Impedance Pharyngography to Assess Swallowing Function

We evaluated impedance pharyngography (IPG), a new method to assess swallowing function based on changes in the electrical impedance of the neck during swallowing. The electrical impedance of the neck, recorded by the 4-electrode method, changed with the equivalent cross-sectional area of the route of the electric current due to reflex activities of related organs during swallowing. IPG waveforms accurately recorded the swallowing process, therefore. We recommend IPG for assessing swallowing function because we expect IPG to provide the following advantages over conventional diagnostic techniques: it is a quantitative method that allows for the objective assessment of swallowing function; it is a simple procedure that is convenient for the patient and could be used for screening; it is inexpensive and non-invasive, so could be performed repeatedly in situations such as rehabilitation; and it uses highly portable equipment suitable for community use.

[1]  Yoshitake Yamamoto,et al.  Measurement of reaction time in agility using bioelectrical impedance , 1992, Systems and Computers in Japan.

[2]  J. Logemann,et al.  Manual for the videofluorographic study of swallowing , 1986 .

[3]  L. E. Baker,et al.  THE MEASUREMENT OF RESPIRATORY VOLUMES IN ANIMALS AND MAN WITH USE OF ELECTRICAL IMPEDANCE , 1970 .

[4]  Clifford D. Ferris,et al.  Four‐Electrode Null Techniques for Impedance Measurement with High Resolution , 1968 .

[5]  Ramon Bragós,et al.  Electrical bioimpedance methods: applications to medicine and biotechnology , 1999 .

[6]  T. Nakamura,et al.  Fundamental characteristics of human limb electrical impedance for biodynamic analysis , 2006, Medical and Biological Engineering and Computing.

[7]  J. Thompson,et al.  Patterns of electrical skin resistance following sympathectomy. , 1950, Archives of surgery.

[8]  K. Yamakoshi,et al.  Evaluation of the Parallel Conductor Theory for Measuring Human Limb Blood Flow by Electrical Admittance Plethysmography , 1982, IEEE Transactions on Biomedical Engineering.

[9]  M. Gildemeister Über elektrischen Widerstand, Kapazität und Polarisation der Haut , 1919, Pflüger's Archiv für die gesamte Physiologie des Menschen und der Tiere.

[10]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[11]  Martin W. Donner,et al.  Anatomy and physiology of the pharynx , 2005, Gastrointestinal Radiology.

[12]  H. Schwan,et al.  Specific Resistance of Body Tissues , 1956, Circulation research.

[13]  J W Moore,et al.  Membranes, ions, and impulses: Dedication to Kacy Cole , 1975 .

[14]  S. Markovich International conference on bioelectrical impedance. , 1970 .

[15]  S. C. Kim,et al.  Optimum electrode configuration for detection of arm movement using bio-impedance , 2003, Medical and Biological Engineering and Computing.

[16]  Leopold Na,et al.  Swallowing, ingestion and dysphagia: a reappraisal. , 1983 .

[17]  R. Patterson,et al.  Development and evaluation of an impedance cardiac output system. , 1966, Aerospace medicine.

[18]  K. Yamamoto,et al.  Characterisation of steady-state and transient responses of transcutaneouspO2 andpCO2 by mass spectrometry , 1985, Medical and Biological Engineering and Computing.

[19]  H. Schwan,et al.  The Practical Success of Impedance Techniques from an Historical Perspective , 1999 .

[20]  T. Yamamoto,et al.  Impedance plethysmography for blood flow measurements in human limbs , 2006, Medical and Biological Engineering and Computing.

[21]  K. Cole ELECTRIC IMPEDANCE OF SUSPENSIONS OF ARBACIA EGGS , 1928, The Journal of general physiology.

[22]  J. Logemann,et al.  Evaluation and treatment of swallowing disorders , 1983 .