Entwicklung und Erprobung eines elektrokatalytischen Glucosesensors für die Diabetes-Therapie - Development and Evaluation of an Electrocatalytic Glucose Sensor for Diabetes Therapy

For the continuous measurement of glucose levels in vivo, an electrocatalytic glucose sensor has been developed. Electrochemical determination of the glucose concentration is effected by measurement of the impedance, which at given potentials is directly dependent on the glucose concentration in the solution. For evaluation and determination of long-term stability, the sensor was first implanted in the carotid artery in the form of a flow-through cell, and was later inserted into the vena cava of a sheep in the form of a catheter. Sensor response was checked periodically by performing glucose tolerance tests. During the implantation period, we also tested the sensitivity of the sensor towards various blood components and medicaments. By adapting sensor calibration, it proved possible to suppress these cross-sensitivity effects. The flow-through cell type of sensor remained functional for up to 71 days post-implantation. So far, data for the catheter-type sensor cover an indwelling time of up to 30 days.

[1]  G Richter,et al.  Metal-oxygen and glucose-oxygen cells for implantable devices. , 1974, Biomedical engineering.

[2]  W. Zingg,et al.  An Artificial Endocrine Pancreas , 1974, Diabetes.

[3]  F. Sturm,et al.  253 - Development of an Implantable Electrocatalytic Glucose Sensor , 1978 .

[4]  F. Sturm,et al.  The performance of glucose electrodes and the characteristics of different biofuel cell constructions , 1976 .

[5]  U. Gebhardt,et al.  Development and Present Status of an Electrocatalytic Glucose Sensor , 1982, Diabetes Care.

[6]  C. H. Hamann,et al.  The electrooxidation of glucose in phosphate buffer solutions , 1979 .

[7]  G. Luft,et al.  Electrochemical behavior of amino acids and their influence on the anodic oxidation of glucose in neutral media. , 1978, Biomaterials, medical devices, and artificial organs.

[8]  S. Saeger,et al.  Electrocatalytic glucose sensor. , 1994, Medical & biological engineering & computing.

[9]  W Kerner,et al.  Use of artificial pancreas and portable insulin infusion pumps in diabetes therapy: past, present, and future. , 1985, Artificial organs.

[10]  Glucose measurements by electrocatalytic sensor in the extracorporeal blood circulation of a sheep , 1990 .

[11]  A H Clemens,et al.  The artificial beta cell--a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). , 1974, Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme.

[12]  W. Schenk,et al.  Does Physiological Blood Glucose Control Require an Adaptive Control Strategy? , 1987, IEEE Transactions on Biomedical Engineering.

[13]  C. Colton,et al.  Electrochemical Glucose Oxidation on a Platinized Platinum Electrode in Krebs‐Ringer Solution III . Effect of Urea , 1979 .