The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study.

AIMS A detailed appreciation of the left atrial/pulmonary venous (LA/PV) anatomy may be important in improving the safety and success of catheter ablation for AF. The aim of this randomized study was to determine the impact of computed tomographic (CT) integration into an electroanatomic mapping (EAM) system on clinical outcome in patients undergoing catheter ablation for atrial fibrillation (AF). METHODS AND RESULTS Eighty patients with AF were randomized to undergo first-time wide encirclement of ipsilateral PV pairs using EAM alone (40 patients) or with CT (40 patients, Cartomerge). Wide encirclement of the pulmonary veins was performed using irrigated radiofrequency ablation with the electrophysiological endpoint of electrical isolation (EI). The primary endpoint was single-procedure success at 6 month follow up. Acute and long-term procedural outcomes were also determined. There was no significant difference in single procedure success between EAM (56%) and cavotricuspid isthmus image (CTI) (50%) groups (P = 0.9). Acute procedural outcomes (EI, PV reconnection, sinus rhythm restored by ablation in persistent AF), fluoroscopy, and procedure durations (EI of right PVs, EI of left PVs, total) did not differ significantly between EAM and CTI groups. CONCLUSION Image integration to guide catheter ablation for AF did not significantly improve the clinical outcome. Achieving PV EI is the critical determinant of procedural success rather than the mapping tools used to achieve it.

[1]  R. Schilling,et al.  Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[2]  D. Sánchez-Quintana,et al.  Architecture of the pulmonary veins: relevance to radiofrequency ablation , 2001, Heart.

[3]  Atul Verma,et al.  Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein Conduction , 2005, Circulation.

[4]  Sabine Ernst,et al.  Complete Isolation of Left Atrium Surrounding the Pulmonary Veins: New Insights From the Double-Lasso Technique in Paroxysmal Atrial Fibrillation , 2004, Circulation.

[5]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[6]  Douglas Packer,et al.  Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation , 2005, Circulation.

[7]  M. Earley,et al.  Catheter ablation of permanent atrial fibrillation: medium term results , 2005, Heart.

[8]  M. Coceani,et al.  Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Clinical Outcome and Mechanisms of Subsequent Arrhythmias , 2006, Journal of cardiovascular electrophysiology.

[9]  Kim Rajappan,et al.  The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[10]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[11]  Xingpeng Liu,et al.  Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter Technique , 2005, Circulation.

[12]  Gabriele Vicedomini,et al.  Circumferential Radiofrequency Ablation of Pulmonary Vein Ostia A New Anatomic Approach for Curing Atrial Fibrillation , 2000 .

[13]  Burr Hall,et al.  Catheter Ablation for Paroxysmal Atrial Fibrillation: Segmental Pulmonary Vein Ostial Ablation Versus Left Atrial Ablation , 2003, Circulation.

[14]  Henry R. Halperin,et al.  Pulmonary Vein Anatomy in Patients Undergoing Catheter Ablation of Atrial Fibrillation: Lessons Learned by Use of Magnetic Resonance Imaging , 2003, Circulation.

[15]  Prashanthan Sanders,et al.  Electrical Remodeling of the Atria in Congestive Heart Failure: Electrophysiological and Electroanatomic Mapping in Humans , 2003, Circulation.

[16]  R. Schilling,et al.  Image integration for atrial fibrillation ablation--pearls and pitfalls. , 2007, Heart rhythm.

[17]  Claudia Herrera,et al.  Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?: Results From a Prospective Randomized Study , 2007, Circulation.

[18]  Hugh Calkins,et al.  Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[19]  J Clémenty,et al.  Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins , 2000, Circulation.

[20]  H. Halperin,et al.  Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations , 2006, Circulation.

[21]  F. Sacher,et al.  Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Critical Structures for Termination , 2005, Journal of cardiovascular electrophysiology.

[22]  Mandeep Bhargava,et al.  Pre-existent left atrial scarring in patients undergoing pulmonary vein antrum isolation: an independent predictor of procedural failure. , 2005, Journal of the American College of Cardiology.

[23]  Elia Biganzoli,et al.  Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation , 2005, Circulation. Arrhythmia and electrophysiology.

[24]  J Clémenty,et al.  Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. , 2000, Circulation.

[25]  S. Ernst,et al.  Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary Veins: Lessons From Double Lasso Technique , 2005, Circulation.