role of chlorine and chloramine in corrosion of lead‐bearing plumbing materials

A switch from free chlorine to chloramine disinfectant triggered problems with excessive lead in Washington, D.C., drinking water. High levels of lead originated in the service lines, but excessive lead was also derived from solder or brass plumbing materials. In many cases, the highest lead concentrations emerged from the tap after about 1 min of flushing-a troublesome outcome, given that routine public notification recommended that consumers flush for about a minute to minimize lead exposure. Bench-scale testing found that chlorine reacts with soluble Pb +2 to rapidly precipitate a red-brown-colored lead solid that was insoluble even at pH 1.9 for 12 weeks; this solid did not form in the presence of chloramine. Further experiments indicated that chloramines sometimes dramatically worsened lead leaching from brass relative to free chlorine, whereas new lead pipe was not strongly affected.

[1]  Michael Schock,et al.  Plumbosolvency reduction by high pH and low carbonate- solubility relationships , 1983 .

[2]  Werner Troesken,et al.  Lead Water Pipes and Infant Mortality in Turn-of-The-Century Massachusetts , 2003 .

[3]  Thurston Eric Larson,et al.  Corrosion of brass by chloramine , 1956 .

[4]  A. Okuwaki,et al.  The dissolution behavior of lead plates in aqueous nitrate solutions , 1999 .

[5]  M. Edwards,et al.  Effect of aluminium solids and chlorine on cold water pitting of copper , 2004 .

[6]  J. Graef,et al.  Lead Intoxication , 1989, Clinical pediatrics.

[7]  J. Ayuso-Mateos,et al.  Estimating the global burden of disease of mild mental retardation and cardiovascular diseases from environmental lead exposure. , 2004, Environmental research.

[8]  K. Weizsaecker Lead toxicity during pregnancy , 2003 .

[9]  P. Westerhoff Reduction of Nitrate, Bromate, and Chlorate by Zero Valent Iron (Fe0) , 2003 .

[10]  S. S. A. Rehim,et al.  Passivity breakdown of lead anode in alkaline nitrate solutions , 1998 .

[11]  R. Renner Plumbing the depths of D.C.'s drinking water crisis. , 2004, Environmental science & technology.

[12]  Laurie S. McNeill,et al.  Determination of total chromium in environmental water samples. , 2004, Water research.

[13]  V. Snoeyink,et al.  Effect of ortho‐and polyphosphates on the properties of IRON PARTICLES AND SUSPENSIONS , 2002 .

[14]  Michael R. Schock,et al.  Understanding Corrosion Control Strategies for Lead , 1989 .

[15]  R. Fertmann,et al.  Lead exposure by drinking water: an epidemiologial study in Hamburg, Germany. , 2004, International journal of hygiene and environmental health.

[16]  C. Waternaux,et al.  Low-level lead exposure and children's cognitive function in the preschool years. , 1991, Pediatrics.

[17]  L. Hermer-Vazquez,et al.  Enduring effects of early lead exposure: evidence for a specific deficit in associative ability. , 2000, Neurotoxicology and teratology.

[18]  A. Okuwaki,et al.  Decomposition of nitrate by in situ buff abrasion of lead plate , 1998 .