Diagnostic Accuracy of an At-Home, Rapid Self-test for Influenza: Prospective Comparative Accuracy Study

Background Rapid diagnostic tests (RDTs) for influenza used by individuals at home could potentially expand access to testing and reduce the impact of influenza on health systems. Improving access to testing could lead to earlier diagnosis following symptom onset, allowing more rapid interventions for those who test positive, including behavioral changes to minimize spread. However, the accuracy of RDTs for influenza has not been determined in self-testing populations. Objective This study aims to assess the accuracy of an influenza RDT conducted at home by lay users with acute respiratory illness compared with that of a self-collected sample by the same individual mailed to a laboratory for reference testing. Methods We conducted a comparative accuracy study of an at-home influenza RDT (Ellume) in a convenience sample of individuals experiencing acute respiratory illness symptoms. Participants were enrolled in February and March 2020 from the Greater Seattle region in Washington, United States. Participants were mailed the influenza RDT and reference sample collection materials, which they completed and returned for quantitative reverse-transcription polymerase chain reaction influenza testing in a central laboratory. We explored the impact of age, influenza type, duration, and severity of symptoms on RDT accuracy and on cycle threshold for influenza virus and ribonuclease P, a marker of human DNA. Results A total of 605 participants completed all study steps and were included in our analysis, of whom 87 (14.4%) tested positive for influenza by quantitative reverse-transcription polymerase chain reaction (70/87, 80% for influenza A and 17/87, 20% for influenza B). The overall sensitivity and specificity of the RDT compared with the reference test were 61% (95% CI 50%-71%) and 95% (95% CI 93%-97%), respectively. Among individuals with symptom onset ≤72 hours, sensitivity was 63% (95% CI 48%-76%) and specificity was 94% (95% CI 91%-97%), whereas, for those with duration >72 hours, sensitivity and specificity were 58% (95% CI 41%-74%) and 96% (95% CI 93%-98%), respectively. Viral load on reference swabs was negatively correlated with symptom onset, and quantities of the endogenous marker gene ribonuclease P did not differ among reference standard positive and negative groups, age groups, or influenza subtypes. The RDT did not have higher sensitivity or specificity among those who reported more severe illnesses. Conclusions The sensitivity and specificity of the self-test were comparable with those of influenza RDTs used in clinical settings. False-negative self-test results were more common when the test was used after 72 hours of symptom onset but were not related to inadequate swab collection or severity of illness. Therefore, the deployment of home tests may provide a valuable tool to support the management of influenza and other respiratory infections.

[1]  J. Brownstein,et al.  Evaluating an app-guided self-test for influenza: lessons learned for improving the feasibility of study designs to evaluate self-tests for respiratory viruses , 2021, BMC Infectious Diseases.

[2]  J. Hughes,et al.  Seroprevalence of SARS-CoV-2 antibodies in Seattle, Washington: October 2019–April 2020 , 2020, medRxiv.

[3]  M. Rieder,et al.  The Seattle Flu Study: a multiarm community-based prospective study protocol for assessing influenza prevalence, transmission and genomic epidemiology , 2020, BMJ Open.

[4]  Tim Althoff,et al.  Measuring COVID-19 and Influenza in the Real World via Person-Generated Health Data , 2020, medRxiv.

[5]  A. Perosa,et al.  Influenza A(H1N1)pdm09 infection and viral load analysis in patients with different clinical presentations , 2020, Memorias do Instituto Oswaldo Cruz.

[6]  J. Wong,et al.  Nonpharmaceutical Measures for Pandemic Influenza in Nonhealthcare Settings—Social Distancing Measures , 2020, Emerging infectious diseases.

[7]  B. Cowling,et al.  Self-collected compared with professional-collected swabbing in the diagnosis of influenza in symptomatic individuals: A meta-analysis and assessment of validity. , 2019, Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology.

[8]  J. Gooding,et al.  Systematic review of the impact of point‐of‐care testing for influenza on the outcomes of patients with acute respiratory tract infection , 2018, Reviews in medical virology.

[9]  D. Green,et al.  Rapid Antigen Tests for Influenza: Rationale and Significance of the FDA Reclassification , 2018, Journal of Clinical Microbiology.

[10]  M. Stockwell,et al.  Economic burden of seasonal influenza in the United States. , 2018, Vaccine.

