Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers

Results from both experimental measurements and 3D numerical simulations of Ground Source Heat Pump systems (GSHP) at a UK climate are presented. Experimental measurements of a horizontal-coupled slinky GSHP were undertaken in Talbot Cottage at Drayton St Leonard site, Oxfordshire, UK. The measured thermophysical properties of in situ soil were used in the CFD model. The thermal performance of slinky heat exchangers for the horizontal-coupled GSHP system for different coil diameters and slinky interval distances was investigated using a validated 3D model. Results from a two month period of monitoring the performance of the GSHP system showed that the COP decreased with the running time. The average COP of the horizontal-coupled GSHP was 2.5. The numerical prediction showed that there was no significant difference in the specific heat extraction of the slinky heat exchanger at different coil diameters. However, the larger the diameter of coil, the higher the heat extraction per meter length of soil. The specific heat extraction also increased, but the heat extraction per meter length of soil decreased with the increase of coil central interval distance.

[1]  P. D. Metz Ground-coupled heat pump system experimental results , 1983 .

[2]  Georgios A. Florides,et al.  Ground heat exchangers—A review of systems, models and applications , 2007 .

[3]  Salih Coskun,et al.  Experimental performance investigation of a horizontal ground source compression refrigeration machine , 2008 .

[4]  Mustafa Inalli,et al.  Experimental thermal performance evaluation of a horizontal ground-source heat pump system , 2004 .

[5]  M. Piechowski,et al.  Heat and mass transfer model of a Ground Heat Exchanger: theoretical development , 1999 .

[6]  P. Eames,et al.  Factors influencing the uptake of heat pump technology by the UK domestic sector , 2010 .

[7]  J. T. Beard,et al.  Thermal performance of horizontal closed-loop ground-coupled heat pump systems using flowable-fill , 1996, IECEC 96. Proceedings of the 31st Intersociety Energy Conversion Engineering Conference.

[8]  Saffa Riffat,et al.  Ground source heat pump––description and preliminary results of the Eco House system , 2004 .

[9]  Galip Temir,et al.  Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification , 2009 .

[10]  M. Piechowski Heat and mass transfer model of a ground heat exchanger: validation and sensitivity analysis , 1998 .

[11]  Mustafa Inalli,et al.  Numerical and experimental analysis of a horizontal ground-coupled heat pump system , 2007 .

[12]  Ahmet Koyun,et al.  Experimental study of heat transfer of buried finned pipe for ground source heat pump applications , 2009 .