Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

AIMS Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. METHODS AND RESULTS All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P < 0.001). The 4-year survival rate of device battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P < 0.001). The difference in battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. CONCLUSION There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

[1]  J. Daubert,et al.  The effect of cardiac resynchronization on morbidity and mortality in heart failure. , 2005, The New England journal of medicine.

[2]  Wojciech Zareba,et al.  Cardiac-resynchronization therapy for the prevention of heart-failure events. , 2009, The New England journal of medicine.

[3]  M. Metra,et al.  Long-term survival in patients undergoing cardiac resynchronization therapy: the importance of performing atrio-ventricular junction ablation in patients with permanent atrial fibrillation , 2008, European heart journal.

[4]  M. Chung,et al.  Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures: Results From the REPLACE Registry , 2010, Circulation.

[5]  G. Nickenig,et al.  Real‐World Data on the Lifespan of Implantable Cardioverter‐Defibrillators Depending on Manufacturers and the Amount of Ventricular Pacing , 2012, Journal of cardiovascular electrophysiology.

[6]  D. DeMets,et al.  Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. , 2004, The New England journal of medicine.

[7]  A. Krahn,et al.  Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories. , 2006, JAMA.

[8]  SumChe Man,et al.  Implantable cardioverter-defibrillator longevity under clinical circumstances: an analysis according to device type, generation, and manufacturer. , 2012, Heart rhythm.

[9]  J. Nielsen,et al.  Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients , 2011, European heart journal.

[10]  F. Regoli,et al.  Cardiac resynchronization therapy in heart failure patients with atrial fibrillation , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[11]  Giuseppe Boriani,et al.  Longevity of implantable cardioverter-defibrillators: implications for clinical practice and health care systems. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[12]  M. Chung,et al.  Cardiovascular Implantable Electronic Device Replacement Infections and Prevention: Results from the REPLACE Registry , 2012, Pacing and clinical electrophysiology : PACE.

[13]  C. Sticherling,et al.  Longevity of implantable cardioverter-defibrillators, influencing factors, and comparison to industry-projected longevity. , 2009, Heart rhythm.