[11]  D. Dwyer,et al.  Point-of-care diagnostics for respiratory viral infections , 2017, Expert review of molecular diagnostics.

[12]  G. Gore,et al.  Diagnostic Accuracy of Novel and Traditional Rapid Tests for Influenza Infection Compared With Reverse Transcriptase Polymerase Chain Reaction , 2017, Annals of Internal Medicine.

[13]  D. Pajkrt,et al.  Rapid Tests for Influenza, Respiratory Syncytial Virus, and Other Respiratory Viruses: A Systematic Review and Meta-analysis , 2017, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[14]  Self-tests for influenza: an empirical ethics investigation , 2017, BMC medical ethics.

[15]  M. Biggerstaff,et al.  Community Mitigation Guidelines to Prevent Pandemic Influenza — United States, 2017 , 2017, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[16]  Johannes B Reitsma,et al.  STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration , 2016, BMJ Open.

[17]  John H. Powers,et al.  Development of the Flu-PRO: a patient-reported outcome (PRO) instrument to evaluate symptoms of influenza , 2015, BMC Infectious Diseases.

[18]  Rumi Chunara,et al.  Flu Near You: Crowdsourced Symptom Reporting Spanning 2 Influenza Seasons. , 2015, American journal of public health.

[19]  D. David,et al.  Results of a pilot study using self-collected mid-turbinate nasal swabs for detection of influenza virus infection among pregnant women , 2015, Influenza and other respiratory viruses.

[20]  D. Fleming,et al.  Self-sampling for community respiratory illness: a new tool for national virological surveillance. , 2015, Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin.

[21]  M. Van Ranst,et al.  Sampling variability between two mid-turbinate swabs of the same patient has implications for influenza viral load monitoring , 2014, Virology Journal.

[22]  J. Morris,et al.  High percentage of false-positive results for influenza B obtained with a rapid influenza point-of-care test. , 2014, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[23]  T. Naito,et al.  Factors influencing the diagnostic accuracy of the rapid influenza antigen detection test (RIADT): a cross-sectional study , 2014, BMJ Open.

[24]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[25]  T. Leung,et al.  Clinical and Virologic Factors Associated with Reduced Sensitivity of Rapid Influenza Diagnostic Tests in Hospitalized Elderly Patients and Young Children , 2013, Journal of Clinical Microbiology.

[26]  Johannes B Reitsma,et al.  Variation of a test’s sensitivity and specificity with disease prevalence , 2013, Canadian Medical Association Journal.

[27]  J. Oxford,et al.  Comparing Influenza and Rsv Viral and Disease Dynamics in Experimentally Infected Adults Predicts Clinical Effectiveness of Rsv Antivirals , 2013, Antiviral therapy.

[28]  B. Nivin,et al.  Cluster of False-Positive Influenza B Virus Rapid Antigen Test Results in a New York City Hospital , 2012, Journal of Clinical Microbiology.

[29]  T. West,et al.  Faculty Opinions recommendation of Accuracy of rapid influenza diagnostic tests: a meta-analysis. , 2012 .

[30]  Ralph Gonzales,et al.  Development and Validation of a Clinical Decision Rule for the Diagnosis of Influenza , 2012, The Journal of the American Board of Family Medicine.

[31]  Benjamin J Cowling,et al.  Viral Shedding and Clinical Illness in Naturally Acquired Influenza Virus Infections , 2010, The Journal of infectious diseases.

[32]  B. Cowling,et al.  Factors affecting QuickVue Influenza A + B rapid test performance in the community setting. , 2009, Diagnostic microbiology and infectious disease.

[33]  E. Wilander,et al.  Self-sampling of the vaginal fluid at home combined with high-risk HPV testing , 2009, British Journal of Cancer.

[34]  J. Sung,et al.  Viral Loads and Duration of Viral Shedding in Adult Patients Hospitalized with Influenza , 2009, The Journal of infectious diseases.

[35]  P. Harris,et al.  Research electronic data capture (REDCap) - A metadata-driven methodology and workflow process for providing translational research informatics support , 2009, J. Biomed. Informatics.

[36]  William Schaffner,et al.  Accuracy and Interpretation of Rapid Influenza Tests in Children , 2007, Pediatrics.

[37]  Yi Guan,et al.  Fatal outcome of human influenza A (H5N1) is associated with high viral load and hypercytokinemia , 2006, Nature Medicine.