A comprehensive evaluation of commonly used accelerometer energy expenditure and MET prediction equations

Numerous accelerometers and prediction methods are used to estimate energy expenditure (EE). Validation studies have been limited to small sample sizes in which participants complete a narrow range of activities and typically validate only one or two prediction models for one particular accelerometer. The purpose of this study was to evaluate the validity of nine published and two proprietary EE prediction equations for three different accelerometers. Two hundred and seventy-seven participants completed an average of six treadmill (TRD) (1.34, 1.56, 2.23 ms−1 each at 0 and 3% grade) and five self-paced activities of daily living (ADLs). EE estimates were compared with indirect calorimetry. Accelerometers were worn while EE was measured using a portable metabolic unit. To estimate EE, 4 ActiGraph prediction models were used, 5 Actical models, and 2 RT3 proprietary models. Across all activities, each equation underestimated EE (bias −0.1 to −1.4 METs and −0.5 to −1.3 kcal, respectively). For ADLs EE was underestimated by all prediction models (bias −0.2 to −2.0 and −0.2 to −2.8, respectively), while TRD activities were underestimated by seven equations, and overestimated by four equations (bias −0.8 to 0.2 METs and −0.4 to 0.5 kcal, respectively). Misclassification rates ranged from 21.7 (95% CI 20.4, 24.2%) to 34.3% (95% CI 32.3, 36.3%), with vigorous intensity activities being most often misclassified. Prediction equations did not yield accurate point estimates of EE across a broad range of activities nor were they accurate at classifying activities across a range of intensities (light <3 METs, moderate 3–5.99 METs, vigorous ≥6 METs). Current prediction techniques have many limitations when translating accelerometer counts to EE.

[1]  D R Bassett,et al.  A new 2-regression model for the Actical accelerometer , 2007, British Journal of Sports Medicine.

[2]  B E Ainsworth,et al.  Validity of four motion sensors in measuring moderate intensity physical activity. , 2000, Medicine and science in sports and exercise.

[3]  P. Freedson,et al.  Amount of time spent in sedentary behaviors in the United States, 2003-2004. , 2008, American journal of epidemiology.

[4]  L. Mâsse,et al.  Physical activity in the United States measured by accelerometer. , 2008, Medicine and science in sports and exercise.

[5]  D. Heil,et al.  VALIDATION OF ENERGY EXPENDITURE PREDICTION ALGORITHMS IN ADULTS USING THE ACTICAL ELECTRONIC ACTIVITY MONITOR , 2003 .

[6]  D. Bassett,et al.  Estimating energy expenditure using accelerometers , 2006, European Journal of Applied Physiology.

[7]  D. Nieman,et al.  A new handheld device for measuring resting metabolic rate and oxygen consumption. , 2003, Journal of the American Dietetic Association.

[8]  C Perret,et al.  Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise. , 2006, International journal of sports medicine.

[9]  Physical Activity Guidelines Advisory Committee report, 2008. To the Secretary of Health and Human Services. Part A: executive summary. , 2009, Nutrition reviews.

[10]  J F Sallis,et al.  Assessment of physical activity by self-report: status, limitations, and future directions. , 2000, Research quarterly for exercise and sport.

[11]  John Staudenmayer,et al.  An artificial neural network to estimate physical activity energy expenditure and identify physical activity type from an accelerometer. , 2009, Journal of applied physiology.

[12]  J. B. Weir New methods for calculating metabolic rate with special reference to protein metabolism , 1949, The Journal of physiology.

[13]  G. Cavagna,et al.  The sources of external work in level walking and running. , 1976, The Journal of physiology.

[14]  Charles E Matthew,et al.  Calibration of accelerometer output for adults. , 2005, Medicine and science in sports and exercise.

[15]  D. Heil Predicting Activity Energy Expenditure Using the Actical® Activity Monitor , 2006, Research quarterly for exercise and sport.

[16]  B. Ainsworth,et al.  Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. , 2000, Medicine and science in sports and exercise.

[17]  J. Sallis,et al.  Assessment of Physical Activity by Self-Report: Status, Limitations, and Future Directions , 2000, Research quarterly for exercise and sport.

[18]  Scott E Crouter,et al.  A novel method for using accelerometer data to predict energy expenditure. , 2006, Journal of applied physiology.

[19]  J. Roitman,et al.  ACSM's Resource Manual for Guidelines for Exercise Testing and Prescription , 1998 .

[20]  J. Shaw,et al.  Objectively Measured Sedentary Time, Physical Activity, and Metabolic Risk , 2007, Diabetes Care.

[21]  P. Schantz,et al.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method , 2010, European Journal of Applied Physiology.

[22]  Yves Schutz,et al.  Metabolic equivalent: one size does not fit all. , 2005, Journal of applied physiology.

[23]  P S Freedson,et al.  Calibration of the Computer Science and Applications, Inc. accelerometer. , 1998, Medicine and science in sports and exercise.

[24]  Leena Choi,et al.  Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers , 2008, Obesity.

[25]  John Staudenmayer,et al.  Errors in MET estimates of physical activities using 3.5 ml x kg(-1) x min(-1) as the baseline oxygen consumption. , 2010, Journal of physical activity & health.