Configurable Automatic Detection and Registration of Fiducial Frames for Device-to-Image Registration in MRI-Guided Prostate Interventions

We propose a novel automatic fiducial frame detection and registration method for device-to-image registration in MRI-guided prostate interventions. The proposed method does not require any manual selection of markers, and can be applied to a variety of fiducial frames, which consist of multiple cylindrical MR-visible markers placed in different orientations. The key idea is that automatic extraction of linear features using a line filter is more robust than that of bright spots by thresholding; by applying a line set registration algorithm to the detected markers, the frame can be registered to the MRI. The method was capable of registering the fiducial frame to the MRI with an accuracy of 1.00 +/- 0.73 mm and 1.41 +/- 1.06 degrees in a phantom study, and was sufficiently robust to detect the fiducial frame in 98% of images acquired in clinical cases despite the existence of anatomical structures in the field of view.

[1]  Thomas Hambrock,et al.  Thirty-Two-Channel Coil 3T Magnetic Resonance-Guided Biopsies of Prostate Tumor Suspicious Regions Identified on Multimodality 3T Magnetic Resonance Imaging: Technique and Feasibility , 2008, Investigative radiology.

[2]  Tom W J Scheenen,et al.  Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance. , 2011, Radiology.

[3]  M. Bock,et al.  Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation , 2008, Magnetic resonance in medicine.

[4]  N. Hata,et al.  An integrated visualization system for surgical planning and guidance using image fusion and an open MR , 2001, Journal of magnetic resonance imaging : JMRI.

[5]  Guido Gerig,et al.  Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images , 1998, Medical Image Anal..

[6]  Gabor Fichtinger,et al.  An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention , 2011, IEEE Transactions on Biomedical Engineering.

[7]  William J Catalona,et al.  Serial biopsy results in prostate cancer screening study. , 2002, The Journal of urology.

[8]  Kemal Tuncali,et al.  In-bore setup and software for 3T MRI-guided transperineal prostate biopsy , 2012, Physics in medicine and biology.

[9]  Majd Alshawa lCL: Iterative closest line A novel point cloud registration algorithm based on linear features , 2007 .

[10]  S. Zangos,et al.  MR-compatible Assistance System for Biopsy in a High-Field-Strength System: Initial Results in Patients with Suspicious Prostate Lesions 1 , 2022 .

[11]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  Russell H. Taylor,et al.  A Single Image Registration Method for CT Guided Interventions , 1999, MICCAI.