Five Year Results of Hydroxyapatite Coated Hip System: Early Severe Wear and Acetabular Osteolysis

Purpose: To assess the midterm results of the hydroxyapatite hip system with acetabular cups, with particular emphasis upon cup wearand loosening, using a computer assisted-3 dimensional technique. Materials and Methods: From March 1992 to December 1996, 52 patients (61 hips) were available for inclusion in this study after an average duration of follow up of 6 years and 4 months. Clinical evaluation was performed using the Harris hip scoring system. Initial postoperative and long term follow up films were digitized, and 2 dimensional linear and 3 dimensional wear was measured by using a computer assisted-3 dimensional technique. Acetabular bone changes are described using previous published methods. Results: An analysis of the clinical results showed a mean Harris hip score of 47.2 points preoperatively and 89.8 points at the final visit. The mean polyethylene 3D-linear wear rate was 0.26 mm/year and mean volumetric wear rate was 105.9 /year. In 16 hips (26.2%) the linear wear rate was more than 0.3 mm/year (0.30-0.74 mm/year). Osteolytic changes of the acetabulum were recorded in 51% around acetabular cups, in which considerable wear of the acetabular polyethylene was evident by the five-year radiographic findings. Conclusion: Midterm results of hydroxyapatite coated acetabular cups were disappointing in terms of acetabular cup and liner wear, despite early accelerated bone remodeling by hydroxyapatite and excellent early clinical results.

[1]  C. Engh,et al.  Characterization of Long-Term Femoral-Head-Penetration Rates: Association with and Prediction of Osteolysis* , 2000, The Journal of bone and joint surgery. American volume.

[2]  U. Aebi,et al.  Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. , 1998, The Journal of bone and joint surgery. British volume.

[3]  T. Mallory Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial. , 1998, The Journal of bone and joint surgery. American volume.

[4]  J. Galante,et al.  Primary cementless acetabular reconstruction in patients younger than 50 years old. 7- to 11-year results. , 1997, Clinical orthopaedics and related research.

[5]  R. Lemaire,et al.  Hydroxyapatite coating on a cementless polyethylene cup: experience with the RM cup , 1995 .

[6]  R. Gustilo,et al.  Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? , 1995, Clinical orthopaedics and related research.

[7]  T P Schmalzried,et al.  The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. , 1994, The Journal of bone and joint surgery. American volume.

[8]  S. Medendorp,et al.  An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous, and cemented femoral components. , 1994, Clinical orthopaedics and related research.

[9]  M. Bombelli,et al.  Is the RM- Uncemented Coated Acetabular Cup a Reliable Component in Total Hip Replacement? , 1993 .

[10]  R. Bloebaum,et al.  Osteolysis from a press-fit hydroxyapatite-coated implant. A case study. , 1993, The Journal of arthroplasty.

[11]  K. Bachus,et al.  Postmortem comparative analysis of titanium and hydroxyapatite porous-coated femoral implants retrieved from the same patient. A case study. , 1993, The Journal of arthroplasty.

[12]  Y.H. Kim,et al.  Uncemented porous-coated anatomic total hip replacement , 1993 .

[13]  W. E. Anspach,et al.  A prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 2-5-year results. , 1992, The Journal of arthroplasty.

[14]  W. Capello,et al.  Hydroxylapatite‐Coated Hip Implants Multicenter Three‐Year Clinical and Roentgenographic Results , 1992, Clinical orthopaedics and related research.

[15]  R. Rothman,et al.  Cemented versus cementless total hip arthroplasty. A critical review. , 1990, Clinical orthopaedics and related research.

[16]  E. Morscher,et al.  Cementless uncoated polyethylene acetabular components in total hip replacement. Review of five- to 10-year results. , 1990, The Journal of bone and joint surgery. British volume.

[17]  C. Engh,et al.  Evaluation of cementless acetabular component migration. An experimental study. , 1989, The Journal of arthroplasty.

[18]  R. Brand,et al.  Total hip acetabular component position affects component loosening rates. , 1988, Clinical orthopaedics and related research.

[19]  C. Klein,et al.  Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. , 1987, Clinical orthopaedics and related research.

[20]  J. Charnley,et al.  Radiological demarcation of cemented sockets in total hip replacement. , 1976, Clinical orthopaedics and related research.