Adding Two New Contact Circumstances to 'Merged Phantom Tool' and a Technique to Convert Structure Information Segmented by the Carimas Software Into Geant4 Geometry.

Two new contact circumstances called 'stand-lie' and 'front-rear' are implemented to the merged phantom tool. To allow more flexibility for users when they calculate the dose for a volume of interest (VOI) with arbitrary geometry, an optional utility to convert segmented structure information from the CARIMAS software into parallel geometry of GEANT4 is provided. The effective dose for a person who has been in contact with a male patient being treated for thyroid cancer with 131I is calculated for four circumstances: opposite, side by side, stand-lie and front-rear. The biggest dose is the 'opposite' circumstance and the smallest one is the 'stand-lie' circumstance. Using the dose distribution in the patient's body and applying the right circumstance should be done to optimise the dose calculation for the contact person.

[1]  Christoph Hoeschen,et al.  Radiation Protection in Nuclear Medicine , 2012 .

[2]  M. Bartlett Estimated dose from diagnostic nuclear medicine patients to people outside the Nuclear Medicine department. , 2013, Radiation protection dosimetry.

[3]  Michele Larobina,et al.  Medical Image File Formats , 2014, Journal of Digital Imaging.

[4]  Ernest Frimpong Asamoah,et al.  Radiation safety in the treatment of patients with thyroid diseases by radioiodine 131I : practice recommendations of the American Thyroid Association. , 2011, Thyroid : official journal of the American Thyroid Association.

[5]  Xianping Lu,et al.  Follow-up and evaluation of the pregnancy outcome in women of reproductive age with Graves’ disease after 131Iodine treatment , 2016, Journal of radiation research.

[6]  J. Apostolakis,et al.  Parallel geometries in Geant4: Foundation and recent enhancements , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[7]  Margaret M Fleming,et al.  ABM Clinical Protocol #30: Radiology and Nuclear Medicine Studies in Lactating Women. , 2019, Breastfeeding medicine : the official journal of the Academy of Breastfeeding Medicine.

[8]  M. A. Cortés-Giraldo,et al.  Recent developments in GEANT4 , 2016 .

[9]  Uslu Besli Lebriz,et al.  RADIATION DOSE OF CAREGIVERS COULD BE REDUCED IN THYROID CARCINOMA PATIENTS REQUIRING HIGH DOSE OF RADIOACTIVE IODINE: A CASE REPORT , 2016 .

[10]  O. AndersonPhilip,et al.  ABM Clinical Protocol #31: Radiology and Nuclear Medicine Studies in Lactating Women , 2019 .

[11]  J. Siegel,et al.  COMPARISON OF POINT, LINE AND VOLUME DOSE CALCULATIONS FOR EXPOSURE TO NUCLEAR MEDICINE THERAPY PATIENTS , 2011, Health physics.

[12]  K. S. Song,et al.  A virtual reality application for geometry classes , 2002, J. Comput. Assist. Learn..

[13]  von MüllerFriederike,et al.  Evaluation of Fear of Radiation and Isolation Before and After Radioiodine Therapy , 2014 .

[14]  Nguyen Thi Phuong Thao,et al.  Calculating equivalent dose received from a patient undergoing nuclear medicine procedure by merge phantoms tool and GAMOS/Geant4 6.0.0 software. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[15]  R. Leggett,et al.  Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment. , 2015, Medical physics.

[16]  J. Ejeh,et al.  Radiation Levels from Toilets Used By Patients Injected with 99mTc-based Radiopharmaceuticals in Ibadan , 2014, Molecular imaging and radionuclide therapy.

[17]  Julie Barnett,et al.  Information to accompany patients undergoing nuclear medicine procedures: Report 416 , 2006 .