Direct analysis of melamine in complex matrices using a handheld mass spectrometer.

A low temperature plasma ambient ionization source, coupled to a portable mass spectrometer (Mini 10.5), is used for the determination of melamine contamination in whole milk and related materials. Thermally assisted desorption and ionization of the analyte was achieved with the plasma probe. The small size, low power consumption and capability for direct sampling without pretreatment makes plasma ionization an appropriate ionization method for use with a handheld mass spectrometer. The standard discontinuous atmospheric pressure interface used to connect atmospheric pressure ion sources to mass spectrometers (Gao et al., Anal. Chem., 2008, 80, 4026-4032) was modified by using supplementary pumping to increase the ion transfer efficiency. Whole milk, fish, milk powder and other complex matrices spiked with melamine were placed on glass slides close to the vacuum inlet and analyzed without sample pretreatment. Quantitation in complex matrices was achieved using MS/MS of protonated melamine m/z 127 to yield the characteristic fragment ion of m/z 85. Analysis rates of two samples per minute, levels of melamine as low as 250 ng/mL in whole milk (below the regulatory level in the US of 1 ppm (1 microg/mL) or the European level of 2.5 ppm (microg/mL)), a linear dynamic range of 0.5-50 microg/mL and a relative standard deviation of ca. 7.6-16.2% were achieved. The importance of melamine to public health and the prior lack of a rapid, sensitive and yet highly specific field analysis method add to the relevance of this study.

[1]  Shuiping Yang,et al.  Detection of melamine in milk products by surface desorption atmospheric pressure chemical ionization mass spectrometry. , 2009, Analytical chemistry.

[2]  R. Cooks,et al.  Ambient Mass Spectrometry , 2006, Science.

[3]  M. Filigenzi,et al.  The determination of melamine in muscle tissue by liquid chromatography/tandem mass spectrometry. , 2007, Rapid communications in mass spectrometry : RCM.

[4]  Renate Reimschuessel,et al.  Determination and confirmation of melamine residues in catfish, trout, tilapia, salmon, and shrimp by liquid chromatography with tandem mass spectrometry. , 2008, Journal of agricultural and food chemistry.

[5]  R. Cooks,et al.  Rapid hydrocarbon analysis using a miniature rectilinear ion trap mass spectrometer. , 2008, The Analyst.

[6]  Zheng Ouyang,et al.  Ambient mass spectrometry with a handheld mass spectrometer at high pressure. , 2007, Analytical chemistry.

[7]  J. Sunner,et al.  Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids. , 2005, Rapid communications in mass spectrometry : RCM.

[8]  大房 健 基礎講座 電気泳動(Electrophoresis) , 2005 .

[9]  Renato Zenobi,et al.  Rapid detection of melamine in untreated milk and wheat gluten by ultrasound-assisted extractive electrospray ionization mass spectrometry (EESI-MS). , 2009, Chemical communications.

[10]  B. Musselman,et al.  Direct analysis in real time for reaction monitoring in drug discovery. , 2007, Analytical chemistry.

[11]  R. Cooks,et al.  Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization , 2004, Science.

[12]  R. R. Steiner,et al.  Validation of the Direct Analysis in Real Time Source for Use in Forensic Drug Screening , 2009, Journal of forensic sciences.

[13]  D. Barrett,et al.  Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry. , 2007, Analytical chemistry.

[14]  R. Kissling,et al.  Routine analysis of proteins by Kjeldahl and Dumas methods: review and interlaboratory study using dairy products. , 1998, Journal of AOAC International.

[15]  Zheng Ouyang,et al.  Direct detection of benzene, toluene, and ethylbenzene at trace levels in ambient air by atmospheric pressure chemical ionization using a handheld mass spectrometer , 2010, Journal of the American Society for Mass Spectrometry.

[16]  M. Ibáñez,et al.  Residue determination of cyromazine and its metabolite melamine in chard samples by ion-pair liquid chromatography coupled to electrospray tandem mass spectrometry , 2005 .

[17]  G. V. Van Berkel,et al.  Automated sampling and imaging of analytes separated on thin-layer chromatography plates using desorption electrospray ionization mass spectrometry. , 2006, Analytical chemistry.

