Control of intravascular catheters using an array of active steering coils.

PURPOSE To extend the concept of deflecting the tip of a catheter with the magnetic force created in an MRI system through the use of an array of independently controllable steering coils located in the catheter tip, and to present methods for visualization of the catheter and/or surrounding areas while the catheter is deflected. METHODS An array of steering coils made of 42-gauge wire was built over a 2.5 Fr (0.83 mm) fiber braided microcatheter. Two of the coils were 70 turn axial coils separated by 1 cm, and the third was a 15-turn square side coil that was 2 x 4 mm2. Each coil was driven independently by a pulse width modulation (PWM) current source controlled by a microprocessor that received commands from a MATLAB routine that dynamically set current amplitude and direction for each coil. The catheter was immersed in a water phantom containing 1% Gd-DTPA that was placed at the isocenter of a 1.5 T MRI scanner. Deflections of the catheter tip were measured from image-based data obtained with a real-time radio frequency (RF) spoiled gradient echo sequence (GRE). The small local magnetic fields generated by the steering coils were exploited to generate a hyperintense signal at the catheter tip by using a modified GRE sequence that did not include slice-select rewinding gradients. Imaging and excitation modes were implemented by synchronizing the excitation of the steering coil array with the scanner by ensuring that no current was driven through the coils during the data acquisition window; this allowed visualization of the surrounding tissue while not affecting the desired catheter position. RESULTS Deflections as large as 2.5 cm were measured when exciting the steering coils sequentially with a 100 mA maximum current per coil. When exciting a single axial coil, the deflection was half this value with 30% higher current. A hyperintense catheter tip useful for catheter tracking was obtained by imaging with the modified GRE sequence. Clear visualization of the areas surrounding the catheter was obtained by using the excitation and imaging mode even with a repetition time (TR) as small as 10 ms. CONCLUSIONS A new system for catheter steering is presented that allows large deflections through the use of an integrated array of steering coils. Additionally, two imaging techniques for tracking the catheter tip and visualization of surrounding areas, without interference from the active catheter, were shown. Together the demonstrated steerable catheter, control system and the imaging techniques will ultimately contribute to the development of a steerable system for interventional MRI procedures.

[1]  K. E. Bisshopp,et al.  Large deflection of cantilever beams , 1945 .

[2]  James C.H. Chu,et al.  Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures , 2005, Journal of applied clinical medical physics.

[3]  C J Bakker,et al.  Development of an MR‐safe tracking catheter with a laser‐driven tip coil , 2001, Journal of magnetic resonance imaging : JMRI.

[4]  I. Tunay,et al.  Modeling magnetic catheters in external fields , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  C. Neipp,et al.  Numerical and Experimental Analysis of Large Deflections of Cantilever Beams Under a Combined Load , 2005 .

[6]  M A Howard,et al.  Preliminary experimental investigation of in vivo magnetic manipulation: results and potential application in hyperthermia. , 1989, Medical physics.

[7]  R L Arenson,et al.  Remote control of catheter tip deflection: An opportunity for interventional MRI , 2002, Magnetic resonance in medicine.

[8]  M A Viergever,et al.  Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventions , 1996, Magnetic resonance in medicine.

[9]  Michael O Zenge,et al.  Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization , 2005, Magnetic resonance in medicine.

[10]  M. L. Lauzon,et al.  Passive catheter visualization in magnetic resonance–guided endovascular therapy using multicycle projection dephasers , 2006, Journal of magnetic resonance imaging : JMRI.

[11]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.

[12]  J. Debatin,et al.  Active MR visualization of a vascular guidewire in vivo , 1998, Journal of magnetic resonance imaging : JMRI.

[13]  Wolfhard Semmler,et al.  MR‐guided intravascular procedures: Real‐time parameter control and automated slice positioning with active tracking coils , 2004, Journal of magnetic resonance imaging : JMRI.

[14]  M. Ladd,et al.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes , 2000, Magnetic Resonance in Medicine.

[15]  J S Lewin,et al.  Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 T , 1998, Journal of magnetic resonance imaging : JMRI.

[16]  Gabriel Acevedo-Bolton,et al.  MR imaging during endovascular procedures: An evaluation of the potential for catheter heating , 2009, Magnetic resonance in medicine.

[17]  R. C. Susil,et al.  RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field , 2002, Magnetic resonance in medicine.

[18]  Jeffrey L Duerk,et al.  A review of technical advances in interventional magnetic resonance imaging. , 2005, Academic radiology.

[19]  Tobias G. Noll,et al.  Device visualization for interventional MRI using local magnetic fields: basic theory and its application to catheter visualization , 1998, IEEE Transactions on Medical Imaging.

[20]  Sylvain Martel,et al.  Magnetic Steering of Iron Oxide Microparticles Using Propulsion Gradient Coils in MRI , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Mark Wilson,et al.  Magnetically-assisted remote control (MARC) steering of endovascular catheters for interventional MRI: A model for deflection and design implications. , 2007, Medical physics.