Analytical variability in sport hematology: its importance in an antidoping setting

Abstract Hematologic parameters are commonly utilized in sports medicine and antidoping testing. However, there are no universally accepted methodologies for comparing the performance of automated blood analyzer systems. To address this problem, we selected and examined 19 studies from a review of literature published from 2000 to 2010. Meaningful discrepancies were found between measurements obtained with different analytical systems. Because harmonization and clear standardization of methods are lacking, the analytical variability often largely exceeds intra- and inter-individual biological differences, producing equivocal test results unreliable for clinical and antidoping testing. A central criticality to applying the Bayesian approach is analytical variability, but the use of different analytical technologies precludes the comparison of inter-methods for determining the robustness of blood variables and their clinical significance. Therefore, future multicenter studies are needed to compare analytical methodologies and blood analyzer systems, and to establish worldwide-accepted standards and quality control protocols.

[1]  G. Lippi,et al.  Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer. , 2005, The Journal of laboratory and clinical medicine.

[2]  G. Lippi,et al.  Comments on Delanghe and Joyner's editorial "testing for recombinant human erythropoietin". Preanalytical and analytical issues in indirect hematological testing. , 2008, Journal of applied physiology.

[3]  Kerry R Emslie,et al.  Development of reference ranges in elite athletes for markers of altered erythropoiesis. , 2002, Haematologica.

[4]  Ulrich Flenker,et al.  Stability tests for hematological parameters in antidoping analyses. , 2008, Laboratory hematology : official publication of the International Society for Laboratory Hematology.

[5]  Martial Saugy,et al.  A forensic approach to the interpretation of blood doping markers , 2008 .

[6]  Ken Sharpe,et al.  A third generation approach to detect erythropoietin abuse in athletes. , 2006, Haematologica.

[7]  M. Siloaho,et al.  Pre‐analytical factors and measurement uncertainty , 2005, Scandinavian journal of clinical and laboratory investigation.

[8]  C J Gore,et al.  A novel method utilising markers of altered erythropoiesis for the detection of recombinant human erythropoietin abuse in athletes. , 2000, Haematologica.

[9]  J. Mørkeberg,et al.  Changes in Blood Values in Elite Cyclist , 2008, International journal of sports medicine.

[10]  M. Saugy,et al.  Stability and robustness of blood variables in an antidoping context , 2011, International journal of laboratory hematology.

[11]  M. Dopsaj,et al.  Haematological and iron-related parameters in male and female athletes according to different metabolic energy demands , 2011, European Journal of Applied Physiology.

[12]  G. Banfi,et al.  The values of immature reticulocytes fraction in élite athletes measured by means of two different technologies are concordant. , 2006, The Journal of sports medicine and physical fitness.

[13]  Ken Sharpe,et al.  Standardization of reticulocyte values in an antidoping context. , 2004, American journal of clinical pathology.

[14]  G. Banfi Reticulocytes in Sports Medicine , 2008, Sports medicine.

[15]  G. Banfi How are antidoping laboratories controlled? , 2010 .

[16]  Martial Saugy,et al.  Bayesian detection of abnormal hematological values to introduce a no-start rule for heterogeneous populations of athletes. , 2007, Haematologica.

[17]  S. Lewis,et al.  International Council for Standardization in Haematology – the first 40 years , 2009, International journal of laboratory hematology.

[18]  P. Rizzotti,et al.  Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analyzers: an NCCLS-ICSH approach. , 2001, American journal of clinical pathology.

[19]  H. Neels,et al.  Reference Intervals for a Complete Blood Count Determined on different Automated Haematology Analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120 , 2002, Clinical chemistry and laboratory medicine.

[20]  M. Audran,et al.  Longitudinal variation of hemoglobin and reticulocytes in elite rowers. , 2004, Haematologica.

[21]  G. Banfi,et al.  Comparison of 3 automatic systems for reticulocytes counts during an ultraendurance mountain marathon. , 2003, The Journal of sports medicine and physical fitness.

[22]  N Robinson,et al.  Haematological analysis conducted at the departure of the Tour de France 2001. , 2005, International journal of sports medicine.

[23]  C. Lundby,et al.  Seasonal variations of haematological parameters in athletes , 2010, European Journal of Applied Physiology.

[24]  Martial Saugy,et al.  Time and temperature dependant changes in red blood cell analytes used for testing recombinant erythropoietin abuse in sports. , 2004, Clinical laboratory.