gait variability and basal ganglia disorders: Stride‐to‐stride variations of gait cycle timing in parkinson's disease and Huntington's disease , 1998, Movement disorders : official journal of the Movement Disorder Society.