Noninvasive Detection of Suction in an implantable Rotary Blood Pump Using Neural Networks

Granting those heart failure patients who are recipients of an implantable rotary blood pump (iRBP) greater functionality in daily activities is a key long-term strategy currently being pursued by many research groups. A reliable technique for noninvasive detection of the various pumping states, most notably that of ventricular collapse or suction, is an essential component of this strategy. Presented in this study is such a technique, whereby various indicators are derived from the noninvasive pump feedback signals, and a suitable computational methodology developed to classify the pumping states of interest. Clinical telemetry data from ten implant recipients was categorized (with the aid of trans-oesophageal echocardiography) into the normal and suction states. These data are used to develop a pumping state classifier based on an artificial neural network (ANN). Nine indices, derived from the noninvasive impeller speed signal, form the inputs to this ANN classifier. During validation, the resulting ANN classifier achieved a maximum sensitivity of 98.54% (609/618 samples of 5 s in length) and specificity of 99.26% (12,123/12,213 samples) for correct detection of the suction state. The ability to detect the suction state with such a high degree of accuracy provides a critical parameter both for control strategy development, and for clinical care of the implant recipient.

[1]  R. Benkowski,et al.  Suction Detection for the MicroMed DeBakey Left Ventricular Assist Device , 2005, ASAIO journal.

[2]  James F. Antaki,et al.  Control of rotary heart assist devices , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[3]  Georg Wieselthaler,et al.  Development of a suction detection system for axial blood pumps. , 2004, Artificial organs.

[4]  K Araki,et al.  The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. , 2001, Artificial organs.

[5]  H Schima,et al.  An artificial neural network-based noninvasive detector for suction and left atrium pressure in the control of rotary blood pumps: an in vitro study. , 1995, Artificial organs.

[6]  Georg Wieselthaler,et al.  Advanced suction detection for an axial flow pump. , 2006, Artificial organs.

[7]  Marwan A. Simaan,et al.  A discriminant-analysis-based suction detection system for rotary blood pumps , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  A. W. Hall,et al.  Physiologic control of cardiac assist devices. , 1996, Artificial organs.

[9]  Nigel H Lovell,et al.  Identification and classification of physiologically significant pumping states in an implantable rotary blood pump. , 2006, Artificial organs.

[10]  K Araki,et al.  Sensorless controlling method for a continuous flow left ventricular assist device. , 2000, Artificial organs.

[11]  J.R. Boston,et al.  Combination of data approaches to heuristic control and fault detection [heart assist devices] , 2000, Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162).

[12]  S Takatani,et al.  Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow. , 1999, Artificial organs.

[13]  J R Boston,et al.  Controller for an Axial Flow Blood Pump. , 1996, Artificial organs.

[14]  M. Yoshizawa,et al.  Detection and Avoiding Ventricular Suction of Ventricular Assist Devices , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.