Rapid whole-blood microassay using flow cytometry for measuring neutrophil phagocytosis

A simple flow cytometric method (FCM) for measuring phagocytosis of Staphylococcus aureus by human neutrophils (polymorphonuclear leukocytes [PMNs]) is described. This assay utilizes 100 microliters of EDTA-anticoagulated whole blood and a simplified method of fluorescently labeling bacteria. A commercially available whole-blood lysing reagent allows for the removal of erythrocytes and the exclusion of external free or adherent bacteria. Phagocytized bacteria are unaffected by this reagent, so PMNs containing internalized bacteria can be easily identified by FCM. Advantages of this method include the following: (i) small sample size, (ii) no requirement for PMN separation, (iii) rapid reliable method of labeling the bacteria, (iv) ability to distinguish between adherent bacteria and those which are actually internalized, (v) avoidance of vital dyes as quenching agents, and (vi) ability to fix cells and store for future FCM analysis.

[1]  P. Courtoy,et al.  Staphylococcus aureus phagocytosis. A new cytofluorometric method using FITC and paraformaldehyde. , 1989, Journal of immunological methods.

[2]  A. Fattorossi,et al.  New, simple flow cytometry technique to discriminate between internalized and membrane-bound particles in phagocytosis. , 1989, Cytometry.

[3]  Yohnosuke Kobayashi,et al.  Simultaneous measurement by flow cytometry of phagocytosis and hydrogen peroxide production of neutrophils in whole blood. , 1989, Journal of immunological methods.

[4]  R. Axtell Evaluation of the patient with a possible phagocytic disorder. , 1988, Hematology/oncology clinics of North America.

[5]  S. Johansson,et al.  The use of fluorescence quenching in flow cytofluorometry to measure the attachment and ingestion phases in phagocytosis in peripheral blood without prior cell separation. , 1987, Journal of immunological methods.

[6]  R. Bjerknes,et al.  Phagocytosis by human leukocytes, phagosomal pH and degradation of seven species of bacteria measured by flow cytometry. , 1985, Journal of medical microbiology.

[7]  R. Bjerknes Flow cytometric assay for combined measurement of phagocytosis and intracellular killing of Candida albicans. , 1984, Journal of immunological methods.

[8]  O. Laerum,et al.  Simultaneous measurement of phagocytosis and phagosomal pH by flow cytometry: role of polymorphonuclear neutrophilic leukocyte granules in phagosome acidification. , 1983, Cytometry.

[9]  J. Hed The extinction of fluorescence by crystal violet and its use to differentiate between attached and ingested microorganisms in phagocytosis , 1977 .

[10]  O. Laerum,et al.  Flow cytometry for the study of phagocyte functions. , 1989, Reviews of infectious diseases.

[11]  J. Alexander,et al.  Studies on the binding of C3b-coated microspheres to human neutrophils. , 1985, Journal of immunological methods.

[12]  M. Seeds,et al.  Independent stimulation of membrane potential changes and the oxidative metabolic burst in polymorphonuclear leukocytes. , 1985, Blood.

[13]  J. Verhoef,et al.  Infections in the immunocompromised host : pathogenesis, prevention, and therapy : proceedings of the First International Symposium on Infections in the Immunocomprised Host held in Veldhoven, The Netherlands, 1-5 June, 1980 , 1980 .