Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty

Background and purpose — While highly crosslinked polyethylene has shown reduced in vivo wear and lower rates of revision for total hip arthroplasty, there have been few long-term studies on its use in total knee arthroplasty (TKA). We compared the rate of revision of non-crosslinked polyethylene to that of crosslinked polyethylene in patients who underwent TKA for osteoarthritis. Patients and methods — We examined data from the Australian Orthopaedic Association National Joint Replacement Registry on 302,214 primary TKA procedures with non-crosslinked polyethylene and 83,890 procedures with crosslinked polyethylene, all of which were performed for osteoarthritis. The survivorship of the different polyethylenes was estimated using the Kaplan-Meier method and was compared using proportional hazard models. Results — The 10-year cumulative revision rate for non-crosslinked polyethylene was 5.8% (95% CI: 5.7–6.0) and for crosslinked polyethylene it was 3.5% (95% CI: 3.2–3.8) (> 6.5-year HR = 2.2 (1.5–3.1); p < 0.001). There was no effect of surgical volume or method of prosthesis fixation on outcome. There were 4 different TKA designs that had a minimum of 2,500 procedures in at least 1 of the polyethylene groups and a follow-up of ≥ 5 years. 2 of these, the NexGen and the Natural Knee II, had a lower rate of revision for crosslinked polyethylene. The Scorpio NRG/Series 7000 and the Triathlon Knee did not show a lower rate of revision for crosslinked polyethylene. Interpretation — There is a lower rate of revision for crosslinked polyethylene in TKA, and this appears to be prosthesis-specific and when it occurs is most evident in patients < 65 years of age. The difference in revision rates was mainly due to revisions because of lysis and loosening.

[1]  Theodore S. Wolfson,et al.  10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty. , 2014, The Journal of arthroplasty.

[2]  R. Trousdale,et al.  Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up. , 2013, The Journal of arthroplasty.

[3]  G. Scuderi**,et al.  Highly cross-linked polyethylene in posterior stabilized total knee arthroplasty: early results. , 2012, The Orthopedic clinics of North America.

[4]  Shin-Yoon Kim,et al.  Midterm results of primary total hip arthroplasty using highly cross-linked polyethylene: minimum 7-year follow-up study. , 2011, The Journal of arthroplasty.

[5]  H. Gill,et al.  The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. , 2011, The Journal of bone and joint surgery. American volume.

[6]  Y. Minoda,et al.  Comparison between highly cross-linked and conventional polyethylene in total knee arthroplasty. , 2009, The Knee.

[7]  D. D’Lima,et al.  The effect of oxidative aging on the wear performance of highly crosslinked polyethylene knee inserts under conditions of severe malalignment , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  A. Hofmann,et al.  Highly Crosslinked Polyethylene is Safe for Use in Total Knee Arthroplasty , 2008, Clinical orthopaedics and related research.

[9]  I. Clarke,et al.  Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[10]  I. Clarke,et al.  Wear and toughness of crosslinked polyethylene for total knee replacements: A study using a simulator and small‐punch testing , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  W. Harris,et al.  Knee Simulator Wear of Polyethylene Tibias Articulating against Explanted Rough Femoral Components , 2004, Clinical orthopaedics and related research.

[12]  W. Harris,et al.  Aggressive Wear Testing of a Cross-Linked Polyethylene in Total Knee Arthroplasty , 2002, Clinical orthopaedics and related research.