Review of test methods used for the measurement of hermeticity in packages containing small cavities

This paper presents a critical review of the traditional and newly proposed test methods used for the measurement of hermeticity in packages with very small cavity volumes. Closed-form expressions of the minimum and maximum true leak rates achievable are provided for the helium fine leak test method. These expressions are shown to provide practical guidelines for the accurate testing of hermeticity for ultrasmall packages. A portfolio of hermeticity test methods is also presented outlining the limitations and advantages of each method.

[1]  P. De Moor,et al.  Hermeticity Testing and Failure Analysis of MEMS Packages , 2007, 2007 14th International Symposium on the Physical and Failure Analysis of Integrated Circuits.

[2]  Khalil Najafi,et al.  A high-performance surface-micromachined Pirani gauge in SUMMIT V/spl trade/ , 2005, 18th IEEE International Conference on Micro Electro Mechanical Systems, 2005. MEMS 2005..

[3]  W. Weber,et al.  Using Raman Microscopy to Detect Leaks in Micromechanical Silicon Structures , 1997 .

[4]  Ca Mann,et al.  The back-pressurising technique of leak-testing , 1965 .

[5]  G. Elger,et al.  Optical leak detection for wafer level hermeticity testing , 2004, IEEE/CPMT/SEMI 29th International Electronics Manufacturing Technology Symposium (IEEE Cat. No.04CH37585).

[6]  M. Nese,et al.  New method for testing hermeticity of silicon sensor structures , 1996 .

[7]  J. Davy,et al.  Model calculations for maximum allowable leak rates of hermetic packages , 1975 .

[8]  Djemel Lellouchi,et al.  FTIR spectroscopy for the hermeticity assessment of micro-cavities , 2005, Microelectron. Reliab..

[9]  F. Gueissaz Ultra low leak detection method for MEMS devices , 2005, 18th IEEE International Conference on Micro Electro Mechanical Systems, 2005. MEMS 2005..

[10]  Bongtae Han,et al.  On Ultra-Fine Leak Detection of Hermetic Wafer Level Packages , 2008, IEEE Transactions on Advanced Packaging.

[11]  K. Schjølberg-Henriksen,et al.  Anodic bonding of glass to aluminium , 2006 .

[12]  Marc P.Y. Desmulliez,et al.  Leak detection methods for glass capped and polymer sealed MEMS packaging , 2010, 2010 Symposium on Design Test Integration and Packaging of MEMS/MOEMS (DTIP).

[13]  M. Tencer,et al.  Moisture ingress into nonhermetic enclosures and packages. A quasi-steady state model for diffusion and attenuation of ambient humidity variations , 1994, 1994 Proceedings. 44th Electronic Components and Technology Conference.

[14]  Bongtae Han,et al.  Hermeticity Evaluation of Polymer-Sealed MEMS Packages by Gas Diffusion Analysis , 2009, Journal of Microelectromechanical Systems.

[15]  Karl K. Rink,et al.  Fundamental considerations concerning the detection of gross leaks in bridge-wire initiators , 2006 .

[16]  A. S. Berman,et al.  Flow and Self‐Diffusion of Gases in Capillaries. Part I , 1966 .

[17]  Guoqi Zhang,et al.  Assessment of testing methodologies for thin-film vacuum MEMS packages , 2008 .

[18]  Khalil Najafi,et al.  A High-Perfiwmance Surface-Micromachined Pirani Gauge in SUMMIT FM , 2005 .

[19]  Robert Puers,et al.  A method to evaluate internal cavity pressure of sealed MEMS devices , 2005 .