Various issues relating to computational fluid dynamics simulations of carotid bifurcation flow based on models reconstructed from three-dimensional ultrasound images

Abstract Computational fluid dynamics (CFD) flow simulation techniques have the potential to enhance understanding of how haemodynamic factors are involved in atherosclerosis. Recently, three-dimensional ultrasound has emerged as an alternative to other three-dimensional imaging techniques, such as magnetic resonance angiography (MRA). The method can be used to generate accurate vascular geometry suitable for CFD simulations and can be coupled with Doppler ultrasound to provide physiologically realistic flow boundary conditions. However, there are various ways to utilize the flow data acquired, possibly leading to different results regarding both flow and wall shear stress patterns. A disadvantage of three-dimensional ultrasound for imaging the carotid bifurcation has been established as being the scanning limitation of the jawbone position. This may make artificial extensions of the internal and/or external carotid arteries necessary, which in turn may influence the predicted flow patterns. Flow simulations were carried out for three outflow calculation schemes as well as four geometries with different extensions to the carotid daughter vessels. It was found that variation of flow patterns was more strongly influenced by the outflow conditions than by the extensions of the daughter vessels. Consequently, it is recommended that for future CFD simulations of carotid flow using three-dimensional ultrasound data, the outflow boundary conditions should rely on the most accurate measurement available, and flow data recorded in the common and internal carotid are considered more reliable than data from the external carotid. Even though the extended lengths of the daughter vessels have insignificant effects on the predicted haemodynamic parameters, it would be a safer option to extend the internal carotid by approximately three times the diameter of the common carotid artery.

[1]  D C Barratt,et al.  Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging. , 2001, Ultrasound in medicine & biology.

[2]  A D Augst,et al.  Accuracy and reproducibility of CFD predicted wall shear stress using 3D ultrasound images. , 2003, Journal of biomechanical engineering.

[3]  C Kleinstreuer,et al.  Simulation of particle-hemodynamics in a partially occluded artery segment with implications to the initiation of microemboli and secondary stenoses. , 1998, Journal of biomechanical engineering.

[4]  J. Waterton,et al.  Volumetric assessment of carotid artery bifurcation using freehand-acquired, compound 3D ultrasound. , 1999, The British journal of radiology.

[5]  C Kleinstreuer,et al.  Relation between non-uniform hemodynamics and sites of altered permeability and lesion growth at the rabbit aorto-celiac junction. , 1999, Atherosclerosis.

[6]  Dean Colin Barratt Quantification of Carotid Artery Disease using Three-dimensional Ultrasound Imaging , 2002 .

[7]  A D Hughes,et al.  Flow in carotid bifurcations: effect of the superior thyroid artery. , 1999, Medical engineering & physics.

[8]  Michael M. Resch,et al.  Numerical flow studies in human carotid artery bifurcations: basic discussion of the geometric factor in atherogenesis. , 1990, Journal of biomedical engineering.

[9]  T. Nelson,et al.  Three-dimensional ultrasound imaging. , 1998, Ultrasound in medicine & biology.

[10]  M S van Leeuwen,et al.  CT angiography: application to the evaluation of carotid artery stenosis. , 1993, Radiology.

[11]  Xiao Yun Xu,et al.  CFD model of a human carotid artery bifurcation reconstructed from 3D ultrasound data , 2001 .

[12]  A D Hughes,et al.  Blood flow and vessel mechanics in a physiologically realistic model of a human carotid arterial bifurcation. , 2000, Journal of biomechanics.

[13]  A. Hughes,et al.  Reconstruction of blood flow patterns in a human carotid bifurcation: A combined CFD and MRI study , 2000, Journal of magnetic resonance imaging : JMRI.

[14]  D. Ku,et al.  Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. , 1988, Archives of pathology & laboratory medicine.

[15]  B. Rutt,et al.  Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. , 1998, Journal of vascular surgery.

[16]  D C Barratt,et al.  Optimisation and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries. , 2001, Ultrasound in medicine & biology.