Gradient-based impedance synthesis for breast and lung cancer cell screening deploying planar and nano-structured electrodes

World Health Organization articulated 9.8 million casualties globally in 2018 due to cancer. Cancer, as the world's second most fatal disease, can be recuperated well if diagnosed at an early stage. In this work, a gradient-based impedance synthesis of normal and cancerous cells of breast and lungs, is demonstrated numerically for early-stage cancer detection. Low-voltage single-cell level examination is employed for indomitable diagnosis. MCF-7 and MCF-10A are utilized as breast cancer and breast normal cells, respectively; likewise, SK-MES and NL-20 are utilized as lung cancer and lung normal cell. Pre-examination numerical setup validity ensured with multiple test regimes. Micro-scaled planar and nano-structured electrodes are employed individually to witness the effect of the electrode's structure during electrical impedance examination of cancer and non-cancer cell. Frequency range, at which differential impedance effect is found detectable, for breast and lung cancer cell pairs is determined to be 107 Hz and 108 Hz, respectively. By surpassing the conventional impedance spectroscopy with tedious data fitting formalities, the gradient synthesis technique for cancer detection is introduced. The gradient synthesis for cancer detection is found independent of electrode shape effect. Gradient for breast cancer cell is found to be 2 times greater than the normal breast cell while for lung cancer cell it is found to be 1.5 times greater than the normal lung cell. Our results suggest that as the frequency of applied electrical stimulus increases, impedance of cancerous cell falls at the rate almost double than its counterpart normal cell. This work provides a theoretical basis for further experimental exploration of gradient-based impedance synthesis in cancer therapy and serves as a design tool for performance optimization. Figure 1 (a) Represents electrical Impedance analysis of breast normal cell MCF-10A and breast cancer cell MCF-7 using micro-scaled planar and nano-structured electrodes. (b) Gradient impedance synthesis performed, for breast normal cell (MCF-10A) and breast cancer cell (MCF-7) likewise for lungs normal cell (NL-20) and lungs cancer cell (SK-MES), which assures clear differential effect for cancer screening. Surpassing the conventional and tedious data fitting impedance spectroscopies, a novel gradient-based impedance spectroscopy for early cancer detection is introduced. It clearly detects cancer without any data fitting formalities to find parameter of identification. Planar and nano structure electrodes are used to witness the impact of electrode shape on cell impedance. Breast normal MCF-10A and cancer cell MCF-7 as well as lungs normal NL-20 and cancer cell SK-MES are examined to reflect the efficacy of our work. Single cell level examination is performed for authenticated results.

[1]  E. Diamandis,et al.  An integrated cell line-based discovery strategy identified follistatin and kallikrein 6 as serum biomarker candidates of breast carcinoma. , 2016, Journal of proteomics.

[2]  Saeid Movahed,et al.  Microfluidics cell electroporation , 2011 .

[3]  K. Riaz,et al.  Electric field enhanced 3D scalable low-voltage nano-spike electroporation system , 2017 .

[4]  Abdollah Noorbakhsh,et al.  Reduced graphene oxide-chitosan-aptamer interface as new platform for ultrasensitive detection of human epidermal growth factor receptor 2. , 2017, Biosensors & bioelectronics.

[5]  Ali Khademhosseini,et al.  Microscale electroporation: challenges and perspectives for clinical applications. , 2009, Integrative biology : quantitative biosciences from nano to macro.

[6]  Nida Nasir,et al.  Cells Electrical Characterization: Dielectric Properties, Mixture, and Modeling Theories , 2020 .

[7]  Ivar Giaever,et al.  A morphological biosensor for mammalian cells , 1993, Nature.

[8]  Min-Haw Wang,et al.  Effect of Electrode Shape on Impedance of Single HeLa Cell: A COMSOL Simulation , 2015, BioMed research international.

[9]  J. Sulé-Suso,et al.  Dielectric spectroscopy of normal and malignant human lung cells at ultra-high frequencies , 2009, Physics in medicine and biology.

[10]  Ling-Sheng Jang,et al.  Electrical characteristics analysis of various cancer cells using a microfluidic device based on single-cell impedance measurement , 2012 .

[11]  Claus Duschl,et al.  Dielectrophoretic stretching of cells allows for characterization of their mechanical properties , 2011, European Biophysics Journal.

[12]  J. Elmore,et al.  Ten-year risk of false positive screening mammograms and clinical breast examinations. , 1998, The New England journal of medicine.

[13]  T. Fujii,et al.  Development of microfluidic device for electrical/physical characterization of single cell , 2006, Journal of Microelectromechanical Systems.

[14]  Muhammad Asraf Mansor,et al.  Single Cell Electrical Characterization Techniques , 2015, International journal of molecular sciences.

[15]  E. Geiduschek,et al.  The Effect of Electrolytes on the Stability of the Deoxyribonucleate Helix , 1962 .

[16]  Yi-Kuen Lee,et al.  Using a micro electroporation chip to determine the optimal physical parameters in the uptake of biomolecules in HeLa cells. , 2007, Bioelectrochemistry.

[17]  Mae-Wan Ho,et al.  Bioenergetics and Biocommunication , 1996 .

[18]  Xiang Wang,et al.  Semiconductor Electronic Label-Free Assay for Predictive Toxicology , 2016, Scientific Reports.

[19]  Muhammad Awais Aslam,et al.  Hybrid analytical-numerical approach for investigation of differential effects in normal and cancer cells under electroporation , 2019, RSC advances.

[20]  Ling-Sheng Jang,et al.  Microfluidic device for cell capture and impedance measurement , 2007, Biomedical microdevices.

[21]  B. Riccò,et al.  Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review , 2017 .

[22]  R. Heller,et al.  Transfection by Electroporation , 2003, Current protocols in molecular biology.

[23]  Craig E. Banks,et al.  Electrochemical impedance spectroscopy: an overview of bioanalytical applications , 2013 .

[24]  Jongin Hong,et al.  Electrical cell-substrate impedance sensing as a non-invasive tool for cancer cell study. , 2011, The Analyst.

[25]  Ling-Sheng Jang,et al.  A systematic investigation into the electrical properties of single HeLa cells via impedance measurements and COMSOL simulations. , 2009, Biosensors & bioelectronics.

[26]  M. Gustafsson,et al.  Subdiffraction Multicolor Imaging of the Nuclear Periphery with 3D Structured Illumination Microscopy , 2008, Science.

[27]  C. Harris,et al.  Biomarker development in the precision medicine era: lung cancer as a case study , 2016, Nature Reviews Cancer.

[28]  Jun Li,et al.  Characterization of carbon nanofiber electrode arrays using electrochemical impedance spectroscopy: effect of scaling down electrode size. , 2010, ACS nano.

[29]  C. O. Chui,et al.  Feasibility of Tracking Multiple Single-Cell Properties with Impedance Spectroscopy. , 2018, ACS sensors.

[30]  Byungkyu Kim,et al.  Separation of malignant human breast cancer epithelial cells from healthy epithelial cells using an advanced dielectrophoresis-activated cell sorter (DACS) , 2009, Analytical and bioanalytical chemistry.

[31]  Chang Lu,et al.  Microfluidic electroporation for cellular analysis and delivery. , 2013, Lab on a chip.

[32]  R. Forbes,et al.  Some comments on models for field enhancement. , 2003, Ultramicroscopy.

[33]  R. Gatenby,et al.  Carcinogenesis and the plasma membrane. , 1999, Medical hypotheses.