Using a dual-tree complex wavelet transform for denoising an optical coherence tomography angiography blood vessel image

High image quality is of great importance for precise diagnosis and therapeutics of eye disease in clinic. A human retina OCT angiography (OCTA) image can be extracted from multiple OCT B-scans to visualize the distribution of blood vessels. However, OCTA suffer from the degeneration of image quality due to inherent Gaussian noise of the OCT system while the blood vessel’s signal is extracted. The degeneration of the noise in OCTA image will be more conducive to the evaluation of abnormal and normal blood vessels in the human eye. To precisely assist diagnosis and therapeutics in clinic by reducing the Gaussian noise in the OCTA image, an OCTA image denoising method is proposed based on the dual-tree complex wavelet transform and bilateral shrinking Bayes frame. Initially, OCTA images are extracted from the raw data based on the optical microangiography algorithm. Then, the image is decomposed into the wavelet domain using the dual-tree complex wavelet transform. The signal and noise among different wavelet scale layers are separated on the basis of the Bayesian posterior probability. Finally, the inverse wavelet transform is employed to reconstruct the denoised image. Through the noise reduction process of the algorithm, the PSNR and CNR of the OCTA image are increased by 49.15% and 47.91%, respectively. According to the results, the wavelet transform can effectively separate the blood flow signal and noise in processing the OCTA signal, which will provide an effective image processing method for the clinical evaluation requiring high-quality OCTA images.

[1]  Michał Chlebiej,et al.  Quality improvement of OCT angiograms with elliptical directional filtering. , 2019, Biomedical optics express.

[2]  Rui Bernardes,et al.  Improved Adaptive Complex Diffusion Despeckling Filter References and Links , 2022 .

[3]  Utku Baran,et al.  Motion artifact and background noise suppression on optical microangiography frames using a naïve Bayes mask. , 2014, Applied optics.

[4]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[5]  M. V. Cicinelli,et al.  QUANTITATIVE ANALYSIS OF OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN ADULT-ONSET FOVEOMACULAR VITELLIFORM DYSTROPHY , 2017, Retina.

[6]  Jun Cheng,et al.  Universal digital filtering for denoising volumetric retinal OCT and OCT angiography in 3D shearlet domain. , 2020, Optics letters.

[7]  M. Larsen,et al.  Enhanced optical coherence tomography imaging by multiple scan averaging , 2005, British Journal of Ophthalmology.

[8]  Martin F. Kraus,et al.  Split-spectrum amplitude-decorrelation angiography with optical coherence tomography , 2012, Optics express.

[9]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[10]  Ruikang K. Wang,et al.  Quantifying Retinal Microvascular Changes in Uveitis Using Spectral-Domain Optical Coherence Tomography Angiography. , 2016, American journal of ophthalmology.

[11]  Akihito Uji,et al.  Multiple enface image averaging for enhanced optical coherence tomography angiography imaging , 2018, Acta ophthalmologica.

[12]  Robert J Zawadzki,et al.  Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique. , 2009, Optics express.

[13]  Joachim Hornegger,et al.  Wavelet denoising of multiframe optical coherence tomography data , 2012, Biomedical optics express.

[14]  Yue Wu,et al.  Generating retinal flow maps from structural optical coherence tomography with artificial intelligence , 2018, Scientific Reports.

[15]  Peijun Gong,et al.  Optical coherence tomography angiography for longitudinal monitoring of vascular changes in human cutaneous burns , 2016, Experimental dermatology.

[16]  Ruikang K. Wang,et al.  In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography. , 2008, Optics express.

[17]  Andreas Maier,et al.  A deep learning based pipeline for optical coherence tomography angiography , 2019, Journal of biophotonics.

[18]  Jiliu Zhou,et al.  Simultaneous denoising and super-resolution of optical coherence tomography images based on generative adversarial network. , 2019, Optics express.

[19]  Massoud Motamedi,et al.  Retinal optical coherence tomography image enhancement via shrinkage denoising using double-density dual-tree complex wavelet transform , 2012, Journal of biomedical optics.

[20]  Richard Baraniuk,et al.  The Dual-tree Complex Wavelet Transform , 2007 .

[21]  I. Selesnick,et al.  Bivariate shrinkage with local variance estimation , 2002, IEEE Signal Processing Letters.

[22]  Xi Liu,et al.  Adaptive classifier allows enhanced flow contrast in OCT angiography using a histogram-based motion threshold and 3D Hessian analysis-based shape filtering. , 2017, Optics letters.

[23]  Jay S Duker,et al.  A review of optical coherence tomography angiography (OCTA) , 2015, International Journal of Retina and Vitreous.

[24]  Shahab Chitchian,et al.  Denoising during optical coherence tomography of the prostate nerves via wavelet shrinkage using dual-tree complex wavelet transform. , 2009, Journal of biomedical optics.

[25]  Peyman Milanfar,et al.  Statistical Models of Signal and Noise and Fundamental Limits of Segmentation Accuracy in Retinal Optical Coherence Tomography , 2018, IEEE Transactions on Medical Imaging.

[26]  M. Elad,et al.  $rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse Representation , 2006, IEEE Transactions on Signal Processing.

[27]  Ruikang K. Wang,et al.  High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography. , 2010, Journal of biomedical optics.

[28]  I. Johnstone,et al.  Ideal spatial adaptation by wavelet shrinkage , 1994 .

[29]  Ruikang K. Wang,et al.  Three dimensional optical angiography. , 2007, Optics express.

[30]  Ruikang K. Wang,et al.  Optical coherence tomography correlates multiple measures of tissue damage following acute burn injury. , 2019, Quantitative imaging in medicine and surgery.

[31]  Ruikang K. Wang,et al.  Optical coherence tomography based angiography [Invited]. , 2017, Biomedical optics express.