Pentacene Coated Atop of Ultrathin InN Gas Sensor Device for the Selective Sensing of Ammonia Gas for Liver Malfunction Application
暂无分享,去创建一个
[1] J. Andrew Yeh,et al. A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs , 2012, Sensors.
[2] Enrico Traversa,et al. Ceramic sensors for humidity detection: the state-of-the-art and future developments , 1995 .
[3] Chuji Wang,et al. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits , 2009, Sensors.
[4] D. K. Aswal,et al. Simple and low-temperature polyaniline-based flexible ammonia sensor: a step towards laboratory synthesis to economical device design , 2015 .
[5] I. Hirata,et al. Breath and blood ammonia in liver cirrhosis. , 2000, Hepato-gastroenterology.
[6] Chao Jiang,et al. Novel top-contact monolayer pentacene-based thin-film transistor for ammonia gas detection. , 2014, ACS applied materials & interfaces.
[7] Ulrike Tisch,et al. Monolayer-Capped Cubic Platinum Nanoparticles for Sensing Nonpolar Analytes in Highly Humid Atmospheres , 2010 .
[8] Quanfang Chen,et al. Micromachined nanocrystalline silver doped SnO2 H2S sensor , 2006 .
[9] J. Câmara,et al. Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview , 2015, Metabolites.
[10] Junhong Chen,et al. Controllable synthesis of silver nanoparticle-decorated reduced graphene oxide hybrids for ammonia detection. , 2013, The Analyst.
[11] Dong Xiang,et al. Metal Oxide Gas Sensors: Sensitivity and Influencing Factors , 2010, Sensors.
[12] Christophe Pijolat,et al. Application of membranes and filtering films for gas sensors improvements , 2005 .
[13] Joachim Goschnick,et al. A gradient microarray electronic nose based on percolating SnO(2) nanowire sensing elements. , 2007, Nano letters.
[14] Himadri Sekhar Maiti,et al. Selective detection of methane and butane by temperature modulation in iron doped tin oxide sensors , 2006 .
[15] T. Jackson,et al. Stacked pentacene layer organic thin-film transistors with improved characteristics , 1997, IEEE Electron Device Letters.
[16] E. McCafferty,et al. Adsorption of water vapour on α-Fe2O3 , 1971 .
[17] Jian Song,et al. Preparation and Gas Sensing Properties of In2O3/Au Nanorods for Detection of Volatile Organic Compounds in Exhaled Breath , 2015, Scientific Reports.
[18] Udo Weimar,et al. Gas identification by modulating temperatures of SnO2-based thick film sensors , 1997 .
[19] Giovanni Neri,et al. First Fifty Years of Chemoresistive Gas Sensors , 2015 .
[20] Rafiq Ahmad,et al. Chemical and biological sensors based on metal oxide nanostructures. , 2012, Chemical communications.
[21] Q. Zhang,et al. Diagnosis of diabetes by image detection of breath using gas-sensitive LAPS. , 2000, Biosensors & bioelectronics.
[22] F. Yu,et al. Uptake of neutral polar vapor molecules by charged clusters/particles: Enhancement due to dipole‐charge interaction , 2003 .
[23] Anthony J. Killard,et al. Breath Ammonia Analysis: Clinical Application and Measurement , 2011 .
[24] N. Bârsan,et al. Electronic nose: current status and future trends. , 2008, Chemical reviews.
[25] L. Zieve,et al. Volatile fatty acids in the breath of patients with cirrhosis of the liver. , 1970, The Journal of laboratory and clinical medicine.
[26] R. Cavicchi,et al. Optimization of temperature programmed sensing for gas identification using micro-hotplate sensors , 1998 .
[27] B. Reedy,et al. Temperature modulation in semiconductor gas sensing , 1999 .
[28] E. Martinelli,et al. Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors. , 2003, Biosensors & bioelectronics.
[29] Distinction of gases with a semiconductor sensor depending on the scanning profile of a cyclic temperature. , 2006, The Analyst.
[30] Udo Weimar,et al. STRATEGIES TO AVOID VOC CROSS-SENSITIVITY OF SNO2-BASED CO SENSORS , 1999 .
[31] Hsiao-Wen Zan,et al. Pentacene-Based Organic Thin Film Transistors for Ammonia Sensing , 2012, IEEE Sensors Journal.
[32] Katrin Schmitt,et al. Towards Enhanced Gas Sensor Performance with Fluoropolymer Membranes , 2016, Sensors.
[33] Sumita Santra,et al. Hierarchical nanostructured WO3-SnO2 for selective sensing of volatile organic compounds. , 2015, Nanoscale.
[34] Célia Lourenço,et al. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications , 2014, Metabolites.
[35] J. Yeh,et al. Highly Sensitive Hydrogen Detection Using a Pt-Catalyzed InN Epilayer , 2010 .
[36] Lester F. Eastman,et al. Surface charge accumulation of InN films grown by molecular-beam epitaxy , 2003 .
[37] Geraint Williams,et al. Selectivity studies on tin oxide-based semiconductor gas sensors , 1991 .
[38] Joan M. Redwing,et al. X-ray photoemission spectroscopic investigation of surface treatments, metal deposition, and electron accumulation on InN , 2003 .
[39] Anton Amann,et al. Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors , 2015 .
[40] Xuejun Zheng,et al. Electrical response of Sm2O3-doped SnO2 to C2H2 and effect of humidity interference , 2008 .
[41] W. Schaff,et al. Intrinsic electron accumulation at clean InN surfaces. , 2004, Physical review letters.
[42] S. Kulkarni,et al. Ultrasensitive Gold Nanostar-Polyaniline Composite for Ammonia Gas Sensing. , 2015, Langmuir : the ACS journal of surfaces and colloids.
[43] A. Manolis,et al. The diagnostic potential of breath analysis. , 1983, Clinical chemistry.
[44] J. Andrew Yeh,et al. Anion detection using ultrathin InN ion selective field effect transistors , 2008 .
[45] Ji Haeng Yu,et al. Selective CO gas detection of CuO- and ZnO-doped SnO2 gas sensor , 2001 .
[46] W. Schaff,et al. Indium nitride: Evidence of electron accumulation , 2004 .
[47] J. Geoffrey Chase,et al. Classifying algorithms for SIFT-MS technology and medical diagnosis , 2008, Comput. Methods Programs Biomed..
[48] Friedhelm Bechstedt,et al. Origin of electron accumulation at wurtzite InN surfaces , 2004 .
[49] Akio Yamamoto,et al. Indium nitride (InN): A review on growth, characterization, and properties , 2003 .
[50] T. Pustelny,et al. Effect of Humidity on Nh3 Gas Sensitivity of Nafion R /WO3 Sensing Structure of Spr Sensor , 2005 .
[51] J. Andrew Yeh,et al. InN-based anion selective sensors in aqueous solutions , 2007 .
[52] S. Tjoa,et al. The identification of trimethylamine excess in man: quantitative analysis and biochemical origins. , 1991, Analytical biochemistry.
[53] Alexander Star,et al. Gas sensor array based on metal-decorated carbon nanotubes. , 2006, The journal of physical chemistry. B.
[54] Karl Crowley,et al. Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors. , 2013, Analytical chemistry.
[55] P. Chaparala,et al. Fast temperature programmed sensing for micro-hotplate gas sensors , 1995, IEEE Electron Device Letters.