Simple and accurate way for estimating total and segmental arterial compliance: The pulse pressure method

We derived and tested a new, simple, and accurate method to estimate the compliance of the entire arterial tree and parts thereof. The method requires the measurements of pressure and flow and is based on fitting the pulse pressure (systolic minus diastolic pressure) predicted by the two-element windkessel model to the measured pulse pressure. We show that the two-element windkessel model accurately describes the modulus of the input impedance at low harmonics (0–4th) of the heart rate so that the gross features of the arterial pressure wave, including pulse pressure, are accounted for. The method was tested using a distributed nonlinear model of the human systemic arterial tree. Pressure and flow were calculated in the ascending aorta, thoracic aorta, common carotid, and iliac artery. In a linear version of the systemic model the estimated compliance was within 1% of the compliance at the first three locations. In the iliac artery an error of 7% was found. In a nonlinear version, we compared the estimates of compliance with the average compliance over the cardiac cycle and the compliance at the mean working pressure. At the first three locations we found the estimated and “actual” compliance to be within 12% of each other. In the iliac artery the error was larger. We also investigated an increase and decrease in heart rate, a decrease in wall elasticity and exercise conditions. In all cases the estimated total arterial compliance was within 10% of mean compliance. Thus, the errors result mainly from the nonlinearity of the arterial system. Segmental compliance can be obtained by subtraction of compliance determined at two locations.

[1]  W. Hunter,et al.  The Effects of Finite Wave Velocity and Discrete Reflections on Ventricular Loading , 1987 .

[2]  A Noordergraaf,et al.  Estimation of total systemic arterial compliance in humans. , 1990, Journal of applied physiology.

[3]  Kiichi Sagawa,et al.  Effect of nitroglycerin on aortic impedance, diameter, and pulse-wave velocity. , 1988 .

[4]  M. Esler,et al.  Arterial compliance in hypertension. , 1976, Australian and New Zealand journal of medicine.

[5]  M. O'Rourke,et al.  Input Impedance of the Systemic Circulation , 1967, Circulation research.

[6]  M Arditi,et al.  Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements. , 1991, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  D. F. Young,et al.  Computer simulation of arterial flow with applications to arterial and aortic stenoses. , 1992, Journal of biomechanics.

[8]  F. Yin,et al.  Estimating arterial resistance and compliance during transient conditions in humans. , 1989, The American journal of physiology.

[9]  N Westerhof,et al.  Beat-to-beat estimation of peripheral resistance and arterial compliance during pressure transients. , 1987, The American journal of physiology.

[10]  G. Langewouters,et al.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. , 1984, Journal of biomechanics.

[11]  W. Duckworth,et al.  Retroendocytosis of insulin in a cultured kidney epithelial cell line. , 1989, The American journal of physiology.

[12]  G C van den Bos,et al.  Systemic compliance: does it play a role in the genesis of essential hypertension? , 1984, Cardiovascular research.

[13]  F. Yin,et al.  Arterial Compliance — Physiological Viewpoint , 1989 .

[14]  F. Yin,et al.  Estimation of Arterial Compliance , 1987 .

[15]  K Sagawa,et al.  Translation of Otto Frank's paper "Die Grundform des Arteriellen Pulses" Zeitschrift für Biologie 37: 483-526 (1899). , 1990, Journal of molecular and cellular cardiology.

[16]  A. Goldberg,et al.  Maintenance of normal length improves protein balance and energy status in isolated rat skeletal muscles. , 1986, The American journal of physiology.

[17]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[18]  N. Westerhof,et al.  Pressure and Flow Generated by the Left Ventricle against Different Impedances , 1973, Circulation research.

[19]  K P Brin,et al.  Estimation of total arterial compliance: an improved method and evaluation of current methods. , 1986, The American journal of physiology.