Computational flow optimization of rotary blood pump components.

In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically the shape of an initial candidate blood path, according to a variety of desired fluid dynamic criteria, including shear stress, vorticity/circulation, and viscous dissipation. Preliminary results have led to both intuitive and nonintuitive transformations of the initial blood flow paths for both internal and external flows. This application of computer design optimization offers the ability to explore a much broader design space much more efficiently than would be possible with traditional parametric methods. It is believed that this computer tool can assist developers of rotary blood pumps in designing blood-wetted components that minimize thrombosis and hemolysis while simultaneously providing maximum flow performance.

[1]  R L Kormos,et al.  Evaluation of Bioprosthetic Valve‐Associated Thrombus in Ventricular Assist Device Patients , 1993, Circulation.

[2]  M Umezu,et al.  A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex. , 1992, ASAIO journal.

[3]  Carlos E. Orozco,et al.  Massively parallel aerodynamic shape optimization , 1992 .

[4]  Y Nosé,et al.  Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results. , 1994, Artificial organs.

[5]  Edward F. Leonard,et al.  Principles of Cardiovascular Device Design , 1993 .

[6]  H Reul,et al.  Shear Stress Related Blood Damage along the Cusp of a Tri-Leaflet Prosthetic Valve , 1991, The International journal of artificial organs.

[7]  U Losert,et al.  Minimization of Hemolysis in Centrifugal Blood Pumps: Influence of Different Geometries , 1993, The International journal of artificial organs.

[8]  Oktay Baysal,et al.  Three-dimensional aerodynamic shape optimization using discrete sensitivity analysis , 1996 .

[9]  J D Hellums,et al.  Red blood cell damage by shear stress. , 1972, Biophysical journal.

[10]  James F. Antaki,et al.  Shape optimization of Navier-Stokes flows with application to optimal design of artificial heart components , 1994 .

[11]  R. Schistek Various Designs of Nonpulsatile Blood Pumps , 1989 .

[12]  G Damm,et al.  An ultimate, compact, seal-less centrifugal ventricular assist device: Baylor C-Gyro pump. , 1994, Artificial organs.

[13]  R. Opitz,et al.  A Couette viscometer for short time shearing of blood. , 1980, Biorheology.

[14]  Y Nosé,et al.  A fluid dynamic analysis of a rotary blood pump for design improvement. , 2008, Artificial organs.

[15]  K X Qian Haemodynamic approach to reducing thrombosis and haemolysis in an impeller pump. , 1990, Journal of biomedical engineering.