[18]  Zheng Ouyang,et al.  Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface. , 2008, Analytical chemistry.

[19]  Meng-Qiang Zhao,et al.  Development of a dielectric barrier discharge ion source for ambient mass spectrometry , 2007, Journal of the American Society for Mass Spectrometry.

[20]  Weiguo Wang,et al.  Atmospheric pressure air direct current glow discharge ionization source for ion mobility spectrometry. , 2008, Analytical chemistry.

[21]  K. Peltonen,et al.  Determination of melamine in air by high-performance liquid chromatography with ultraviolet detection. , 1987, Journal of chromatography.

[22]  Huanwen Chen,et al.  Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry. , 2005, Chemical communications.

[23]  Zheng Ouyang,et al.  Low-temperature plasma probe for ambient desorption ionization. , 2008, Analytical chemistry.

[24]  Ambient aerodynamic ionization source for remote analyte sampling and mass spectrometric analysis. , 2008, Analytical chemistry.

[25]  Renate Reimschuessel,et al.  Identification and characterization of toxicity of contaminants in pet food leading to an outbreak of renal toxicity in cats and dogs. , 2008, Toxicological sciences : an official journal of the Society of Toxicology.

[26]  Linda S Aston,et al.  Diagnostic determination of melamine and related compounds in kidney tissue by liquid chromatography/tandem mass spectrometry. , 2008, Journal of agricultural and food chemistry.

[27]  Xingguo Chen,et al.  Determination of melamine in dairy products, fish feed, and fish by capillary zone electrophoresis with diode array detection. , 2009, Journal of agricultural and food chemistry.

[28]  R. Cooks,et al.  High-throughput trace melamine analysis in complex mixtures. , 2009, Chemical communications.

[29]  R. A. Yokley,et al.  Analytical method for the determination of cyromazine and melamine residues in soil using LC-UV and GC-MSD. , 2000, Journal of agricultural and food chemistry.

[30]  Adam M. Hawkridge,et al.  Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector , 2007, Journal of the American Society for Mass Spectrometry.

[31]  Zheng Ouyang,et al.  Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer. , 2004, Analytical chemistry.

[32]  R. Graham Cooks,et al.  Ambient desorption ionization mass spectrometry , 2008 .

[33]  K. Yuen,et al.  Analysis of melamine cyanurate in urine using matrix-assisted laser desorption/ionization mass spectrometry. , 2009, Analytical chemistry.

[34]  L. B. Perkins,et al.  Determination of melamine in pet food by enzyme immunoassay, high-performance liquid chromatography with diode array detection, and ultra-performance liquid chromatography with tandem mass spectrometry. , 2008, Journal of AOAC International.

[35]  R. Cody Observation of molecular ions and analysis of nonpolar compounds with the direct analysis in real time ion source. , 2009, Analytical chemistry.

[36]  R. Cody,et al.  Versatile new ion source for the analysis of materials in open air under ambient conditions. , 2005, Analytical chemistry.

[37]  Michael R. Webb,et al.  Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds. , 2008, Analytical chemistry.

[38]  A. Godoi,et al.  Trace analysis of benzene, toluene, ethylbenzene and xylene isomers in environmental samples by low-pressure gas chromatography-ion trap mass spectrometry. , 2003, Journal of chromatography. A.

[39]  Qingyu Song,et al.  Handheld rectilinear ion trap mass spectrometer. , 2006, Analytical chemistry.

[40]  A. Kong,et al.  Liquid microjunction surface sampling probe electrospray mass spectrometry for detection of drugs and metabolites in thin tissue sections. , 2008, Journal of mass spectrometry : JMS.

[41]  Hao Xin,et al.  Chinese Probe Unmasks High-Tech Adulteration With Melamine , 2008, Science.

[42]  C. Klampfl,et al.  Analysis of melamine resins by capillary zone electrophoresis with electrospray ionization‐mass spectrometric detection , 2005, Electrophoresis.

[43]  W. Cheng,et al.  Determination of urine melamine by validated isotopic ultra-performance liquid chromatography/tandem mass spectrometry. , 2009, Rapid communications in mass spectrometry : RCM.