Development of new and validation of existing convection correlations for rooms with displacement ventilation systems

Building airflow, thermal, and contaminant simulation programs need accurate models for the surface convective boundary conditions. This is, especially, the case for displacement ventilation (DV) systems, where convective buoyancy forces at room surfaces significantly affect the airflow pattern and temperature and contaminant distributions. Nevertheless, for DV, as a relatively new ventilation system, the convective correlations are adopted from more traditional mixing ventilation correlations, or non-existent. In this study, the existing recommended correlations are validated in a full-scale experimental facility representing an office space. In addition, new correlations are developed for floor surfaces because the current literature does not provide necessary correlations, even though, the floor surface is responsible for >50% of the total convective heat transfer at the envelope. The convective correlations are typically functions of a surface-air temperature difference, airflow parameters, and characteristic room dimensions. Validation results show that the floor convection correlations expressed as a function of volume flow rate are much stronger than the correlations expressed as a function of a temperature difference between the surface and local air. Consequently, the new convection correlation for floor surfaces is a function of the number of hourly room air changes (ACH). This correlation also takes into account buoyant effects from local floor heat patches. Experimental data show that the existing correlation can be successfully applied to vertical and ceiling surfaces in spaces with DV diffuser(s). Overall, the new and the existing convection correlations are tabulated for use in building simulation programs, such as annual energy analyses or computational fluid dynamics.

[1]  Atila Novoselac,et al.  Combined Airflow and Energy Simulation Program for Building Mechanical System Design , 2004 .

[2]  Stuart W. Churchill,et al.  A general expression for the correlation of rates of transfer and other phenomena , 1972 .

[3]  Daniel E. Fisher,et al.  Convective heat transfer in building energy and thermal load calculations , 1997 .

[4]  Ian Beausoleil-Morrison,et al.  The adaptive coupling of heat and air flow modelling within dynamic whole-building simulation , 2000 .

[5]  J. M. Coulson,et al.  Heat Transfer , 2018, Heat Transfer in Food Cooling Applications.

[6]  Daniel E. Fisher,et al.  An experimental investigation of mixed convection heat transfer in a rectangular enclosure , 1995 .

[7]  Hazim B. Awbi,et al.  Mixed convection from heated room surfaces , 2000 .

[8]  Van P. Carey,et al.  An Experimental Study of High Rayleigh Number Mixed Convection in a Rectangular Enclosure With Restricted Inlet and Outlet Openings , 1987 .

[9]  J. Spurk Boundary Layer Theory , 2019, Fluid Mechanics.

[10]  H. Awbi,et al.  Natural convection from heated room surfaces , 1999 .

[11]  R. H. Marshall,et al.  Validation of heat transfer coefficients on interior building surfaces using a real-sized indoor test cell , 1990 .

[12]  Geoffrey P. Hammond,et al.  Improved data correlations for buoyancy-driven convection in rooms , 1983 .

[13]  M. J. Wheeler Heat and Mass Transfer , 1968, Nature.

[14]  Philip Haves,et al.  A nodal model for displacement ventilation and chilled ceiling systems in office spaces , 2001 .