Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system.
暂无分享,去创建一个
Radhe Mohan | Laurence Court | Lei Dong | Lei Dong | R. Mohan | I. Rosen | L. Court | Isaac Rosen | L. Dong
[1] J. Wong,et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.
[2] J. Tsai,et al. Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.
[3] J H Siewerdsen,et al. Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.
[4] C. Fiorino,et al. Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[5] N. Willich,et al. Conformal therapy for pancreatic cancer: variation of organ position due to gastrointestinal distention--implications for treatment planning. , 2002, Radiology.
[6] D. Dearnaley,et al. Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[7] B J Mijnheer,et al. Variability in target volume delineation on CT scans of the breast. , 2001, International journal of radiation oncology, biology, physics.
[8] M van Herk,et al. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.
[9] J Wong,et al. Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors. , 1997, International journal of radiation oncology, biology, physics.
[10] T Haycocks,et al. Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[11] T R Willoughby,et al. Short-course intensity-modulated radiotherapy for localized prostate cancer with daily transabdominal ultrasound localization of the prostate gland. , 2000, International journal of radiation oncology, biology, physics.
[12] D. Yan,et al. Organ/patient geometric variation in external beam radiotherapy and its effects. , 2001, Medical physics.
[13] C. Ling,et al. Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.
[14] B W Corn,et al. Respiration-induced motion of the kidneys in whole abdominal radiotherapy: implications for treatment planning and late toxicity. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[15] K. Langen,et al. Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.
[16] A. E. Saarnak,et al. Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[17] T E Schultheiss,et al. Ultrasound-based stereotactic guidance in prostate cancer--quantification of organ motion and set-up errors in external beam radiation therapy. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[18] M. V. van Herk,et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.
[19] Arjan Bel,et al. Definition of gross tumor volume in lung cancer: inter-observer variability. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[20] T. Mackie,et al. Registration of synthetic tomographic projection data sets using cross-correlation , 1998, Physics in medicine and biology.
[21] S. Zhou,et al. Differences in gross target volumes on contrast vs. noncontrast CT scans utilized for conformal radiation therapy treatment planning for prostate carcinoma. , 1998, International journal of radiation oncology, biology, physics.
[22] A. Hanlon,et al. Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer. , 2000, Urology.
[23] G J Kutcher,et al. Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate. , 1997, International journal of radiation oncology, biology, physics.
[24] James M Balter,et al. Daily targeting of intrahepatic tumors for radiotherapy. , 2002, International journal of radiation oncology, biology, physics.
[25] Hiroshi Onishi,et al. A new irradiation unit constructed of self-moving gantry-CT and linac. , 2003, International journal of radiation oncology, biology, physics.
[26] J. Kapatoes,et al. Megavoltage CT image reconstruction during tomotherapy treatments. , 2000, Physics in medicine and biology.
[27] H Shirato,et al. Magnetic resonance imaging system for three-dimensional conformal radiotherapy and its impact on gross tumor volume delineation of central nervous system tumors. , 2001, International journal of radiation oncology, biology, physics.
[28] K L Lam,et al. Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.
[29] Patrick A Kupelian,et al. Preliminary observations on biochemical relapse-free survival rates after short-course intensity-modulated radiotherapy (70 Gy at 2.5 Gy/fraction) for localized prostate cancer. , 2002, International journal of radiation oncology, biology, physics.
[30] R Mohan,et al. A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans. , 1996, International journal of radiation oncology, biology, physics.
[31] J O Deasy,et al. Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.
[32] Mageras,et al. Control, Correction, and Modeling of Setup Errors and Organ Motion. , 1995, Seminars in radiation oncology.
[33] Harry Keller,et al. Optimal stochastic correction strategies for rigid-body target motion. , 2003, International journal of radiation oncology, biology, physics.
[34] E. B. Butler,et al. Prostate immobilization using a rectal balloon , 2002, Journal of applied clinical medical physics.
[35] T E Schultheiss,et al. A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.
[36] M van Herk,et al. A general methodology for three-dimensional analysis of variation in target volume delineation. , 1999, Medical physics.
[37] D. Gladstone,et al. A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy. , 1997, International journal of radiation oncology, biology, physics.
[38] J. Wong,et al. Estimating the dose variation in a volume of interest with explicit consideration of patient geometric variation. , 2000, Medical physics.
[39] G T Chen,et al. Initial clinical experience with a video-based patient positioning system. , 1999, International journal of radiation oncology, biology, physics.
[40] H Shirato,et al. Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.
[41] M van Herk,et al. Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.
[42] M. V. van Herk,et al. Irradiation of paranasal sinus tumors, a delineation and dose comparison study. , 2002, International journal of radiation oncology, biology, physics.
[43] Randall K Ten Haken,et al. Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.
[44] K Lam,et al. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. , 1995, International journal of radiation oncology, biology, physics.
[45] H Shirato,et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.
[46] H. Shirato,et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.
[47] J Wong,et al. The use of adaptive radiation therapy to reduce setup error: a prospective clinical study. , 1998, International journal of radiation oncology, biology, physics.
[48] Lei Dong,et al. Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.
[49] Kamil M Yenice,et al. CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization. , 2003, International journal of radiation oncology, biology, physics.
[50] E. Larsen,et al. A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.
[51] M van Herk,et al. Target margins for random geometrical treatment uncertainties in conformal radiotherapy. , 1996, Medical physics.
[52] Shinichi Shimizu,et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[53] T. Mackie,et al. Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.
[54] Gary A Ezzell,et al. Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy. , 2001, International journal of radiation oncology, biology, physics.
[55] Shinichi Shimizu,et al. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. , 2002, International journal of radiation oncology, biology, physics.
[56] G T Chen,et al. Performance of a video-image-subtraction-based patient positioning system. , 1997, International journal of radiation oncology, biology, physics.
[57] A. Brunt,et al. Ultrasound localization of the ovaries for radiation-induced ovarian ablation. , 1999, Clinical oncology (Royal College of Radiologists (Great Britain)).
[58] D A Jaffray,et al. A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.
[59] J H Siewerdsen,et al. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. , 2002, Medical physics.
[60] G J Kutcher,et al. Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning. , 1997, International journal of radiation oncology, biology, physics.
[61] James Mechalakos,et al. Development of a semi-automatic alignment tool for accelerated localization of the prostate. , 2003, International journal of radiation oncology, biology, physics.
[62] Michael G. Herman,et al. CLINICAL USE OF ON-LINE PORTAL IMAGING FOR DAILY PATIENT TREATMENT VERIFICATION , 1994 .
[63] P J Keall,et al. A method to predict the effect of organ motion and set-up variations on treatment plans. , 1999, Australasian physical & engineering sciences in medicine.
[64] P J Reckwerdt,et al. Megavoltage CT imaging as a by-product of multileaf collimator leakage. , 2000, Physics in medicine and biology.
[65] A. Boyer,et al. An investigation of a video-based patient repositioning technique. , 2002, International journal of radiation oncology, biology, physics.
[66] D A Jaffray,et al. The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.
[67] J C Stroom,et al. Internal organ motion in prostate cancer patients treated in prone and supine treatment position. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.