Improving flow and spillage characteristics of range hoods by using an inclined air-curtain technique.

The current study developed a new type of range hood, which was termed an 'inclined air-curtain range hood', in order to improve the flow and performance of the conventionally used wall-mounted range hood. The flow characteristics and oil mist spillages of air-curtain and conventional range hoods under the influences of both a mannequin presence and a simulated walk-by motion were experimentally examined. The study examined flow patterns by using a laser-light-sheet-assisted smoke-flow visualization technique and diagnosed spillages by using the tracer gas concentration test method. A mannequin presented in front of the conventional hood induced turbulent dispersion of oil mists toward the chest and nose of the mannequin owing to the complex interaction among the suction, wake, and wall effect, while the inclined air-curtain hood presented excellent hood performance by isolating the oil mists from the mannequin with an air curtain and therefore could reduce spillages out into the atmosphere and the mannequin's breathing zone. Both flow visualization and the tracer gas test indicated that the air-curtain hood had excellent 'robustness' over the conventional hood in resisting the influence of walk-by motion. The air-curtain technique could drastically improve the flow characteristics and performance of the range hood by consuming less energy.

[1]  R F Huang,et al.  Aerodynamic characteristics and design guidelines of push-pull ventilation systems. , 2005, The Annals of occupational hygiene.

[2]  Robert Jennings Heinsohn Industrial Ventilation: Engineering Principles , 1991 .

[3]  R. Huang,et al.  Airborne nanoparticle exposures while using constant-flow, constant-velocity, and air-curtain-isolated fume hoods. , 2010, The Annals of occupational hygiene.

[4]  Rong Fung Huang,et al.  Flow and performance of an air-curtain biological safety cabinet. , 2009, The Annals of occupational hygiene.

[5]  Rong Fung Huang,et al.  Effects of mannequin and walk-by motion on flow and spillage characteristics of wall-mounted and jet-isolated range hoods. , 2010, The Annals of occupational hygiene.

[6]  Rong Fung Huang,et al.  Effects of walk-by and sash movement on contaminant leakage of air curtain-isolated fume hood. , 2007, Industrial health.

[7]  R F Huang,et al.  Capture envelopes of rectangular hoods in cross drafts. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.

[8]  M R Flynn,et al.  Empirical validation of theoretical velocity fields into flanged circular hoods. , 1987, American Industrial Hygiene Association journal.

[9]  Gustav Victor Lachmann,et al.  Boundary layer and flow control: its principles and application , 1961 .

[10]  R. Huang,et al.  The capture envelope of a flanged circular hood in cross drafts. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.

[11]  D. Tritton,et al.  Physical Fluid Dynamics , 1977 .

[12]  R F Huang,et al.  Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics. , 2007, The Annals of occupational hygiene.

[13]  W. C. L. Hemeon,et al.  Plant and Process Ventilation , 1963 .

[14]  R. P. Benedict,et al.  ASME Measurement Uncertainty , 1985 .