Seamless Transfer of Single-Phase Grid-Interactive Inverters Between Grid-Connected and Stand-Alone Modes

This paper presents a novel seamless transfer of single-phase grid-interactive inverters between grid-connected and stand-alone modes. The grid-connected inverter should operate in grid-tied and off-grid modes in order to provide power to the emergency load during system outages. However, the grid current controller and the output voltage controller are switched between the two modes, so the outputs of both controllers may not be equal during the transfer instant, which will cause the current or voltage spikes during the switching process. The transfer between the two controllers does not exist in the proposed method. In grid-tied mode, the voltage controller is used for compensating the filter capacitor current, and the current controller is used to control the grid current. In stand-alone mode, the voltage controller is used to regulate the output voltage, whereas the output of the current controller is zero. With the proposed control method, the seamless transfer can be achieved between both modes, even in polluted grid voltage. The principle and realization conditions of the control methods at both modes are analyzed. The detailed process of the seamless transfer between the two modes is illustrated. Finally, the simulation and experimental results verify the theoretical analysis.

[1]  J.W. Kolar,et al.  Center-Point Voltage Balancing of Hysteresis Current Controlled Three-Level PWM Rectifiers , 2008, IEEE Transactions on Power Electronics.

[2]  Sewan Choi,et al.  Indirect Current Control Algorithm for Utility Interactive Inverters in Distributed Generation Systems , 2008, IEEE Transactions on Power Electronics.

[3]  Lie Xu,et al.  Improved Direct Power Control of Grid-Connected DC/AC Converters , 2009, IEEE Transactions on Power Electronics.

[4]  Yangguang Yan,et al.  Dual-Buck Full-Bridge Inverter With Hysteresis Current Control , 2009, IEEE Transactions on Industrial Electronics.

[5]  F. Blaabjerg,et al.  Flexible control of small wind turbines with grid failure detection operating in stand-alone and grid-connected mode , 2004, IEEE Transactions on Power Electronics.

[6]  M. Hoyerby,et al.  Ultrafast Tracking Power Supply With Fourth-Order Output Filter and Fixed-Frequency Hysteretic Control , 2008, IEEE Transactions on Power Electronics.

[7]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[8]  O. Vodyakho,et al.  Three-Level Inverter-Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems , 2009, IEEE Transactions on Power Electronics.

[9]  E.C. Tatakis,et al.  Optimum Design of the Current-Source Flyback Inverter for Decentralized Grid-Connected Photovoltaic Systems , 2008, IEEE Transactions on Energy Conversion.

[10]  Ke-Horng Chen,et al.  Adaptive Window Control (AWC) Technique for Hysteresis DC–DC Buck Converters With Improved Light and Heavy Load Performance , 2009, IEEE Transactions on Power Electronics.

[11]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[12]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[13]  J. Lunze,et al.  Design of Generalized Hysteresis Controllers for DC–DC Switching Power Converters , 2009, IEEE Transactions on Power Electronics.

[14]  Sewan Choi,et al.  A Low Cost Utility Interactive Inverter for Residential Fuel Cell Generation , 2007, IEEE Transactions on Power Electronics.

[15]  Yangguang Yan,et al.  A novel hysteresis current controlled dual buck half bridge inverter , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[16]  Quan Li,et al.  A Review of the Single Phase Photovoltaic Module Integrated Converter Topologies With Three Different DC Link Configurations , 2008, IEEE Transactions on Power Electronics.

[17]  V. Agarwal,et al.  A Single-Stage Grid Connected Inverter Topology for Solar PV Systems With Maximum Power Point Tracking , 2007, IEEE Transactions on Power Electronics.

[18]  Ned Mohan,et al.  Seamless transfer of grid-connected PWM inverters between utility-interactive and stand-alone modes , 2002, APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335).

[19]  J. Bordonau,et al.  Topologies of single-phase inverters for small distributed power generators: an overview , 2004, IEEE Transactions on Power Electronics.

[20]  Robert W. Erickson,et al.  Fundamentals of Power Electronics , 2001 .

[21]  A. Shukla,et al.  Improved Multilevel Hysteresis Current Regulation and Capacitor Voltage Balancing Schemes for Flying Capacitor Multilevel Inverter , 2008, IEEE Transactions on Power Electronics.

[22]  Jan T. Bialasiewicz,et al.  Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey , 2006, IEEE Transactions on Industrial Electronics.

[23]  Yangguang Yan,et al.  Control Strategy for Series and Parallel Output Dual-Buck Half Bridge Inverters Based on DSP Control , 2009 .