Poly-vinyl alcohol hydrogel vascular models for in vitro aneurysm simulations: the key to low friction surfaces.

PURPOSE To develop a vessel model with poly-vinyl alcohol hydrogel (PVA-H) with low surface friction for in vitro simulations of vascular pathologies. MATERIALS AND METHODS Simulations of variable vascular pathologies were based on human vessel casts reproduced in wax. Constructions of vascular models were then obtained by lost wax techniques. As materials, liquid silicon or PVA in organic solvents were used. After solidification, the wax was drained by heating. Comparison of PVA-H with silicone models included evaluation of surface characteristics (friction coefficient), of visibility (transparence and compatibility with medical imaging techniques), and of stiffness (pulsatility of vascular lumen). Both model types were integrated in a circulation circuit allowing for flow simulations and testing with endovascular medical devices. RESULTS AND CONCLUSION Both model types were transparent and compatible with current medical imaging methods. PVA-H models exhibited much lower friction characteristics. PVA-H stiffness was closer to soft tissue when compared to silicone, allowing for pulsations during flow simulations.

[1]  A. G. Gibson,et al.  Dynamic mechanical behaviour and longitudinal crystal thickness measurements on ultra-high modulus linear polyethylene: a quantitative model for the elastic modulus , 1978 .

[2]  Daniel A. Rüfenacht,et al.  Anin vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms , 1997 .

[3]  David M. Williams,et al.  Endovascular treatment of aortic aneurysms in patients with renal transplants. , 2003, Journal of vascular surgery.

[4]  D J Valentino,et al.  Automatic skeleton generation for visualizing 3D, time-dependent fluid flows: application to the virtual aneurysm. , 2001, Studies in health technology and informatics.

[5]  H. van Loveren,et al.  Colored silicone injection for use in neurosurgical dissections: anatomic technical note. , 1999, Neurosurgery.

[6]  K W Dalgarno,et al.  Flexible tubular replicas of abdominal aortic aneurysms , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[7]  A. G. Gibson,et al.  Shear and tensile relaxation behaviour in oriented linear polyethylene , 1982 .

[8]  C W Kerber,et al.  Transparent elastic arterial models. I: A brief technical note. , 1989, Biorheology.

[9]  C W Kerber,et al.  Arteriovenous malformation model for training and research. , 1997, AJNR. American journal of neuroradiology.

[10]  C. R. Ethier,et al.  Flow waveform effects on end-to-side anastomotic flow patterns. , 1998, Journal of biomechanics.

[11]  P. Gailloud,et al.  Artificial cerebral aneurysm model for medical testing, training, and research. , 2003, Neurologia medico-chirurgica.