Motion correction based on an appropriate system matrix for statistical reconstruction of respiratory-correlated PET acquisitions

Respiratory motion correction in positron emission tomography (PET) seeks to incorporate motion information into an image reconstruction algorithm by using the full counting statistics of an acquisition to generate a single, motion-free volume. Here, we present a motion-incorporated ordered subsets expectation maximization (MOSEM) reconstruction based on a device-dedicated tomographic projector in which each matrix element is calculated directly from the voxels' Cartesian coordinates alone. The motion is corrected by updating this projector as a function of the respiratory level. The performance of the reconstruction method was investigated with three datasets: two simulations of a transaxially or axially moving lesion on a patient acquisition and a third acquisition of a moving sphere. After the 16th sub-iteration, the normalized mean square error (NMSE, with a motionless acquisition as reference) was 0.20 for the non-corrected (ungated) image and 0.01 for the MOSEM image with transaxial motion simulation. Likewise, NMSE was 0.30 for the ungated image and 0.03 for MOSEM image with axial motion simulation. For the phantom, ungated reconstruction yielded an error of 0.78, whereas MOSEM yielded 0.43. The error reduction resulted from enhancement and reduced spreading of the moving uptake. Our results show that MOSEM reconstruction yields motion-corrected images which are similar to motionless reference images.

[1]  D. Berdichevsky,et al.  Improved Methods for Image Registration , 1996, NeuroImage.

[2]  E. Gravier,et al.  Motion-compensated reconstruction of tomographic image sequences , 2003, Proceedings 2003 International Conference on Image Processing (Cat. No.03CH37429).

[3]  J. Bowsher,et al.  Simultaneous reconstruction and motion estimation for gated cardiac ECT , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[4]  Tomio Inoue,et al.  Deep-Inspiration Breath-Hold PET/CT of Lung Cancer: Maximum Standardized Uptake Value Analysis of 108 Patients , 2008, Journal of Nuclear Medicine.

[5]  P.M. Bloomfield,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[6]  Vladimir Y. Panin,et al.  Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.

[7]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[8]  M E Phelps,et al.  Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution , 1982, Journal of computer assisted tomography.

[9]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[10]  A. Rahmim,et al.  Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach , 2004, IEEE Transactions on Nuclear Science.

[11]  M. Casey,et al.  PET reconstruction with system matrix derived from point source measurements , 2004, IEEE Transactions on Nuclear Science.

[12]  D. Visvikis,et al.  Respiratory synchronized CT image generation from 4D PET acquisitions , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[13]  A. Pevsner,et al.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Loïc Fin,et al.  Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[15]  Lei Xing,et al.  Model-based image reconstruction for four-dimensional PET. , 2006, Medical physics.

[16]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[17]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[18]  A J Reader,et al.  Respiratory motion correction for PET oncology applications using affine transformation of list mode data , 2007, Physics in medicine and biology.

[19]  Ronald J. Jaszczak,et al.  Three-dimensional motion estimation with image reconstruction for gated cardiac ECT , 2003 .

[20]  Roberta Matheoud,et al.  Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  Lei Xing,et al.  Reducing respiratory motion artifacts in positron emission tomography through retrospective stacking. , 2006, Medical physics.

[22]  R. Huesman,et al.  Four-dimensional processing of deformable cardiac PET data , 2000, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis. MMBIA-2000 (Cat. No.PR00737).

[23]  Weiguo Lu,et al.  Tomographic motion detection and correction directly in sinogram space. , 2002, Physics in medicine and biology.

[24]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[25]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[26]  Heiko Schöder,et al.  Deep-inspiration breath-hold PET/CT of the thorax. , 2007, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[27]  J. Fessler,et al.  Joint estimation of image and deformation parameters in motion-corrected PET , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[28]  J Daouk,et al.  Respiratory-gated positron emission tomography and breath-hold computed tomography coupling to reduce the influence of respiratory motion: Methodology and feasibility , 2009, Acta radiologica.

[29]  Pascal Bailly,et al.  A practical, semi-experimental system matrix for 2-D PET image reconstruction: Comparison with a geometrical model , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[30]  Lars Stegger,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2003 .

[31]  G Malandain,et al.  Model-based respiratory motion compensation for emission tomography image reconstruction , 2007, Physics in medicine and biology.