Magnetoacoustic tomography with current injection

Magnetoacoustic tomography combines the advantages of electrical impedance tomography with sonography. It can reconstruct conductivity images of biological tissue with high spatial resolution and high contrast. In addition, magnetoacoustic tomography is a new nondestructive functional imaging technology, with which we can realize the early diagnosis of human diseases. In this paper, through theory analysis we deduced the analytical formula of acoustic pressure. Computer simulation and experimental studies on magnetoacoustic tomography with current injection (MAT-CI) were made, and a copper ring was used as the model for the simulation and experiment. Experimental setup and methods are introduced, and the acoustic signals and the image of a metal object by means of MAT-CI are presented. Results of the simulation and experiment were in a good agreement. The reconstructed image of an acoustic source can reflect the conductivity information of a sample. The conductivity distribution of a sample can be obtained by means of MAT-CI. The results provide foundations of study on a model with complex conductivity distribution and tissues for MAT-CI.

[1]  Bin He,et al.  Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction. , 2007, Applied physics letters.

[2]  Zhang Shun Study on Imaging with Current Exciting Conductivity Model Based on Magnetoacoustic Effect , 2011 .

[3]  Ma Qing-yu,et al.  Two-Dimensional Lorentz Force Image Reconstruction for Magnetoacoustic Tomography with Magnetic Induction , 2010 .

[4]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[5]  Bruno De Man,et al.  An outlook on x-ray CT research and development. , 2008, Medical physics.

[6]  B. He High-resolution Functional Source and Impedance Imaging , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[7]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) , 2005, Physics in medicine and biology.

[8]  Bin He,et al.  Magnetoacoustic Imaging of Electrical Conductivity of Biological Tissues at a Spatial Resolution Better than 2 mm , 2011, PloS one.

[9]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction for imaging electrical impedance of biological tissue , 2006 .

[10]  Jian Yu,et al.  A novel prosody adaptation method for Mandarin concatenation-based text-to-speech system , 2009 .

[11]  Xu Li,et al.  Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI) , 2007, IEEE Transactions on Biomedical Engineering.

[12]  Lihong V. Wang,et al.  Time reversal and its application to tomography with diffracting sources. , 2004, Physical review letters.

[13]  Wang Yuan-yuan Simulation study of medical ultrasound imaging , 2011 .

[14]  Martin Kuiper,et al.  Specific Impact of Tobamovirus Infection on the Arabidopsis Small RNA Profile , 2011, PloS one.

[15]  Bin He,et al.  Magnetoacoustic tomography with magnetic induction (MAT-MI) for electrical conductivity imaging , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Kevin Paulson,et al.  Optimal experiments in electrical impedance tomography , 1993, IEEE Trans. Medical Imaging.