New applications of time prism pair in biomedical imaging system

Mechanical delay line has been used in the Michelson interferometer to see the geometry and internal structure of objects. This method has to change the optical path length of a reference arm to match with that of a sample arm. However, its reference mirror must be continuously moved for depth scans, it requires a long time because it is limited by mechanical movement speed. We proposed and demonstrated an high speed optical delay line using two phase modulators in optical coherence tomography for axial scanning. Experimental setup is consist of pulse laser source (center wavelength 1304nm, pulse width 30ps, repetition rate 10GHz), two phase modulators and dispersive shifted fiber. As experimental results, the system has high scanning speed of 120km/s and a high repetition rate of 10MHz were achieved.

[1]  Reginald Birngruber,et al.  Optical coherence-gated imaging of biological tissues , 1996 .

[2]  Chris Xu,et al.  Ultrafast optical delay line by use of a time-prism pair. , 2005, Optics letters.

[3]  Siavash Yazdanfar,et al.  Real-time, high velocity-resolution color Doppler optical coherence tomography. , 2002, Optics letters.

[4]  Zhongping Chen,et al.  Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography. , 1998, Optics express.

[5]  David M. Bloom,et al.  Picosecond time-lenses , 1994 .

[6]  M. Ohtsu,et al.  Ultrahigh Scanning Speed Optical Coherence Tomography Using Optical Frequency Comb Generators , 2001, CLEO 2001.

[7]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[8]  David D. Sampson,et al.  Extended range, rapid scanning optical delay line for biomedical interferometric imaging , 1999 .

[9]  J. Fujimoto,et al.  High-speed phase- and group-delay scanning with a grating-based phase control delay line. , 1997, Optics letters.

[10]  J. Izatt,et al.  Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design. , 1999, Optics letters.

[11]  B. Kolner Space-time duality and the theory of temporal imaging , 1994 .

[12]  L Wang,et al.  Propagation of polarized light in turbid media: simulated animation sequences. , 2000, Optics express.

[13]  Hannes Bleuler,et al.  Air-turbine driven optical low-coherence reflectometry at 28.6-kHz scan repetition rate , 1998 .

[14]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[15]  C. V. Bennett,et al.  Aberrations in temporal imaging , 2001 .